P/L LV AIRGUARD VFD - 09/2017
DESIGN & CONSTRUCTION
CONDUCTOR
Annealed Class B copper conductor
according to ASTM B3 & ASTM B8
from #14 AWG through 750 kcmil
multiconductor
INSULATION
Cross linked polyethylene (XLPE) XHHW-2
GROUND WIRES
Power cable conductors are assembled
with three (3) bare copper ground wires
per UL, ICEA, and ASTM
Control cable conductors are assembled
with one (1) green insulated ground
conductor
SHIELDING
A bare copper tape is applied over the
cabled assembly of phase conductors and
ground wires to provide 100% coverage of
the dielectric and provide for conduction of
common mode currents.
FILLER
Solid rubber filler
ARMORING/CHEMICAL BARRIER
Prysmian patented AIRBAG™ polymeric
armor/chemical barrier
OUTER SHEATH
PVC meeting the requirements of CSA 22.2
No. 03 -40/-35 °C cold bend/cold impact
or LSZH
Oil & Gas - Cable Solutions
ICEA S-95-658 (NEMA WC70)
Pipelines & LNG - Onshore
Low Voltage & Control Cables
Low Voltage AIRGUARD
TM
VFD 0,6/1 kV
Cu/XLPE/AIRBAG
TM
/PVC or LSZH
VFD Power and Control cables 0,6/1 kV. Flame retardant, polymeric armored, PVC or LSZH jacket.
APPLICATION
Low Voltage AIRGUARD™ VFD Power cables
are designed for variable frequency drive
applications in fixed installations in the harsh
environments found in the heavy industrial
markets. Its rugged polymeric AIRBAG™ armor
and chemical barrier makes it the ideal choicefor
tough, harsh, environmental conditions.
AIRGUARD™ cables provide the solutution to
the deficiencies often encounter with Type
MC-HL cables including armor breakage during
installation, applications requiring repeated
flexing, and in areas with high vibration.
STANDARDS & APPROVALS
ASTM B3 & ASTM B8 (Conductors)
ICEA S-95-658 (NEMA WC70)
UL 44 (XHHW-2 600V)
CSA 22.2 No. 38
CSA 22.2 No. 230
CSA 22.2 No. 239 (Control Cables)
UL 1202/ FT4
CSA 22.2 No. 03 (Cold Bend/Cold Impact)
UL 2225 (TC-ER-HL Listed sizes only)
MSHA (Mine Safety & Health Administration)
1
2
3
4
6
7
5
1
3
4
5
7
6
2
CONTACT INFO:
prysmianoilandgas@prysmiangroup.com
www.prysmiangroup.com/contact-us
2
P/L LV AIRGUARD VFD - 09/2017
This product information sheet is provided for reference only.
Please consult the factory or your representative to confirm all engineering information or refer to the related catalogues available in the local countries website.
QUALITY & TESTING
Prysmian has a built-in multi-step quality assurance program, covering the production process from cable design and raw material
purchases to final inspection and testing documentation.
The ISO 9001 quality system of Prysmian Group (together with ISO 14001 and OHSAS 18001) has been assessed, approved and is currently
audited by SGS.
Oil & Gas - Cable Solutions
ICEA S-95-658 (NEMA WC70)
Pipelines & LNG - Onshore
Low Voltage & Control Cables
PERFORMANCES/RATINGS
EXCELLENT
CHEMICAL
RESISTANCE
IEEE 1202/ FT4
FIRE
BEHAVIOUR
Exceptional and vastly superior
to any metallic armoured products
IMPACTS
low
LOW EMISSION
SMOKE DENSITY,
CORROSIVITY
AND TOXICITY
+90 °C
MAX
OPERATING
TEMPERATURE
250
°C
+250 °C
SHORT
CIRCUIT
TEMPERATURE
Cold bend / Cold impact
-40 °C / -35 °C
MIN.
INSTALLATION
TEMPERATURE
Lead Free
LEAD