Limelight by Lutron OEM Integration Guide
Integration Guide
P/N 041684 Rev. B
08/2020
1 Customer Assistance: 1.844.LUTRON1
This document is intended for luminaire/fixture manufacturers who are integrating Limelight by Lutron radio
sensor modules into their luminaires: either LL-EN-INTMOUNT (in-module internal antenna) or LL-EN-
INTMOUNT-A (supplied with an additional fixture-external antenna which enables bypassing Lutron’s RF
validation process) into their luminaires. Both can be installed with or without LL-PIR-L/M/H sensor assemblies.
This guide provides recommendations for electrical and mechanical integration of these parts into a luminaire
and their recommended manufacturing test procedures.
1. Standards
• RoHS Compliant
• FCC15.247 / IC RSS-247
• cULus Recognized for internal mounting at a fixture OEM
• IP65 and UL Wet Locations (LL-PIR-L/M/H) when lens assembly is installed correctly at
fixture manufacturer
• IP65 and UL Wet Locations (external antenna) when antenna is installed correctly at fixture manufacturer
2. Model Numbers
Model Number Description
LL-EN-INTMOUNT Limelight by Lutron Radio Sensor Module with Internal Antenna
LL-EN-INTMOUNT-A Limelight by Lutron Radio Sensor Module with External Antenna
LL-PIR-L Limelight by Lutron PIR Sensor Assembly; for 8 to 15 ft (2.4 to 4.6 m) mounting height
LL-PIR-M Limelight by Lutron PIR Sensor Assembly; for >15 to 30 ft (>4.6 to 9.1 m) mounting height
LL-PIR-H Limelight by Lutron PIR Sensor Assembly; for >30 to 40 ft (>9.1 to 12.2 m) mounting height
3. LL-EN-INTMOUNT Integration
Mechanical Integration
Dimensions shown as: in (mm)
1.24
(31.6)
3.98
(101.1)
2.30
(58.4)
2.30
(58.4)
3.04
(77)
2X 2.25
(57.2)
4X Ø0.164
(4.2)
4X 0.24
(6.1)
Limelight by Lutron OEM Integration Guide
2 Customer Assistance: 1.844.LUTRON1
RF Validation Process
This testing is for RF performance only of LL-EN-INTMOUNT integration (see Section 4. for LL-EN-INTMOUNT-A);
it is the OEM’s responsibility to ensure they follow all other Limelight product specifications
In order to ensure proper Limelight by Lutron system functionality, all lighting fixtures being considered for
LL-EN-INTMOUNT integration will need to be reviewed and validated by Lutron for RF performance. A picture of
the intended LL-EN-INTMOUNT integration or fixture design plan with the intended detailed install location and
orientation specified should be provided to Lutron via limelightOEMintegration@lutron.com. Lutron may request
additional fixture information along with fixture samples for further RF testing. If samples are requested, the
required performance testing may take up to 3 weeks, starting from the day the samples are received by Lutron.
For best RF performance of the LL-EN-INTMOUNT, the antenna should be kept 1.25 in (31.75 mm) from any
metal components (see Top View below) and the product should be elevated 0.25 in (6.35 mm) with standoffs
from a metal surface (see Side View below). The LL-EN-INTMOUNT should not be fully concealed in metal.
Lutron will request fixture samples for testing if either of these installation requirements are violated.
Metal Component Keep-out Area
Dimesions shown as: in (mm)
Top View
Side View
1.25
(31.75)
0.25
(6.35)
1.25
(31.75)
0.25
(6.35)
0.25
(6.35)
0.5
(12.7)
1.25
(31.75)
1.25
(31.75)
Metal Component
Keep-out Area
Metal Component
Keep-out Area
Stand-offs for metal surface
mounting (not required for