V11
1
TR36M SERIES
36W MEDICAL
SWITCHING ADAPTER
Features
* Universal Input Range 80~264VAC
* Approved EN55011, FCC CFR47 Part15 Class B
* Meets EN60335
* Approved EN60601-1-11
for Home Healthcare Applications
* Low Leakage Current < 80uA
* Continuous Short Circuit Protection
* Over Voltage Protection
* Meet CoC Tier 2 & DoE Level VI
(Output Cable Length
1800mm)
(TR36M050: Output Cable Length
1220mm)
* No Load Power Consumption < 75mW
* 2 MOPP Class II
Ordering information
TR36M
XXX
-XX X XX
Model No. DC Plug Type G: UL1571 WITH OVP
DC Cable Length and Type
E: UL1185 WITH OVP
01: 720mm
02: 1220mm
03: 1800mm
11: 720mm with Ferrite Core
12: 1220mm with Ferrite Core
13: 1800mm with Ferrite Core
* 16AWG /
UL1571 or Equivalent
for Vo: 5V
* 18AWG /
UL1571 or Equivalent
for Vo: 9V, 12V, 13.5V
* 20AWG /
UL1571 or Equivalent
for Vo: 15V, 18V, 24V
* 20AWG /
UL1185 or Equivalent
for Vo: 36V, 48V
章 節
TR-54
頁 次
1-1
Specifications are subject to change without notice.
MODEL
OUTPUT
VOLTAGE
OUTPUT
CURRENT
RIPPLE &
NOISE
NOTE 1
VOLTAGE
ACCURACY
NOTE 2
LINE
REGULATION
NOTE 3
LOAD
REGULATION
NOET 4
% EFF. (Typ.)
NOTE 5
TR36M050 5V 5.0A 100mVp-p ±2% ±1% ±6% 85%
TR36M090 9V 3.3A 120mVp-p ±2% ±1% ±4% 88%
TR36M120 12V 2.5A 120mVp-p ±2% ±1% ±2% 89%
TR36M135 13.5V 2.4A 130mVp-p ±2% ±1% ±2% 89%
TR36M150 15V 2.4A 150mVp-p ±2% ±1% ±2% 89%
TR36M180 18V 2.0A 180mVp-p ±2% ±1% ±2% 89%
TR36M240 24V 1.5A 240mVp-p ±2% ±1% ±2% 89%
TR36M360 36V 1.0A 360mVp-p ±2% ±1% ±2% 89%
TR36M480 48V 0.75A 480mVp-p ±2% ±1% ±2% 89%
V11
2
Specifications
TR36M Series Derating Curve
INPUT SPECIFICATIONS:
Voltage …....………........…............................... 80~264Vac(80Vac derating)
Frequency …………………………………………………………..... 47 to 63Hz
Input Current ………………….……………..................................... 0.9A max.
Inrush Current ………….… Cold start@25
……….. 100A max. @240Vac
Leakage Current …………..………………………………….…… 80uA max.
OUTPUT SPECIFICATIONS:
Hold-up Time ………….……………………………… 10ms typ. @115Vac
Short Circuit Protection ……….. Hiccup Mode Continuous(Auto Recovery)
Over Voltage Protection ………..
IC Component to Clamp(Auto Recovery)
Temperature Coefficient …………………….................................. ±0.05%/
GENERAL SPECIFICATIONS:
Isolation …………………………………………… Input to output 4,000VAC
Operating Temperature ................................ -20 ~ 60
(see derating curve)
Storage Temperature ……..……………………...….......……........ -20~85
Humidity …………………...…….......…......... 93% RH max. Non condensing
Cooling ……………………………………….…………….. Natural Convection
Switching Frequency …………………………………………… 65KHz Typical
MTBF ..….. MIL-HDBK-217F, GB, 25
/115VAC …….…..… 1000Khrs max.
Altitude ……………………………………………………………..…… 5000m
Dimensions ……….. 3.937x1.771x0.886 inches (100.00x45.00x22.50mm)
Weight ……………………………………….………….……150g(0.33 Pounds)
NOTE:
SAFETY AND EMC:
1. Add a 0.1uF ceramic capacitor and a 10uF E.L. capacitor to output for
Emission and Immunity (Ed4.0) …………………… EN55011, EN60601-1-2
ripple & noise measuring @20MHz BW.
EN61000-3-2, EN61000-3-3, IEC61000-4-2, 3, 4, 5, 6, 8, 11
2. Voltage setpoint at 60% full load.
FCC CFR47 Part 15 Class B
3. Line regulation is measured from 100Vac to 240Vac full load.
Safety Approved (Ed.3.1) ……….… IEC60601-1:2005+A1, EN60601-1-11
4. Load regulation is measured from 60% to full load and from 60% to
EN60601-1:2006+A11:2011+A1+A12
20% load (60% +/- 40% load).
ANSI/AAMI ES60601-1:2005/A1:2012
5. Efficiency measured at 75% load and input voltage is 230Vac.
Mechanical Specification
Tolerance:Inches:X.XXX±0.02
Millimeters:X.XX±0.5
All Dimensions are in inches[mm]
3.937[100.00]
1.771[45.00]0.886[22.50]
DC Plug :Right Angle(ψ5.5/ψ2.1)L12mm
DC Plug type: V+ ─●)─ V-
20AWG/1800mm
70.866[1800.00]±1.969[50.00]
IEC320/C8
Typical at 25˚C, nominal line and 75% load, unless otherwise Specified
0%
20%
40%
60%
80%
100%
-20 -10 0 10 20 30 40 50 60
Ambient Temperature(
o
C)
Rated Load(%)