MKW40 SERIES
DC-DC CONVERTER 40W, Highest Power Density
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2021/06/07 REV:23 Page 1 of 8
®
FEATURES
Smallest Encapsulated 40W Converter
Compact Size of 2" X 1" Package
Wide 2:1 Input Voltage Range
Fully Regulated Output Voltage
Excellent Efficiency up to 92%
I/O Isolation 1500 VDC
Operating Ambient Temp. Range -40 to +80
No Min. Load Requirement
Overload/Voltage/Temp. and Short Circuit Protection
Remote On/Off Control, Output Voltage Trim
Shielded Metal Case with Insulated Baseplate
UL/cUL/IEC/EN 62368-1(60950-1) Safety Approval
PRODUCT OVERVIEW
The MINMAX MKW40 series is a generation of high performance DC-DC converter modules. The product offers fully 40W in an encapsulated, shielded
metal package with dimensions of just 2.0"x1.0"x0.4". All models provide wide 2:1 input voltage range and precisely regulated output voltages. Advanced
circuit topology provides a very high efficiency up to 92% which allows an operating temperature range of -40 to +80. Further features include remote
On/Off, trimmable output voltage, under-voltage shutdown as well as overload and over-temperature protection. Typical applications for these converters
are battery operated equipment, instrumentation, distributed power architectures in communication and industrial electronics and many other space critical
applications.
Model Selection Guide
Model
Number
Input
Voltage
(Range)
Output
Voltage
Output Current Input Current Reflected
Ripple
Current
Over
Voltage
Protection
Max. capacitive
Load
Efficiency
(typ.)
Max.
@Max. Load
@No Load
@Max. Load
VDC
VDC
mA
mA(typ.)
mA(typ.)
mA (typ.)
VDC
μF
%
MKW40-12S033
12
(9 ~ 18)
3.3
8000
2470
120
50
3.9
21000
89
MKW40-12S05
5
8000
3750
160
6.2
13600
89
MKW40-12S12
12
3330
3750
160
15
2400
89
MKW40-12S15
15
2670
3700
150
18
1500
90
MKW40-12S24
24
1670
3670
160
30
600
91
MKW40-12D12
±12
±1670
3790
70
±15
1200#
88
MKW40-12D15
±15
±1330
3790
60
±18
750#
88
MKW40-24S033
24
(18 ~ 36)
3.3
8000
1220
75
30
3.9
21000
90
MKW40-24S05
5
8000
1830
80
6.2
13600
91
MKW40-24S12
12
3330
1830
85
15
2400
91
MKW40-24S15
15
2670
1830
75
18
1500
91
MKW40-24S24
24
1670
1835
85
30
600
91
MKW40-24D12
±12
±1670
1870
50
±15
1200#
89
MKW40-24D15
±15
±1330
1870
45
±18
750#
89
MKW40-48S033
48
(36 ~ 75)
3.3
8000
610
40
20
3.9
21000
90
MKW40-48S05
5
8000
920
50
6.2
13600
91
MKW40-48S12
12
3330
910
50
15
2400
92
MKW40-48S15
15
2670
910
50
18
1500
92
MKW40-48S24
24
1670
918
50
30
600
91
MKW40-48D12
±12
±1670
940
65
±15
1200#
89
MKW40-48D15
±15
±1330
940
65
±18
750#
89
# For each output
MKW40 SERIES
DC-DC CONVERTER 40W, Highest Power Density
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2021/06/07 REV:23 Page 2 of 8
®
Input Specifications
Parameter
Conditions / Model
Min.
Typ.
Max.
Unit
Input Surge Voltage (1 sec. max.)
12V Input Models
-0.7
---
25
VDC
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
Start-Up Threshold Voltage
12V Input Models
---
---
9
24V Input Models
---
---
18
48V Input Models
---
---
36
Under Voltage Shutdown
12V Input Models
---
8.3
---
24V Input Models
---
16.5
---
48V Input Models
---
33
---
Start Up Time
Power Up
Nominal Vin and Constant Resistive Load
---
---
30
ms
Remote On/Off
---
---
30
ms
Input Filter
All Models
Internal LC Type
Remote On/Off Control
Parameter
Conditions
Min.
Typ.
Max.
Unit
Converter On
3.5V ~ 12V or Open Circuit
Converter Off
0V ~ 1.2V or Short Circuit
Control Input Current (on)
Vctrl = 5.0V
---
0.5
---
mA
Control Input Current (off)
Vctrl = 0V
---
-0.5
---
mA
Control Common
Referenced to Negative Input
Standby Input Current
Nominal Vin
---
2.5
---
mA
Output Specifications
Parameter
Conditions / Model
Min.
Typ.
Max.
Unit
Output Voltage Setting Accuracy
---
---
±1.0
%Vnom.
Output Voltage Balance
Dual Output, Balanced Loads
---
---
±2.0
%
Line Regulation
Vin=Min. to Max. @Full Load
---
---
±0.5
%
Load Regulation Min. Load to Full Load
Single Output
---
---
±0.5
%
Dual Output
---
---
±1.0
%
Load Cross Regulation (Dual Output)
Asymmetrical Load 25%/100% Full Load
---
---
±5.0
%
Minimum Load
No Minimum Load Requirement for Single Output Models, for dual Output Models see Table
Ripple & Noise 0-20 MHz Bandwidth
3.3V & 5V Output Models
---
100
---
mV
P-P
12V, 15V & 24V Models
---
150
---
mV
P-P
Dual Output Models
---
150
---
mV
P-P
Transient Recovery Time
25% Load Step Change
---
250
---
μsec
Transient Response Deviation
---
±3
±5
%
Temperature Coefficient
---
---
±0.02
%/
Trim Up / Down Range (See Page 6)
% of Nominal Output Voltage
24Vo Models
---
---
+20 / -10
%
Other Models
---
---
±10
Over Current Protection
Current Limitation at 150% typ. of Iout max., Hiccup
Short Circuit Protection
24Vo Models
Continuous, Automatic Recovery (Hiccup Mode 0.3Hz typ.)
Other Models
Continuous, Automatic Recovery (Hiccup Mode 1.5Hz typ.)
General Specifications
Parameter
Conditions / Model
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
60 Seconds
1500
---
---
VDC
1 Seconds
1800
---
---
VDC
I/O Isolation Resistance
500 VDC
1000
---
---
MΩ
I/O Isolation Capacitance
100kHz, 1V
---
---
1500
pF
Switching Frequency
24Vo Models
---
285
---
kHz
Other Models
---
320
---
kHz
MTBF(calculated)
MIL-HDBK-217F@25, Ground Benign
328,000
Hours
Safety Approvals
UL/cUL 60950-1 recognition(CSA certificate), IEC/EN 60950-1(CB-report)
UL/cUL 62368-1 recognition(UL certificate), IEC/EN 62368-1(CB-report)