C6RL11
2019.12.19
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com
RoHS
ü
FEATURES
AGENCY RECOGNITION
Made for RFE by UL shop Fuzetec
• UL (E211981)
• C-UL (E211981)
• TÜV (R50087018)
Applications : Line Voltage Power Supply, Transformer and Appliance
• Product Features : Low hold current, Solid State, Ideal for up to 240V ac/dc
• Operation Current : 0.05A ~ 2.00A
• Maximum Operating Voltage : 240V ac/dc
• Maximum Interrupt Voltage : 265V ac/dc
• Temperature Range : FRV005 ~ FRV055 ... -40°C to 85°C
FRV075 ~ FRV200 ... -20°C to 85°C
THERMAL DERATING CURVE
ELECTRICAL CHARACTERISTICS (23°C)
NOTE: All Specifications subject to change without notice.
Page 1 of 2
IH=Hold current-maximum current at which the device will not trip at 23°C still air.
IT=Trip current-maximum current at which the device will always trip at 23°C still air.
V MAX=Maximum voltage device can withstand without damage at its rated current.
I MAX=Maximum fault current device can withstand without damage at rated voltage (V MAX).
Pd=Typical power dissipated from device when in the tripped state in 23°C still air environment.
R MIN=Minimum device resistance at 23°C.
R1MAX=Maximum device resistance at 23°C, 1 hour after tripping.
Physical specifications:
Lead material: FRV005 ~ FRV016 Tin plated copper, 24 AWG.
FRV025 ~ FRV040 Tin plated copper, 22AWG
FRV055 ~ FRV200 Tin plated copper, 20AWG
Soldering characteristics: MIL-STD-202, Method 208E.
Insulating coating: Flame retardant epoxy, meet UL-94V-0 requirement.
RADIAL LEADED PPTC RESETTABLE FUSE
FRV Series: 0.05A ~ 2A Up to 240V AC/DC
0%
50%
100%
150%
200%
-40 -20 0 20 40 60 80
Precent of Rated Hold and Trip Current
Ambient Temperature (C)
FRV Series
A
= FRV005-240F~
FRV055-240F
B
= FRV075-240F
~
FRV200-240F
R min R1 max
IH, A IT, A at 5 x IH, S IMAX, A VMAX, Vac/dc VI-MAX, Vac/dc Pd, W Ohms Ohms
FRV005-240F 0.05 0.12 15.0 1.0 240 265 0.7 18.50 65.00
FRV008-240F 0.08 0.19 15.0 1.2 240 265 0.8 7.40 26.00
FRV012-240F 0.12 0.30 15.0 1.2 240 265 1.0 3.00 12.00
FRV016-240F 0.16 0.37 15.0 2.0 240 265 1.4 2.50 7.80
FRV025-240F 0.25 0.56 18.5 3.5 240 265 1.5 1.30 3.80
FRV033-240F 0.33 0.74 21.0 4.5 240 265 1.7 0.83 2.60
FRV040-240F 0.40 0.90 24.0 5.5 240 265 2.0 0.60 1.90
FRV055-240F 0.55 1.25 26.0 7.0 240 265 3.4 0.45 1.45
FRV075-240F 0.75 1.50 18.0 7.5 240 265 2.6 0.32 0.84
FRV100-240F 1.00 2.00 21.0 10.0 240 265 2.9 0.22 0.58
FRV125-240F 1.25 2.50 23.0 12.5 240 265 3.3 0.17 0.44
FRV150-240F 1.50 3.00 23.0 15.0 240 265 3.7 0.12 0.32
FRV200-240F 2.00 4.00 28.0 20.0 240 265 4.5 0.09 0.22
Max. Int.
Voltage
Typical
Power
Resistance
Part Number
Hold
Current
Trip
Current
Max. Time
to Trip
Maximum
Current
Max. Oper.
Voltage
RFE International • Tel:(949) 833-1988 • Fax:(949) 833-1788 • E-Mail Sales@rfeinc.com
Page 2 of 2
DIMENSIONS (mm)
TYPICAL TIME-TO-TRIP AT 23°C
NOTE: All Specifications subject to change without notice.
RoHS
ü
C6RL11
2019.12.19
Fig.1
Fig.2
Fig.3
Fig.4
Lead Size: 24AWG
Lead Size: 22AWG
Lead Size: 20AWG
Lead Size: 20AWG
Φ 0.51
mm Diameter
Φ 0.65
mm Diameter
Φ 0.81
mm Diameter
Φ 0.81
mm Diameter
A B C D E F
Maximum Maximum Typical Minimum Maximum Typical
FRV005-240F
1 8.3 10.7 5.1 7.6 3.8 1.6
FRV008-240F
1 8.3 10.7 5.1 7.6 3.8 1.6
FRV012-240F
1 8.3 10.7 5.1 7.6 3.8 1.6
FRV016-240F
1 9.9 12.5 5.1 7.6 3.8 1.6
FRV025-240F
2 9.6 17.4 5.1 7.6 3.8 1.8
FRV033-240F
2 11.4 16.5 5.1 7.6 3.8 1.8
FRV040-240F
2 11.5 19.5 5.1 7.6 3.8 1.8
FRV055-240F
3 14.0 21.7 5.1 7.6 4.1 1.9
FRV075-240F
3 11.5 23.4 5.1 7.6 4.8 1.9
FRV100-240F
4 18.7 24.4 10.2 7.6 5.1 1.9
FRV125-240F
4 21.2 27.4 10.2 7.6 5.3 1.9
FRV150-240F 4
23.4 30.9 10.2 7.6 5.3 1.9
FRV200-240F 3
24.9 33.8 10.2 7.6 6.1 1.9
Part Number Fig.
0.01
0.1
1
10
100
1000
0.1 1 10 100
Time-to-trip (S)
Fault current (A)
A B C D E FG HI
J KL
M
FRV Series
A= FRV005-240F
B= FRV008-240F
C= FRV012-240F
D= FRV016-240F
E= FRV025-240F
F= FRV033-240F
G= FRV040-240F
H= FRV055-240F
I= FRV075-240F
J= FRV100-240F
K= FRV125-240F
L=FRV150-240F
M= FRV200-240F
RADIAL LEADED PPTC RESETTABLE FUSE
FRV Series: 0.05A ~ 2A Up to 240V AC/DC