Product: 29009
ACIC 600V, 40+G C #16 Str BC, XLPE Ins, PVC Jkt, AIA Armor, Blu PVC Jkt,
90C Dry/Wet CSA HL SUN RES -40C
Product Description
Canadian Instrumentation Cable TC-ACIC 600V, 40+G Conductor 16AWG (7x24) Bare Copper, XLPE Insulation, PVC Inner Jacket, Aluminum Interlock
Armor, Blue PVC Outer Jacket, 90C Dry/Wet CSA HL SUN RES -40C
Technical Specifications
Product Overview
Suitable Applications: Power and Control Aplications up to 600V
Construction Details
Conductor
Element Number of Element Size Stranding Material
Conductor(s) 40 16 AWG 7x24 BC - Bare Copper
Ground Wire 1 16 AWG 7x24 BC - Bare Copper
Insulation
Element Material Nom. Thickness Nom. Insulation Diameter Color Code
Conductor(s) XLP, XLPO, XLPE (Thermoset) 0.030 in (0.76 mm) 0.118 in (3.00 mm) White and Numbered, Black and Numbered
Ground Wire XLP, XLPO, XLPE (Thermoset) 0.030 in (0.76 mm) 0.118 in (3.00 mm) Green
Outer Shield
Material
No Shield
Inner Jacket
Material Nom. Thickness Nom. Diameter Ripcord Color
PVC - Polyvinyl Chloride 0.083 in (2.1 mm) 1.069 in (27.15 mm) Yes Black
Armor
Armor Type & Material Armor Thickness Diameter Over Armor
AIA - Aluminum Interlock Armor 0.034 in (0.86 mm) 1.329 in (33.76 mm)
Table Notes: Seprator -Corrugated Mylar Tape
Outer Jacket
Material Nom. Thickness Nom. Diameter
PVC - Polyvinyl Chloride 0.052 in (1.3 mm) 1.433 in
1.41 in
Overall Cable Diameter (Nominal): 1.410 in
Electrical Characteristics
Electricals
Element Nom. Conductor DCR Max. Current
Conductor(s) 4.2 Ohm/1000ft 3.2 Amps per Conductor at 25ºC
Ground Wire 4.2 Ohm/1000ft (14 Ohm/km) 10 Amps per Conductor at 25ºC
Voltage
Voltage Rating
600 V
Mechanical Characteristics
Temperature
Operating
-40°C To +90°C
Bend Radius
Stationary Min. Installation Min.
16.91 in (429.5 mm) 16.91 in
Max. Pull Tension: 1664 lbs
Bulk Cable Weight: 1016 lbs/1000ft
Standards and Compliance
Environmental Suitability: Indoor, Outdoor, Sunlight Resistance, Burial
Flammability / Reaction to Fire: FT4
CEC / C(UL) Compliance: HL, ACIC
European Directive Compliance: EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
APAC Compliance: China RoHS II (GB/T 26572-2011)
History
Update and Revision: Revision Number: 0.207 Revision Date: 01-14-2022
© 2022 Belden, Inc
All Rights Reserved.
Although Belden makes every reasonable effort to ensure their accuracy at the time of this publication, information and specifications described here in are subject to error or omission and to change without
notice, and the listing of such information and specifications does not ensure product availability.
Belden provides the information and specifications herein on an "ASIS" basis, with no representations or warranties, whether express, statutory or implied. In no event will Belden be liable for any damages
(including consequential, indirect, incidental, special, punitive, or exemplary damages) whatsoever, even if Belden has been advised of the possibility of such damages, whether in an action under contract,
negligence or any other theory, arising out of or in connection with the use, or inability to use, the information or specifications described herein.
All sales of Belden products are subject to Belden's standard terms and conditions of sale.
Belden believes this product to be in compliance with all applicable environmental programs as listed in the data sheet. The information provided is correct to the best of Belden's knowledge, information and belief
at the date of its publication. This information is designed only as a general guide for the safe handling, storage, and any other operation of the product itself or the one that it becomes a part of. The Product
Disclosure is not to be considered a warranty or quality specification. Regulatory information is for guidance purposes only. Product users are responsible for determining the applicability of legislation and
regulations based on their individual usage of the product.