RT Series, Single Phase
1/2/3 kVA
Reliable power with greater energy-saving features
Availability
Green & Low TCO
Flexibility
True online double-conversion topology and zero
transfer time to battery ensure high reliability
Watch-dog design of DSP (Digital Signal Processor)
increases reliability
Cold-start capability provides temporary battery power
when the utility power is out
Fan failure detection alerts users to failed fans
Hot swappable batteries ensure continuous operation
even when batteries are being replaced
Optional external battery pack for easy scaling of
longer backup time
• Operation temperature tolerance up to 50°C ensures
critical loads' continuity
• High output power factor 0.9 provides more real power to critical loads
• High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 5%) save upstream investment
• Up to 94% AC-AC efficiency and 97% efficiency in ECO mode result in marked energy cost savings
• Wide input voltage range reduces the chance of using the battery and extends battery life
• Intelligent battery management sustains battery life and performance
• Fan speed control by load level maximizes efficiency and reduces audible noise
• Load segment control allows less-critical loads to be disconnected during blackouts and
saves battery runtime for important loads
• Convertible rack and tower configuration in 2U size cabinet
• Excellent local communications through rotatable LCD display
• Intelligent management software connectivity via RS232 or USB port
The Amplon RT 1-3kVA series is an online double-conversion UPS providing consistent sine-wave power to your critical equipment.
It supports personal computers, networks, servers, VoIP and telecommunications. The Amplon RT 1-3kVA series features an output
power factor of 0.9 and best-in-class AC-AC efficiency up to 94% resulting in greater energy savings. Optional external battery pack
can be connected for longer backup time to keep your applications safe and running smoothly at all times.
StorageVolP
Leaflet_UPS_RT1--3kVA_en-us_V5
Delta’s Manufacturing
System is Certified by
ISO 9001 and ISO 14001
Standards
IACQ Certificate of
Hazardous Substance
Process Management
Delta UPS - Amplon Family
RT Series, Single Phase
1/2/3 kVA
Model
* When the UPS i
s de-rated to 90% of its capacity.
** When the total load reaches 75%.
*** 40~50°C with 80% de-rating.
All specifications are subject to change without prior notice.
1kVA/0.9kW
200*/208*/220/230/240Vac
175~280Vac (full load); 120~175Vac (70~100% load)
40~70Hz
> 0.99 (full load)
< 5%
0.9
200*/208*/220/230/240Vac
± 1% (linear load)
50/60Hz ± 0.05Hz
< 2% (linear load)
< 105%: Continuous; 105~125%: 1 minute; 125~150%: 15 seconds
IEC C13 x 6
90%
96%
24Vdc
6.5 minutes
1.5A
3 hours to 90%
< 40dB
LCD display and LED indicators
SMART Slot x 1, RS-232 Port x 1, USB Port x 1, REPO x 1
CE, TISI, RCM, EAC
440 x 335 x 89mm
440 x 335 x 89mm
12kg
15kg
0~50°C***
5~95% (non-condensing)
RT-1K
Nominal Voltage
Voltage range
Frequency
Power Factor
Current Harmonic Distortion
Power Factor
Voltage
Voltage Regulation
Frequency
Voltage Harmonic Distortion
Overload Capability
Receptacle
AC-AC
ECO Mode
Battery Voltage
Typical Backup Time**
Charge Current
Recharge Time
UPS
External Battery Pack
UPS
External Battery Pack
Operating Temperature
Relative Humidity
RT-3K
3kVA/2.7kW
72V
dc
<
46dB
440 x
610 x 89mm
440 x 610 x 89mm
28k
g
44k
g
RT-2K
2kVA/1.8kW
IEC C13 x 6, IEC C19 x 1
Up to 94%
Up to 97%
48V
dc
7 minutes
2A
<
43dB
440 x
432 x 89mm
440 x 432 x 89mm
18k
g
27k
g
Power Rating
Input
Output
Efficiency
Battery
Audible Noise
Display
Interfaces
Conformance
Dimensions (W x D x H)
Weight
Environment
Model