User’s
Manual
Yo kogawa Electric Corporation
MX100/MW100
Data Acquisition Unit
Installation and Connection Guide
Foreword
Thank you for purchasing the MX100/MW100 Data Acquisition Unit. This guide describes concisely the installation and wiring procedures of
the MX100/MW100 Data Acquisition Unit. For more details on this topic as well as safety precautions (be sure to read), and the descriptions
of the functions and operations of the MX100/MW100 Data Acquisition Unit, see the MX100/MW100 Data Acquisition Unit User’s Manual
(electronic manual in PDF format) which is contained in the CD-ROM provided.
1. Installation Procedure
of Modules
3. Terminal Arrangement Markings
4. Attaching and Removing the Terminal Block
Screw Terminal Block
Plate with screw terminals
5. Wiring Procedure
6. Connecting the Power Supply
Inserting and Ejecting the CF Card
7. Connecting to the Ethernet Interface
Contents Displayed on the 7-Segment LED
Dipswitches
*1
MX100
Types of Input/Output Modules
• 4-CH, High-Speed Universal Input Module (MX110-UNV-H04) • 10-CH, Medium-Speed Universal Input Module (MX110-UNV-M10)
30-CH, Medium-Speed DCV/TC/DI Input Module (MX110-VTD-L30)
6-CH, Medium-Speed Four-Wire RTD Resistance Input Module (MX110-V4R-M06)
• 4-CH, Medium-Speed Strain Input Module (MX112-B12-M04) • 4-CH, Medium-Speed Strain Input Module (MX112-B35-M04)
• 4-CH, Medium-Speed Strain NDIS Input Module (MX112-NDI-M04) • 10-CH, Pulse Input Module
*2
(MX114-PLS-M10)
• 10-CH, High-Speed Digital Input Module (MX115-D05-H10) • 10-CH, High-Speed Digital Input Module (MX114-D24-H10)
• 8-CH, Medium-Speed Analog Output Module (MX120-VAO-M08) • 8-CH, Meduim-Speed PWM Output Module (MX120-PWM-M08)
• 10-CH, Medium-Speed Digital Output Module (MX125-MKC-M10)
Main module
*2 Modules compatible with the MW100.
*1 Normally all dip switches are turned ON.
Used to initialize settings and for other purposes.
The figure on the left is the MX100 Main Module.
This is different from the overview of the MW100
Main Module. On the MW100, it is dip switch 1.
2. Installation Procedure
of the MX100/MW100
Overview of the Operation
1. Installation Procedure of Modules
Attaching the Module
1. Prepare the base block.
When attaching the MW100, replace the current base block BRACKET with the BRACKET that came with the MW100.
Attach the bracket that came with the MW100
Remove the base block bracket
Bracket
When attaching the MX100, if using a conventional version of the main module, remove the base block BRACKET. If the main module has
been reworked, use the existing base block as-is. See “MX100/MW100: Handling of the Base Block (Model MX150-)” in IM MX100-75.
2. Check that the power supply is not connected to the main module.
7th Edition: February 2008 (YK)
All Right Reserved, Copyright © 2005 Yokogawa Electric Corporation
IM MX100-72E
7th Edition
*MX10072E07 *
2
IM MX100-72E
3. Align the connector on the rear panel of the module to the connector at the desired position of the base plate and insert the connector.
When the connectors are correctly connected, the guide pin on the rear panel of the module is inserted into the guide hole on the base
plate. Then, the module is secured to the base plate with the latch lever locking in place at the bottom section of the base plate.
Note that the main module can only be attached to the right end of the base plate.
4. For the MX100 main module, attach using a screw (M3) at the top of the module.
For the MW100 main module, attach using screws (M3) in two locations at the top of the module.
Base plate connector cover
*1
(accessory sold separately)
Input/Output module
Module attachment screw
Module connector
*2
Screw holes
Guide holes
MX100
Main module
Base plate
Base plate
Latch lever
(Pull up to remove the module from the base plate.)
Guide pins
MW100
Main module
Screw holes
Guide holes
Module connector
*2
Base plate
Base plate connector cover
*1
(accessory sold separately)
Input/Output module
Module attachment screw
Base plate
Latch lever
(Pull up to remove the module from the base plate.)
Guide pins
MX100 Main module
MW100 Main module
*1 Can be attached by hooking the top section of the cover to the top edge of the base plate and pressing down on the lower section of the
cover
When attaching the module, be sure that the module
connector is vertical to the base plate so that the
module connector pins are not bent.
*2
Detaching the Module
Loosen the attachment screw, pull down on the latch lever on the rear panel of the module, and pull the module straight from the base
plate.
Attachment Positions and Channel Numbers
The figure below shows how the channel numbers are identified on the PC. The MW100 channel numbers are only displayed when
viewing measured data on the MW100 Viewer software.
MX100
0
1
2
3
4
5
Slot number
001 to 010
011 to 020
021 to 030
031 to 040
041 to 050
051 to 060
Channel number in the unit
*2
Representation of
channel numbers:
Unit number
*1
Unit number
MX100: 00 to 19
MW100: 00 to 89
*2 The last one digit on a 4-channel module is 1 to 4,
the last one digit on a 6-channel module is 1 to 6,
the last one digit on a 8-channel module is 1 to 8.
Channel number in
the unit (001 to 060)
*1 Fixed to 00 when connecting using the MX100
Standard software; set between 00 and 19 when
using MXLOGGER software; and set between 00
and 89 when using the MW100 Viewer software.
Note
The 30-CH Medium Speed DCV/TC/DI Input Module takes up three modules worth of space when attaching to the
base plate.
1. Installation Procedure of Modules