Article Information Sheet (AIS)
Procell Alkaline Batteries (Major and Specialty Cells)
Consumer Relations: North America
North America: 1-800-551-2355 (9:00 AM - 5:00 PM EST)
2. Company Information
3. Article Information
Duracell branded consumer alkaline battery
Electro-technical device
Description
Product Category
Sizes
Consumer Relations: E&A
(UK) 0800 716434, (FR) 0800 346 790 Service & appel gratuits,
(IRL) 1 800 509 176, (DE) 800 101 2112, (AT) 0800 1025 1956,
(CH) 0800 000 885, (BE) 0800 509 95, (NL) 0800 265 8616,
(IT) 800 125 662, (ES) 900 800 522, (PT) 800 781 012,
(GR) 210 66 75 000, (CY) 22-210900, (DK) 78734857,
(SE) 0852503857, (FI) 0942705057, (NO) 63791957,
(ZA) +27211403500, (RO) 021 3361915, (MD) 022472402,
(BG) 02 40 24 500, (BIH) 033756000, (MNE) 020261920,
(PL) 22 692 42 77, (LT) (8) 37 401 111, (LV) 67798667,
(EE) +3726505555, (CZ) +420233332010, (SK) +42153419601,
(HU) 0620 770 7099, (HR) 0800 0009, (SI) 01/588 6800,
(AZ) 812 3100949, (UA) +380444909771 П «САВ 92») & +380442476704 ОВ
«ІНВЕСТКОМ»),
(KZ) +7 727 250 05 50, (TM) 00865 530070,
(KG) 0312 41 77 04 (Apple City International),
(TR) 0 850 502 61 40.
This Article Information Sheet (AIS) provides relevant battery information to retailers, consumers, OEMs and others users
requesting a GHS-compliant SDS. Articles, such as batteries, are exempt from GHS SDS classification criteria. The GHS criteria is
not designed or intended to be used to classify the physical, health and environmental hazards of an article. Branded consumer
batteries are defined as electro-technical devices. The design, safety, manufacture, and qualification of branded consumer
batteries follow ANSI and IEC battery standards. This document is based on principles set forth in the following hazard
communication approaches: ANSI Z-400.1, GHS, JAMP AIS, IEC 62474, and ANSI C18.4M.
Duracell Industrial Operations, Inc., 14 Research Drive, Bethel, CT USA 06801. Duracell
Batteries BV, Nijverheidslaan 7, 3200 Aarschot, Belgium. Duracell International
Operations Sàrl, Rue du Pré-de-la-Bichette 1, CH-1202, Geneva, Switzerland. Suite 2.01,
Level 2 423 Pennant Hills Rd Pennant Hills, NSW 2120 Australia.
www.procell.com
1. Document Information
Global Website
Information Contact
Name & Address
Document ID
Issue Date
Version
Preparer
Last Revision
AIS-ALK
1-May-15
Document Name
6.0
Duracell North America Product Safety & Regulatory
4/30/2021
SDS@duracell.com
A battery powers a device by converting stored chemical energy into electrical energy.
Major Cells: AA, AAA, C, D & 9V
Portable power source for electronic devices
Procell, Procell Intense, Procell Intense Alkaline Battery Packs
Use
Global Branding (B2B)
Sizes
Specialty Cells: 4.5V
Sizes
Procell Intense Alkaline Battery Packs: PXBP (28110); PXBP Style F; PXBP Style B; PXBP
Style ILCO
Principles of Operation
AIS-ALK 1 of 5
Article Information Sheet (AIS)
CAN - NA/Europe
Applicable Battery Industry
Standards
ANSI C18.1M Part 1, ANSI C18.1M Part 2, ANSI C18.4M, IEC 60086-1, IEC 60086-2, IEC
60086-5
Remove to fresh air.
A damaged battery will release concentrated and caustic potassium hydroxide.
Do not induce vomiting. Seek medical attention immediately. For information on
treatment, call the National Battery Ingestion Hotline (telephone numbers for the USA
and Canada are provided below).
Flush with water for at least 15 minutes. Seek medical care if irritation persists.
Poison Center/North America
USA/Canada Calls Only: 1-800-498-8666 (Toll Free) [ 24-Hour National Battery
Ingestion Hotline]
Alkaline Manganese Dioxide
Zinc (CAS # 7440-66-6)
Manganese Dioxide (CAS # 1313-13-9)
Alkali Metal Hydroxide (aqueous potassium hydroxide - CAS # 1310-58-3)
Declarable Substances
(IEC 62474 Criteria 1)
5. Health & Safety
Nickel Cobalt Plated Steel
None
Exposure to contents inside the sealed battery will not occur unless the battery leaks, is
exposed to high temperatures, or is mechanically abused.
Electro-technical System
Small Cell or Battery
(ANSI C18.1M Part 2; IEC 60086-5)
Sizes: AAA and Specialty Cells fit inside a specially designed test cylinder 2.25 inches
(57.1mm) long by 1.25 inches (31.70 mm) wide.
Required for Small Cell or Battery (Sizes: AAA and Specialty Cells): Keep away from
children. If swallowed, consult a physician immediately.
Battery Safety Standards & Testing
Duracell batteries meet the requirements of ANSI C18. 1M Part 2 and IEC 60086-5. These
standards specify tests and requirements for alkaline batteries to ensure safe operation
under normal use and reasonably foreseeable misuse. The test regimes assess three
conditions of safety. These are:
1-Intended use simulation: Partial use, vibration, thermal shock, and mechanical shock
2-Reasonably foreseeable misuse: Incorrect installation, external short-circuit, free fall
(user-drop), over-discharge, and crush
3-Design consideration: Thermal abuse, mold stress
First Aid - Skin Contact
First Aid - Inhalation
Remove contaminated clothing. Wash skin with soap and water. Seek medical care if
irritation persists.
Electrode - Negative
Electrode - Positive
Electrolyte
Yes
CAN/China
Nickel Colbalt Plated Steel or Mickel Plated Steel
First Aid - If swallowed
First Aid - Eye Contact
Mercury Free Battery
(ANSI C18.4M <5ppm)
Ingestion/Small Parts Warning
Normal Conditions of Use
Note to Physician
Poison Centers/World Directory
https://globalcrisis.info/poisonemergency.html#AAA
4. Article Construction
Representative Product Images -
Major Cells
AIS-ALK 2 of 5