EPC Circuit Breakers and
Enclosures with Interlocked
Arktite
®
Receptacles
APJ/NPJ† and DP Arktite Plugs
Cl. I, Div. 1 and 2, Groups C, D
Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EFC 3, 7CD, 9FG, 12
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Applications:
The EPC interlock receptacle is
designed for use as a service outlet for
portable equipment
It is designed for use in damp, wet and
corrosive locations, indoors or outdoors,
in areas which are hazardous due to
flammable vapors, gases or combustible
dust. For example: refineries, chemical
plants, and other processing and
handling facilities of a hazardous nature
Features:
Mechanical interlock mechanism for
dead front construction
Receptacles are mechanically
interlocked with circuit breakers to
provide disconnect means, short circuit
protection and thermal time delay
overload protection
A spring door receptacle, located at
bottom of 30, 60 and 100 ampere units
and at front of 200 ampere units, is
mechanically interlocked with the circuit
breaker operating mechanism for
maximum safety
Plug and receptacle contacts cannot be
made or broken under load. The circuit
breaker cannot be closed until the plug
is fully inserted and the plug cannot be
withdrawn unless the breaker is open
Operating handles can be padlocked in
either "ON" or "OFF" positions. Breakers
are trip-free of the handles and will open
under short circuit or overload even if
the handle is locked in the "ON" position
Quick installation and leveling is
provided by the three-point mounting
arrangement which has one keyhole slot
at top and two open slots at bottom
Bodies have four taper-tapped conduit
hubs with integral bushings. Two are
located at top and two directly below.
Sizes are as shown in the listings.
Grounding:
EPC interlocked receptacles and
matching plugs are provided with an
extra grounding pole for attaching a
grounding wire. In addition, direct
connection is provided between plug
and receptacle and the grounding pole.
If a separate grounding wire is not
installed in the enclosure, grounding is
accomplished through the conduit
system.
Standard Materials:
Bodies, covers and receptacle housings
– copper-free aluminum
Operating handles – copper-free
aluminum
Operating shafts – stainless steel
Interior parts – sheet steel
Insulation (receptacles and plugs) –
fiberglass-reinforced polyester
Pressure contacts – brass
Crimp/solder contacts – leaded red
brass
Standard Finishes:
Copper-free aluminum – natural
Stainless steel – natural
Sheet steel – electrogalvanized with
chromate finish
Brass – natural
Fiberglass-reinforced polyester – natural
(red)
Leaded red brass – electro-tin-plate
Electrical Rating Ranges:
Receptacle ratings: 30, 60, 100 and 200
amperes
Circuit breakers: 100 and 225 ampere
frame sizes
Certifications and
Compliances:
NEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Groups F, G
Class III
NEMA: 3, 7CD, 9FG, 12
ANSI/UL Standard: 1010
CEC:
Class I, Division 1 and 2, Groups C, D
Class II, Division 1 and 2, Group G
Class III
Encl. 3, 4
30, 60 and 100 ampere size EPC
200 ampere size EPC
Options:
The following special options are available by adding suffix to Cat. #:
Description Suffix
Special polarity – used where two or more receptacles of the same ampere rating,
style and number of poles are to be installed in the same area for use on different
voltages. Available on 30, 60 and 100 ampere units as follows:
Receptacle interior rotated 22
1
/2° clockwise when viewed from face of receptacle
and plug changed to match...........................................................................................
S4
Side bosses drilled and tapped same size as standard hubs, 30, 60 and
100 ampere units only ...................................................................................................
S366
Back boss drilled and tapped same size as standard hubs, 30, 60 and
100 ampere units only ...................................................................................................
S367
Breather and drain (Class I, Class II) .............................................................................
S198V
Breather and drain (Class I only)....................................................................................
S454V
CAUTION: To reduce the risk of ignition of hazardous atmospheres, do not use plugs or receptacles in Class II, Group F
locations that contain electrically conductive dusts.
†Pressure connectors are standard. Crimp/solder type terminators are optionally available for 2, 3 and 4-pole 30 ampere,
3 and 4-pole 60 and 100 ampere. For details, see page 1316. To specify, add the suffix "T" to the catalog number.
For example: APJ3365-T (Plug).
4P
4P
1397
www.crouse-hinds.com US: 1-866-764-5454 CAN: 1-800-265-0502 Copyright
©
2013 Eaton’s Crouse-Hinds Business
4P
EPC Circuit Breakers and
Enclosures with Interlocked
Arktite
®
Receptacles
Cl. I, Div. 1 and 2, Groups C, D
Cl. II, Div. 1 and 2, Groups F, G
Cl. III
NEMA/EFC 3, 7CD, 9FG, 12
Explosionproof
Dust-Ignitionproof
Raintight
Wet Locations
Interchangeability of Plugs with Other
Hazardous and Non-hazardous Location
Receptacles:
Plugs listed for use with 30, 60 and 100 ampere EPC assemblies
are standard Arktite APJ/NPJ plugs. Other standard APJ and CPH
plugs of the same rating, style and number of poles may be used
with EPC receptacles, as well as with DBR, EBBR and EPCB
receptacles listed elsewhere in this section.
