159
ipf electronic gmbh
��� Kalver Straße 25 - 27 • 58515 Lüdenscheid • Germany
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
info@ipf-electronic.com • www.ipf-electronic.com
P
at robust design
P
4-pin M12-connector for the connecon cable to the
control unit
P
status displays by LED
P
system of protecon IP67
P
simple vibraon-proof connecon of sensor leads
AND / OR logic operaon on locaon
minimized wiring eort
descripon
It is oen the case that the signals of many sensors are linked
in an applicaon in order to provide a statement about an
operaonal state.
If this linkage is adopted in the control unit, it is necessary to
run the signals of each sensor up unl there via leads, and
process them in the control program.
In many cases, it would be sucient to link the sensor signals
to one another on-site and only transmit one linked end-signal
to the control unit.
ipf electronic logic distribuon terminals are used for this
purpose. According to the module, up to 8 sensors can be
connected and logically linked to one another.
AND and OR versions are available as logical variants. The user
can directly see which signals are pending and/or which are
missing (as the case may be) by means of LED status display
of the logic modules. The status of the linked end signals is
similarly shown via output LEDs.
The 2 x 2-way / 2 x 4-way types have two separated signal
outputs. In these types the input signals of the right and le
module halves are linked independent from each other.
If, in the case of an AND module, an input slot cannot be taken
up by a sensor, a so-called “jumper plug“ can be supplied.
applicaon examples
u signal linkage of mulple sensors
design 60 x 122 x 41.5mm
60 x 172 x 41.5mm
logic distributor 1 x 4-way AND / OR
2 x 2-way AND / OR
1 x 8-way AND / OR
2 x 4-way AND / OR
ACCESSORIES
LOGIC MODULES 1700
14
160
ipf electronic gmbh
• Kalver Straße 25 - 27 • 58515 Lüdenscheid • Germany
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
info@ipf-electronic.com • www.ipf-electronic.com
TECHNICAL DATA
input pnp, (signal on pin 4) pnp, (signal on pin 4)
output see above see above
operang voltage 10 ... 30V DC 10 ... 30V DC
current consumpon (max. load) 1A 1A
output current (max. load) 200mA per output 200mA per output
insulaon resistance > 10
9
Ω > 10
9
Ω
display (funcon) operang voltage: 2 x green LED (both on) operang voltage: 1 x green LED
display (signal) 1 x yellow LED per slot 1 x yellow LED per slot
housing material plasc (PBT) plasc (PBT)
contact meterial CuZn, nickel underplang and gold plated CuZn, nickel underplang and gold plated
plug-in and pull-out power ≥ 0.5N plug-in and pull-out power ≥ 0.5N
design 60x122x41.5mm 60x172x41.5mm
operang temperature -20 ... +70°C -20 ... +70°C
plug-in cycles ≥ 50 ≥ 50
soiling degree 3 3
inammability class UL 94 V-0 UL 94 V-0
system of protecon (EN 60529) IP67 - only when screwed with the IP67 - only when screwed with the
corresponding counterparts or blank plugs corresponding counterparts or blank plugs
connecon module: M12-connector, 4-pin module: M12-connector, 4-pin
connecon accessories cable socket, e.g. VK500325, 5m, PUR, straight cable socket, e.g. VK500325, 5m, PUR, straight
connecon sensors: 4 x M12-socket, 4-pin sensors: 8 x M12-socket, 4-pin
connecon accessories connecon cable, e.g. VK200F25, 2m, PUR, straight connecon cable, e.g. VK200F25, 2m, PUR, straight
arcle-no. VL600104 VL600108
output AND-linked, 4-way AND-linked, 8-way
arcle-no. VL600114 VL600118
output AND-linked, 2 x 2-way AND-linked, 2 x 4-way
arcle-no. VL600124 VL600128
output OR-linked, 4-way OR-linked, 8-way
arcle-no. VL600134 VL600138
output OR-linked, 2 x 2-way OR-linked, 2 x 4-way
ACCESSORIES
1700 LOGIC MODULES