©2020 Advanced Energy Industries, Inc.
The UltraVolt
©
D series of high voltage power supplies is designed to meet the needs of
customers with low-profile, < 13 mm (< 0.511") or < 17.5 mm (< 0.689") applications at 1 to 6 W.
These ultra-compact modules are ideal for detectors that require high-bias voltages and currents
at low ripple. D series PCB-mount high voltage power supplies feature a lightweight design,
state-of-the-art surface-mount technology, and five-sided metal enclosures.
TYPICAL APPLICATIONS
Scanning electron microscopes
(SEM)
Mass spectrometry
Gas chromatography
Spectrometers
Electrostatic chuck (e-chuck)
PZT drivers
Pulse generators
Laser electro-optic modulation
Fiber-optic telecom detectors
Particle physics detectors
Laser range finder detectors
Detectors
Geiger-Muller tubes (GM)
Avalanche photo diodes (APD)
Photo multiplier tubes (PMT)
Photodiodes (PD)
Multi-pixel photon counters (MPPC)
Channel electron multipliers
Silicon detectors (SiD)
Silicon photomultipliers (SiPM)
Image intensifiers (II and IIT)
Microchannel plates (MCP)
Ionization chamber detectors
Thin-film bias
High voltage testing
ATE leakage testing
General laboratory
Bias supplies
ULTRAVOLT D SERIES
MICRO-SIZED HIGH VOLTAGE BIASING SUPPLIES
PRODUCT HIGHLIGHTS
4 models from 0 to 1 kV through
0 to 6 kV
1, 2, 4 or 6 W output power
Low ripple (< 0.02% peak to peak)
Tight line/load regulation
Output current limit protection
Adjustable from 0 to full output
Buffered voltage
and current monitoring
15 or 24 VDC Input
Low profile and lightweight
PCB flat mounting
2 advancedenergy.com
ULTRAVOLT D SERIES
ELECTRICAL SPECIFICATIONS
Parameters Specifications Units
Input Voltage Vin (Pins 2 and 3) 15 VDC ±1.5 V or 24 VDC ±2 V, according to type VDC
Input Current Example for a 15 VDC, output 6000 V, 1 mA model:
inhibition mode: 27 mA at no load and HV = 6000 V 46 mA, at full load < 630 mA
Polarity Fixed positive or negative -
Output Voltage 0 to 1000 0 to 2000 0 to 4000 0 to 6000 VDC
Output Power 1 2 4 6 1 2 4 6 1 2 4 6 1 2 4 6 W
Output Current 1 2 4 6 0.5 1 2 3 0.25 0.5 1 1.5 0.17 0.33 0.67 1 mA
Programming (Pins 4 and 6) Via external voltage source 0 to +5 V ±0.1% at full scale, and input impedance = 94 kΩ -
Max Output Current Iout Limited to 110% of nominal current -
Load Voltage Regulation ±0.01% of full output voltage for no load to full load VDC
Line Voltage Regulation ±0.01% of full output voltage over specified input voltage range VDC
Residual Ripple < 0.02% at full load V pk to pk
Temperature Coefficient 100 PPM/°C
Output HV Monitoring
(Pin 7) {still operating in
inhibition mode}
Analog 0 to +5 V buffered output signal, accuracy ±0.2% -
Output impedance = 1 kΩ
Temperature coefficient: 50 ppm/°C for ≤ 4 kV units, 100 ppm/°C for 6 kV units
Output Current Monitoring
(Pin 5) {still operating in
inhibition mode}
Analog 0 to +5 V buffered output signal, accuracy ±2% -
Output impedance = 1 kΩ
Temperature coefficient: 100 ppm/°C
HV ON/OFF (Pin 1) To disable (opened remote interlock) or enable (closed remote interlock) -
Operating Temperature -10 to +65, full load, max Eout, Tcase temp °C
Storage Temperature -10 to +70 °C
Safeguards Protected against reverse Vin -
Soft start feature: the start is guaranteed with no overshoot
Auto inhibition if case > 75°C
HV setting internally limited to 5.3 V