1. 适用范围/ SCOPE
本规格书适用于本公司生产
并获得
cULus
认证的
HC10SR RoHS 系列 HOLLY
商标的圆筒型帽熔断体。
This specification defines the technical requirements of fuse-links having cylindrical contact caps type HC10SR
RoHS series with HOLLY
brand which have been approved by cULus.
产品部件号为: 型号
额定电流 额定电压
Construction of part no:
type rated current rated voltage
例如 For Example: 10SR 10 U6
* 额定电压 Rated voltage: U6 - 600V~
产品部件号 PART NUMBER
目录编号
Part No.
额定电流
Rated Current
额定电压
Rated Voltage
目录编号
Part No.
额定电流
Rated Current
额定电压
Rated Voltage
10SR1U6
10SR1.25U6
10SR1.5U6
10SR1.6U6
10SR2U6
10SR2.5U6
10SR3U6
10SR3.15U6
10SR3.5U6
10SR4U6
10SR5U6
10SR6U6
1A
1.25A
1.5A
1.6A
2A
2.5A
3A
3.15A
3.5A
4A
5A
6A
600V AC
10SR6.3U6
10SR7U6
10SR7.5U6
10SR8U6
6.3A
7A
7.5A
8A
600V AC
10SR9U6
10SR10U6
10SR12U6
10SR15U6
10SR16U6
10SR20U6
10SR25U6
10SR30U6
9A
10A
12A
15A
16A
20A
25A
30A
600V AC
300V DC
2.相关标准 APPLICABLE STANDARDS
2.1 HC10SR RoHS 系列产品适用的相关标准是 UL248-1UL248-4CSA C22.2 NO.248.1-00CSA C22.2
NO.248.4-00
Applicable standards for HC10SR RoHS series are are UL248-1UL248-4CSA C22.2 NO.248.1-00CSA
C22.2 NO.248.4-00
2.2
认证情况
APPROVED DETAILS
额定电压
Rated Voltage
cULus
备注
Remark
认证范围
Approved Range
认证号码
Cert. No.
600V AC 1A~30A E346810 /
300V DC 9A~30A E346810 /
3.公司地址 ADDRESS
中国福建省厦门市湖里区枋湖路 9-19
NO. 9-19, FANGHU ROAD, HULI, XIAMEN, FUJIAN, CHINA.
HOLLYLAND CHINAELECTRONICS
TECHNOLOGY CORPORATION LIMITED
PRODUCT
SPECIFICATION
ISSUED DATE
REV. NO.
DOC. NO.
PAGE
2013/4/22
A02
HLD-PSI-1004
Page 2 of 5
HC10SR RoHS SERIES
4. 构造图 CONSTRUCTION FIG. & DIMENSION
4.1 原材料规格 MATERIAL
编号 NO.
品名 PART 材料 MATERIAL 备注 REMARK
16
铜帽 Cap 黄铜 Brass
2 内帽 Inner Cap 黄铜 Brass
3 陶瓷管 Ceramic Tube 陶瓷 Ceramic
4 可熔体 Fusible Element
玻璃纤维线+金属丝
Glass Fiber+ Metal Wire
金属片& Metal Sheet
5 石英砂 Quartz Sand 二氧化硅 Silicon Dioxide
4.2 陶瓷管 Ceramic Tube
陶瓷管无破裂、缺损或污染等现象。
Ceramic tube shall have no defects such as crack, injury and contamination.
5.电气特性 ELECTRICAL PERFORMANCES
5.1 测试条件 TEST CONDITIONS
全部测试条件都应在环境温度 25±5℃条件下进行。
All electrical tests are conducted at a ambient temperature of 25±5.
5.2 负载能力测试 CURRENT-CARRYING CAPACITY TEST
当保险丝通以100%倍额定电流的条件下进行测试时,4小时内电路不应断开,保险丝不被电流熔断,管体不破
裂。
A fuse-link shall carry 100% of rated current for 4 hours, and the circuit shall not be opened. While the fuse is
carrying this current, no open circuit, melt fusible element, and ruptured tube shall occur in any manner during this
test.
5.3 温度上升试验TEMPERATURE RISE TEST
当保险丝通以 100%倍额定电流的条件下进行测试时,在达到热量平衡后,测量保险丝表面的温度,保险丝表
面的温度上升必须等于或低于 75℃。注:温度上升=保险丝表面的温度-环境温度。
Measure the temperature of the surface of the fuse under the 100% rated current, when the thermal equilibrium
reaches. The temperature rise on the surface of each fuse shall be 75 or less.
Note: Temp. rise = fuse temp. room temp.
5.4 时间-电流特性TIME-CURRENT CHARACTERISTICS
当保险丝通���下表规定的电流时,其熔断时间必须符合下表的要求,且铜帽不能飞脱、管体不应破裂、损坏。
When the current in the following table is passing the fuse, its opening time must be in accordance with the
requirements in the following table, that is, the pre-arcing time. Moreover, neither damage of the fuse-tube nor
shattering of the cap shall occur.
6
38.10± 0.79
φ10.29± 0.13
φ6.35± 0.13
123
4