Specification
Requirement
Description
Power supply space
Rated input voltage
100 to 240VAC, 50 to 60Hz
Permissible input voltage *
85 to 264VAC, 50 to 60Hz
Input current
0.55A typ (100VAC), 0.35A typ (230VAC)
Rated output voltage
24VDC
Rated output current
1.3A (Max.)
Isolation
Input-Output
3000VAC 1minute 50MΩ (500VDC)
(At room temperature)
Input-PE
2000VAC 1minute 50MΩ (500VDC)
(At room temperature)
Output-PE
500VAC 1minute 50MΩ (500VDC)
(At room temperature)
Environmental specs
Temperature *
Operating : -20 to +70°C,
non operating : - 30 to + 85°C
Humidity
Operating : 20 to 90%RH (No condensation)
Non operating : 20 to 90%RH (No condensation)
Floating dust particles
Not to be excessive
Corrosive gases
None
Vibration resistance
10 to 55Hz / 2.0G
Construction
Length of DC cable (mm)
200 (not include connector)
External dimensions (mm)
22.5(W)x75(D)x90(H) (not include projection)
Weight
Main body : 165g Max.
Longevity
7years
(temperature 50ï‚° C,Input 100VAC, Output 0.9A)
Standard
FCC Class B, UL/c-UL, TUV
CE Marking (EMC Directive Class B, LVD, RoHS Directive)
* T he derating is required.
Packing List
Power Supply …1
Product gu ide … 1
Serial Number Label …1
DC Ca bl e …1
Warr anty Certificate …1
* This product requires an AC cable. We also have recommended AC cable ready to be purchased.
For more details, please refer to the Contec website. http://www.contec.co.jp
List of Optional
AC power cable
IPC-ACCODE3 : AC cable with 3-round-end terminal
(Length : 2 meters, Rating : 7A 125V)
* Visit the Contec website regarding information on the optional products
6.6
9.3
8.3
10.9
6.6
9.3
60.1
47.5
20
7.45
22.5
11.25
5-M3.5
94.510max
75
90
84
(40.5)
230
200
6.6(Max.)
3.7(Min)
Ver.1.03
CPS-PWD-30AW24-01 2
External Dimensions
Derating by input voltage
Figure below shows derating curve by input voltage.
Input voltage derating curve
Derating by operating ambient temperature.
The operative ambient temperature as different by input voltage.
Derating curve is shown below.
In the hatched area, the specification of Ripple, Ripple Noise is different
from other area.
Derating Curve (Convection)
Derating curve depend on ambient temperature