Test Report No. 3494776-CH01-R2 Date: July 2, 2014 Page 1 of 4
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or
accessible at http://www.sgs.com/en/Terms-and-Conditions.a spx and, for electronic format documents, subject to Terms and
Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to
the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information
contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising
all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior
written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 45 days only.”
SGS North America Inc. 291 Fairfield Ave., Fairfield, NJ 07004, USA t (973) 575-5252 f (973) 575-7175 www.us.sgs.com/cts
Member of the SGS Group (SGS SA)
Transko Electronics, Inc.
3981 E. Miraloma Ave.
Anaheim, CA 92806
United States
This report su persedes all previous documents bearing the test report number 3494776-CH01-R1.
The following sample(s) was/were submitted
and identified by/on behalf of the client as:
Ceramic SMD crystal
Model/Part No.: CS series
Sample Received Date:
5/15
/2014
Testing Period:
5/17/2014
Test Requested : Please refer to the result summary.
Test Method & Results : Please refer to next page(s).
Result Summary :
Test Requested Comment
European Directive 2011/65/EU Annex II
(RoHS); recasting 2002/95/EC
PASS
Signed for and on behalf of SGS North America, Inc. Prepared By:
Christina Crimi
Laboratory Manager, Chemistry Laboratory
Veronica Marrero
Laboratory Operations Lead, Chemistry
Laboratory
Test Report No. 3494776-CH01-R2 Date: July 2, 2014 Page 2 of 4
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or
accessible at http://www.sgs.com/en/Terms-and-Conditions.a spx and, for electronic format documents, subject to Terms and
Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn to
the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information
contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s instructions, if
any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising
all their rights and obligations under the transaction documents. This document cannot be reproduced except in full, without prior
written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or appearance of this document is
unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 45 days only.”
SGS North America Inc. 291 Fairfield Ave., Fairfield, NJ 07004, USA t (973) 575-5252 f (973) 575-7175 www.us.sgs.com/cts
Member of the SGS Group (SGS SA)
1. European Directive 2011/65/EU Annex II (RoHS); recasting 2002/95/EC:
Cadmium, Lead, Mercury, Hexavalent Chromium, Polybromobiphenyl (PBB) and Polybromodiphenyl ether
(PBDE) content
Method : With reference to IEC 62321-5:2013. Lead, Cadmium and M ercury were analyzed by Inductively
Coupled Argon Plasma Spectrometry, Chromium (VI) was analyzed by UV-Visible Spectroscopy
and PBB, PBDE were analyzed by Gas Chromatography Mass Spectrometry (GC-MS).
Test Item
Result (mg/kg)
Detection Limit
(mg/kg)
Permissible Limit
(mg/kg)
1
Cadmium (Cd) ND 2 100
Lead (Pb) 7 2 1000
Mercury (Hg) ND 2 1000
Hexavalent Chromium
(Cr(VI))
ND 2 1000
Sum of PBBs ND -- 1000
Monobromobiphenyl ND 5 --
Dibromobiphenyl ND 5 --
Tribromobiphenyl ND 5 --
Tetrabromobiphenyl ND 5 --
Pentabromobiphenyl ND 5 --
Hexabromobiphenyl ND 5 --
Heptabromobiphenyl ND 5 --
Octabromobiphenyl ND 5 --
Nonabromobiphenyl ND 5 --
Decabromobiphenyl ND 5 --
Sum of PBDEs
ND -- 1000
Monobromodiphenyl ether ND 5 --
Dibromodiphenyl ether ND 5 --
Tribromodiphenyl ether ND 5 --
Tetrabromodiphenyl ether ND 5 --
Pentabromodiphenyl ether ND 5 --
Hexabromodiphenyl ether ND 5 --
Heptabromodiphenyl ether ND 5 --
Octabromodiphenyl ether ND 5 --
Nonabromodiphenyl ether ND 5 --
Decabromodiphenyl ether ND 5 --
Comment
PASS -- --
Sample Description:
1. CS Series