HOLLYLAND (CHINA) ELECTRONICS
TECHNOLOGY CORPORATION LTD.
PRODUCT
SPECIFICATION
ISSUED DATE
REV. NO.
DOC. NO.
PAGE
2015/4/15
A00
HLD-PSI-1072
Page 1 of 5
H3FD SERIES
PREPARED BY
2015-4-15
CHECKED BY
2015-4-15
APPROVED BY
2015-4-15
1. 适用范围/ SCOPE
本规格书适用于本公司生产的 H3FD series HOLLY
商标的螺栓连接熔断体。本产品适用于 690V AC 及以下电压
半导体器件的保护。
This specification defines the technical requirements of fuse-links
with bolted connections type H3FD series with
HOLLY
brand. The fuse series designed for semiconductor devices where voltage 690V or below.
产品部件号 PART NUMBER
目录编号 Part No.
额定电流
Rated
Current
额定电压
Rated
Voltage
分断电流
Breaking
Current
功耗
Watts Loss
W
H3FD500
H3FD550
H3FD630
H3FD700
H3FD800
H3FD900
H3FD1000
H3FD1100
H3FD1250
H3FD1400
H3FD1500
H3FD1600
500A
550A
630A
700A
800A
900A
1000A
1100A
1250A
1400A
1500A
1600A
690V AC
200kA
96
100
106
110
116
120
125
130
140
155
160
165
170
180
H3FD1800 1800A
600V AC
H3FD2000 2000A 550V AC
2.相关标准及认证情况 APPLICABLE STANDARDS & APPROVED DETAILS
2.1 H3FD 系列产品适用的相关标准是 IEC 60269-4GB/T 13539.4,
Applicable standards for H3FD series are IEC 60269-4 and GB/T 13539.4.
3. 构造图 CONSTRUCTION FIG. & DIMENSION
1600A:53
1600A:65
73.5
M
12
73.5
86
φ30
HOLLYLAND (CHINA) ELECTRONICS
TECHNOLOGY CORPORATION LTD.
PRODUCT
SPECIFICATION
ISSUED DATE
REV. NO.
DOC. NO.
PAGE
2015/4/15
A00
HLD-PSI-1072
Page 2 of 5
H3FD SERIES
3.1 原材料规格 MATERIAL
编号 NO.
品名 PART 材料 MATERIAL 备注 REMARK
1
陶瓷管 Ceramic Tube 陶瓷 Ceramic
2
触刀 Contact Copper
3
盖板 Board 黄铜 Brass
4
指示器 Indicator 陶瓷 Ceramic
5
铜帽 Cap 黄铜 Brass
6
垫片
Washer 石墨 Graphite
7
可熔体 Fusible Element 金属片 Metal Sheet
8
石英砂 Quartz Sand 二氧化硅 Silicon Dioxide
9
螺钉 Bolt Steel
10
指示器拉线 Indicator line 金属丝 Wire
11
微动开关底座
Microswitch base
热固性塑料
Thermosetting Plastics
3.2 陶瓷管 Ceramic Tube
陶瓷管无破裂、缺损或污染等现象。
Ceramic tube shall have no defects such as crack, injury and contamination.
4.电气特性 ELECTRICAL PERFORMANCES
4.1 测试条件 TEST CONDITIONS
全部测试条件都应在环境温度 20±5℃条件下进行。
All electrical tests are conducted at a ambient temperature of 20±5.
4.2 负载能力测试 CURRENT-CARRYING CAPACITY TEST
当熔断体通以100%倍额定电流的条件下进行测试时,在4小时内电路不应断开,熔断体不被电流熔断,管体不破裂。
A fuse-link shall carry 100% of rated current for 4 hours, and the circuit shall not be opened. While the fuse is
carrying this current, no open circuit, melt fusible element, and ruptured tube shall occur in any manner during this
test.