As a result, portable equipment suitable for the location and
equipped with the proper plug can be used with AR/NR series
receptacles for non-hazardous locations: EBBR, EPC and EPCB
receptacles for Class I hazardous locations; DR and DBR
receptacles for Class II hazardous locations.
Ordering Information:
100 Ampere Frame Size Thermal-magnetic Circuit Breaker with Non-interchangeable Thermal Trip and
Non-adjustable Magnetic Trip
Circuit Breaker Enclosure
With Circuit Breaker
Receptacle
with Spring
Door Housing Rating
Hub
Size
(In.)
Ckt.
Bkr.
Amps
Without
Circuit
Breaker
Cat. #
Cutler-Hammer
"EHD" Cat. #
General Electric
"TED" Cat. #
30 amp.
2-wire,
3-pole,
Style 2
2-pole,
480VAC‡
or
250 VDC
600VAC† 1
1
/4
20
EPC43032
EPC43032 WT20 2 EPC43032 TT20 2
30 EPC43032 WT30 2 EPC43032 TT30 2
40* EPC43032 WT40 2 EPC43032 TT40 2
50* EPC43032 WT50 2 EPC43032 TT50 2
30 amp.
3-wire,
4-pole,
Style 2
3-pole,
480VAC‡
or
250 VDC
600VAC† 1
1
/4
20
EPC43042
EPC43042 WT20 3 EPC43042 TT20 3
30 EPC43042 WT30 3 EPC43042 TT30 3
40* EPC43042 WT40 3 EPC43042 TT40 3
50* EPC43042 WT50 3 EPC43042 TT50 3
60 amp.
2-wire,
3 pole,
Style 2
2-pole,
480VAC‡
or
250 VDC
600VAC†
1
1
/4
50
EPC46032
EPC46032 WT50 2 EPC46032 TT50 2
60 EPC66032 WT60 2 EPC66032 TT60 2
70* EPC66032 WT70 2 EPC66032 TT70 2
2
90*
EPC66032
EPC66032 WT90 2 EPC66032 TT90 2
100* EPC66032 WT100 2 EPC66032 TT100 2
60 amp.
3-wire,
4-pole,
Style 2
3-pole,
480VAC‡
or
250 VDC
600VAC†
1
1
/4
50
EPC46042
EPC46042 WT50 3 EPC46042 TT50 3
60 EPC66042 WT60 3 EPC66042 TT60 3
70* EPC66042 WT70 3 EPC66042 TT70 3
2
90*
EPC66042
EPC66042 WT90 3 EPC66042 TT90 3
100* EPC66042 WT100 3 EPC66042 TT100 3
100 amp.
2-wire,
3-pole,
Style 2
2-pole,
480VAC‡
or
250 VDC
600VAC† 2
60
EPC61032
EPC61032 WT60 2 EPC61032 TT60 2
70 EPC61032 WT70 2 EPC61032 TT70 2
90 EPC61032 WT90 2 EPC61032 TT90 2
100 EPC61032 WT100 2 EPC61032 TT100 2
100 amp.
3-wire,
4-pole,
Style 2
3-pole,
480VAC‡
or
250VDC
600VAC† 2
60
EPC61042
EPC61042 WT60 3 EPC61042 TT60 3
70 EPC61042 WT70 3 EPC61042 TT70 3
90 EPC61042 WT90 3 EPC61042 TT90 3
100 EPC61042 WT100 3 EPC61042 TT100 3
225 Ampere Frame Size Circuit Breaker with Interchangeable Thermal Magnetic Trip††
Circuit Breaker Enclosure
With Circuit Breaker
Receptacle
with Spring
Door Housing Rating
Hub
Size
(In.)
Ckt.
Bkr.
Amps
Without Circuit
Breaker Cat. #
Cutler-Hammer
"KB" Cat. #
General Electric
"TFK" Cat. #
200 amp.
3-wire,
4-pole,
Style 2
3-pole,
600VAC
or
250 VDC
125
EPC604 2042
EPC604 2042 WT125 3 EPC605 2042 TT125 3
3 150 EPC604 2042 WT150 3 EPC605 2042 TT150 3
175 EPC604 2042 WT175 3 EPC605 2042 TT175 3
3 200
EPC605 2042
EPC604 2042 WT200 3 EPC605 2042 TT200 3
225* EPC604 2042 WT225 3 EPC605 2042 TT225 3
*Circuit breaker trip rating may exceed receptacle rating for welding equipment applications only,
as higher trip rating may not protect wiring.
††200 ampere units are suitable for Class I, Group D (NEMA 7D).
‡Enclosures with 600 volt circuit breakers from U.S.A. are available. Information on request.
†CSA Certified units are supplied with 600VAC FDB frame circuit breakers.
CAUTION: To reduce the risk of ignition of hazardous
atmospheres, do not use plugs or receptacles in Class II, Group
F locations that contain electrically conductive dusts.