MBU100 SERIES
DC-DC CONVERTER 1W, SIP-Package
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2021/09/16 REV:8 Page 1 of 4
FEATURES
Industrial Standard SIP-4 Package
Unregulated Output Voltage
I/O Isolation 1000 VDC
Operating Ambient Temp. Range -40 to +85
PRODUCT OVERVIEW
The MINMAX MBU100 series is a range of 1W DC-DC converters in a miniature SIP Package featuring I/O isolation of 1000VDC. A high efficiency allows
an operating temperature range of -40 to +85. These converters offer an economical solution for many space critical applications where a voltage has
to be isolated i.e for noise reduction, ground loop elimination, digital interfaces or for board level power distribution.
Model Selection Guide
Model
Number
Input
Voltage
(Range)
Output
Voltage
Output Current Input Current Load
Regulation
Max. capacitive
Load
Efficiency
(typ.)
Max.
Min.
@Max. Load
@Max. Load
VDC
VDC
mA
mA
mA(typ.)
% (max.)
μF
%
MBU135
3.3
(2.97 ~ 3.63)
3.3
260
6
351
35
14
33
74
MBU131
5
200
4
394
14
77
MBU105
5
(4.5 ~ 5.5)
3.3
260
6
238
30
11
33
72
MBU101
5
200
4
290
11
69
MBU102
9
110
2
260
8
76
MBU103
12
84
1.5
262
7
77
MBU104
15
67
1
258
6
78
MBU111
12
(10.8 ~ 13.2)
5
200
4
117
13
9
33
71
MBU112
9
110
2
107
5
77
MBU113
12
84
1.5
106
5
79
MBU114
15
67
1
105
4
80
MBU121
24
(21.6 ~ 26.4)
5
200
4
60
7
8
33
70
MBU122
9
110
2
54
5
76
MBU123
12
84
1.5
53
4
79
MBU124
15
67
1
53
4
79
* Min. Output Current for Lower Load Regulation
Input Specifications
Parameter
Model
Min.
Typ.
Max.
Unit
Input Voltage Range
3.3V Input Models
2.97
3.3
3.63
VDC
5V Input Models
4.5
5
5.5
12V Input Models
10.8
12
13.2
24V Input Models
21.6
24
26.4
Input Surge Voltage (1 sec. max.)
3.3V Input Models
-0.7
---
6
5V Input Models
-0.7
---
9
12V Input Models
-0.7
---
18
24V Input Models
-0.7
---
30
Input Filter
Internal Capacitor
MBU100 SERIES
DC-DC CONVERTER 1W, SIP-Package
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2021/09/16 REV:8 Page 2 of 4
Output Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Output Voltage Setting Accuracy
---
±1.0
±3.0
%Vnom.
Line Regulation
For Vin Change of 1%
---
±1.2
±1.5
%
Load Regulation
Io=20% to 100%
See Model Selection Guide
Ripple & Noise
0-20 MHz Bandwidth
---
100
150
mV
P-P
Temperature Coefficient
---
±0.01
±0.02
%/
Short Circuit Protection
0.5 Second Max., Automatic Recovery
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
60 Seconds
1000
---
---
VDC
1 Seconds
1200
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100kHz, 1V
---
60
100
pF
Switching Frequency
50
90
110
kHz
MTBF (calculated)
MIL-HDBK-217F@25, Ground Benign
2,000,000
Hours
Environmental Specifications
Parameter
Min.
Max.
Unit
Operating Ambient Temperature Range (See Power Derating Curve)
-40
+85
Case Temperature
---
+90
Storage Temperature Range
-50
+125
Humidity (non condensing)
---
95
% rel. H
Lead Temperature (1.5mm from case for 10Sec.)
---
260
Power Derating Curve
(5V Output Only)
(All Other Output)
Notes
1
Specifications typical at Ta=+25, resistive load, nominal input voltage and rated output current unless otherwise noted.
2 These power converters require a minimum output loading to maintain specified regulation, operation under no-load conditions will not damage these
modules; however they may not meet all specifications listed.
3
We recommend to protect the converter by a slow blow fuse in the input supply line.
4
Other input and output voltage may be available, please contact MINMAX.
5
Specifications are subject to change without notice.