Data Acquisition System GM
First Step Guide
IM 04L55B01-02EN
7th Edition
Contents
Introduction ................................................................................. 2
Checking the Package Contents ................................................. 3
MODEL and SUFFIX Codes ....................................................... 4
Standard Accessories ................................................................. 5
Module Notation .......................................................................... 6
GM Overview ............................................................................. 6
GM Conguration ........................................................................ 6
Module Version and Notes on Linking .......................................... 6
Channel Names .......................................................................... 7
Operating Procedure ........................................................8
Basic Operation .............................................................. 10
Names of the GM10 Parts ..........................................................10
Conguring the GM via Ethernet Communication .......................10
Conguring the GM via USB Communication .............................12
Starting to Measure and Record .................................................12
Installation.......................................................................13
Installation Location ....................................................................13
Installation Procedure .................................................................13
Unit External Dimensions (Unit: mm) ...........................................13
Installing on a Desktop or Floor.................................................. 14
Mounting on a DIN Rail .............................................................. 14
Mounting on a Wall .................................................................... 14
Wiring .............................................................................. 15
Precautions to Be Taken While Wiring ........................................16
Removing and Attaching a Terminal Cover .................................16
Removing and Attaching a Terminal Block ..................................16
Wiring Procedure .......................................................................17
Internal dimensions of the M3 screw terminal (unit: mm) .............17
Wiring the Clamp Terminal ..........................................................17
Wiring to a GX90XA Analog Input Module ..................................17
Wiring to a GX90XD Digital Input Module....................................19
Wiring to a GX90YD Digital Output Module .................................19
Wiring to a GX90WD Digital I/O Module .................................... 20
Wiring to a GX90XP Pulse Input Module.................................... 20
Wiring to a GX90YA Analog Output Module ............................... 20
Wiring to a GX90UT PID Control Module ................................... 20
Connecting to the RS-422/485 Connector
(/C3 option) ............................................................................21
Connecting to the USB Port .......................................................21
Connecting to the Ethernet Port .................................................21
Wiring the Power Supply ........................................................... 22
Turning the Power On and O ................................................... 23
Connecting GX90EX Expansion Modules ................................. 23
Bluetooth Connection Procedure (/C8 option) ............................ 24
Users
Manual
2
IM 04L55B01-02EN
Introduction
Thank you for purchasing the SMARTDAC+ GM Data
Acquisition System (hereafter referred to as the GM). This
manual explains the basic operation, installation, and wiring
of the GM.
For details on configuring and operating the GM, see
the GM Data Acquisition System User’s Manual (IM
04L55B01-01EN) provided in electronic format.
For details on the settings and operation of the PID
control module and program control (/PG option), see
the Loop Control Function, Program Control Function (/
PG Option) User’s Manual (IM 04L51B01-31EN) and the
SMARTDAC+ STANDARD Hardware Configurator User’s
Manual (IM 04L61B01-02EN), provided as electronic
manuals.
This manual covers the following products and I/O modules
(GX90 series).
Model Product name
GM10 Data Acquisition Module for SMARTDAC+ GM
GM90PS Power Supply Module for SMARTDAC+ GM
GM90MB Module Base for SMARTDAC+ GM
This manual denotes devices with their product names or
model (e.g. GM10).
To ensure correct use, please read this manual and the
following manuals thoroughly before beginning operation.
Paper Manuals
Manual Title Manual No.
Data Acquisition System GM
First Step Guide
IM 04L55B01-02EN
(this manual)
Precaution on the use of SMARTDAC+ IM 04L51B01-91EN
(included)
Regarding the Downloading and Installing for the
Software, Manuals and Labels
About the Usage of Open Source Software
IM 04L61B01-11EN
(included)
Electronic Manuals and General Specifications
You can download these documents from the following web
page:
http://www.smartdacplus.com/manual/en/
See page 4 in Precaution on the use of SMARTDAC+ (IM
04L51B01-91EN).
Genaral Specifications
Title General
Specifications No.
Data Acquisition System GM GS 04L55B01-01EN
GX90XA/GX90XD/GX90YD/GX90WD/GX90XP
I/O modules
GS 04L53B01-01EN
GX60 I/O Base Unit (Expandable I/O) / GX90EX
Expansion Module
GS 04L53B00-01EN
User Registration
Thank you for purchasing YOKOGAWA products.
We invite you to register your products in order to receive the most up
to date product information. To register, visit the following URL.
http://www.yokogawa.com/ns/reg/
Notes
The contents of this manual are subject to change without
prior notice as a result of continuing improvements to the
instrument’s performance and functions.
Every effort has been made in the preparation of this
manual to ensure the accuracy of its contents. However,
should you have any questions or find any errors, please
contact your nearest YOKOGAWA dealer.
Copying or reproducing all or any part of the contents of
this manual without YOKOGAWA’s permission is strictly
prohibited.
Revisions
December 2014 1st Edition March 2019 7th Edition
August 2015 2nd Edition
December 2015 3rd Edition
June 2017 4th Edition
July 2018 5th Edition
October 2018 6th Edition
Trademarks
SMARTDAC+ and SMARTDACPLUS are registered
trademarks or trademarks of Yokogawa Electric
Corporation.
Microsoft and Windows are registered trademarks or
trademarks of Microsoft Corporation in the United States
and other countries.
Pentium is a registered trademark of Intel Corporation.
Adobe and Acrobat are registered trademarks or
trademarks of Adobe Systems Incorporated.
The SD logo is a registered trademark of the SD
association.
Bluetooth is a trademark or registered trademark of
Bluetooth SIG, Inc.
Company and product names that appear in this manual
are registered trademarks or trademarks of their respective
holders.
The company and product names used in this manual are
not accompanied by the registered trademark or trademark
symbols (® and ™).
QR code
The product may have a QR Code pasted for efficient plant
maintenance work and asset information management.
It enables confirming the specifications of purchased products
and user’s manuals.For more details, please refer to the
following URL.
https://www.yokogawa.com/qr-code
QR Code is a registered trademark of DENSO WAVE
INCORPORATED.
Safety Precautions
Read this manual and “Precaution on the use of
SMARTDAC+” (IM04L51B01-91EN) thoroughly and have a
clear understanding of the product before operation.
This manual explains the functions of the product. It does
not guarantee that the product will suit a particular purpose
of the user.
Keep “Precaution on the use of SMARTDAC+” and all the
related manuals with SMARTDAC+ GM until the end of the
use of the product.
When SMARTDAC+ GM contains GM10 with the optinal
code of /C8, SMARTDAC+ GM is built in compliance with
requirements of R&TTE Derective:
We, Yokogawa Electric Corporation hereby declare that
this equipment, model GM Data Acquisition system is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC.
The EU declaration of conformity for R&TTE for this
product can be found at < http://www.smartdacplus.com/