MKE20-HI SERIES
DC-DC CONVERTER 20W, Ultra-High Isolation, 2"×1" Package
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2020/09/03 REV:5 Page 1 of 6
®
FEATURES
Industrial Standard 2"x1" Package
Wide 2:1 Input Voltage Range
Fully Regulated Output Voltage
Ultra-high I/O Isolation 8000VDC with Reinforced Insulation, rated for
1000Vrms Working Voltage
Operating Ambient Temp. Range -40 to +80
No Min. Load Requirement
Under-voltage, Overload/Voltage and Short Circuit Protection
EMI Emission EN55032 Class A Approved
UL/cUL/IEC/EN 62368-1(60950-1) Safety Approval & CE Marking
PRODUCT OVERVIEW
The MINMAX MKE20-HI series is a range of high performance 20W DC-DC converter within encapsulated 2"x1" package which specifically design for high
isolation applications where reinforced insulation and high working voltage are required. There are 21 models available for input voltage of 12, 24, 48VDC
with wide 2:1 input range and fixed output voltage. The I/O isolation is specified for 8000VDC with reinforced insulation, which rated for 1000Vrms working
voltage. Further features include under-voltage, overload, over voltage, short circuit protection, no min. load requirement, EMI emission EN 55032 Class A
approved, low I/O capacitance 80pF max. and operating ambient temp. range by -40
to 80 by high efficiency up to 90%. MKE20-
HI series conform to
UL/cUL/IEC/EN 62368-1 (60950-1) safety approvals. The MKE20-HI series offer a superior solution for demanding application in requesting a certified
supplementary.
Model Selection Guide
Model Number
Input
Voltage
(Range)
Output
Voltage
Output Current
Reflected
Ripple
Current
Over
Voltage
Protection
Max. capacitive
Load
Efficiency
(typ.)
Max.
@Max. Load
@No Load
@Max. Load
VDC
VDC
mA
mA(typ.)
mA (typ.)
mA(typ.)
VDC
μF
%
MKE20-12S05HI
12
(9 ~ 18)
5
4000
1961
20 100
6.2
6800
85
MKE20-12S051HI
5.1
4000
2000
6.2
85
MKE20-12S12HI
12
1670
1898
15
1160
88
MKE20-12S15HI
15
1333
1893
18
750
88
MKE20-12S24HI
24
840
1888
27
295
89
MKE20-12D12HI
±12
±
840
1888
±15
590#
89
MKE20-12D15HI
±15
±670
1882
±18
380#
89
MKE20-24S05HI
24
(18 ~ 36)
5
4000
958
15 50
6.2
6800
87
MKE20-24S051HI
5.1
4000
977
6.2
87
MKE20-24S12HI
12
1670
949
15
1160
88
MKE20-24S15HI
15
1333
936
18
750
89
MKE20-24S24HI
24
840
933
27
295
90
MKE20-24D12HI
±12
±840
933
±15
590#
90
MKE20-24D15HI
±15
±
670
931
±18
380#
90
MKE20-48S05HI
48
(36 ~ 75)
5
4000
479
10 30
6.2
6800
87
MKE20-48S051HI
5.1
4000
489
6.2
87
MKE20-48S12HI
12
1670
474
15
1160
88
MKE20-48S15HI
15
1333
463
18
750
90
MKE20-48S24HI
24
840
472
27
295
89
MKE20-48D12HI
±12
±
840
472
±15
590#
89
MKE20-48D15HI
±15
±
670
465
±18
380#
90
# For each output
MKE20-HI SERIES
DC-DC CONVERTER 20W, Ultra-High Isolation, 2"×1" Package
E-mail:sales@minmax.com.tw Tel:886-6-2923150
2020/09/03 REV:5 Page 2 of 6
®
Input Specifications
Parameter
Conditions / Model
Min.
Typ.
Max.
Unit
Input Surge Voltage (100 ms max.)
12V Input Models
-0.7
---
25
VDC
24V Input Models
-0.7
---
50
48V Input Models
-0.7
---
100
Start-Up Threshold Voltage
12V Input Models
---
---
9
24V Input Models
---
---
18
48V Input Models
---
---
36
Under Voltage Shutdown
12V Input Models
---
7.5
---
24V Input Models
---
15
---
48V Input Models
---
33
---
Start Up Time (Power On)
Nominal Vin and Constant Resistive Load
---
---
30
ms
Input Filter
All Models
Internal Pi Type
Output Specifications
Parameter
Conditions / Model
Min.
Typ.
Max.
Unit
Output Voltage Setting Accuracy
---
---
±1.0
%Vnom.
Output Voltage Balance
Dual Output, Balanced Loads
---
---
±2.0
%
Line Regulation
Vin=Min. to Max. @Full Load
---
---
±0.5
%
Load Regulation Io=0% to 100%
Single Output
---
---
±0.5
%
Dual Output
---
---
±1.0
%
Minimum Load
No minimum Load Requirement
Ripple & Noise
0-20 MHz
Bandwidth
5V & 5.1Vo
Measured with a
MLCC : 4.7μF
---
50
---
mV
P-P
12V,15V, ±12V, ±15Vo
---
100
---
mV
P-P
24Vo
---
150
---
mV
P-P
Transient Recovery Time
25% Load Step Change
(2)
---
---
300
μsec
Transient Response Deviation
---
±3
±5
%
Temperature Coefficient
---
---
±0.02
%/
Over Load Protection
Hiccup
---
150
---
%
Short Circuit Protection
Continuous, Automatic Recovery (Hiccup Mode 0.7Hz typ.)
Isolation, Safety Standards
Parameter
Conditions
Min.
Typ.
Max.
Unit
I/O Isolation Voltage
60 Seconds
Reinforced insulation, rated for 1000Vrms working voltage
4200 --- --- VAC
Tested for 1 second
8000
---
---
VDC
I/O Isolation Resistance
500 VDC
10
---
---
GΩ
I/O Isolation Capacitance
100kHz, 1V
---
---
80
pF
Safety Approvals
UL/cUL 60950-1 recognition (UL certificate), IEC/EN 60950-1 (CB-report)
UL/cUL 62368-1 recognition (UL certificate), IEC/EN 62368-1 (CB-report)
General Specifications
Parameter
Conditions
Min.
Typ.
Max.
Unit
Switching Frequency
---
285
---
kHz
MTBF(calculated)
MIL-HDBK-217F@25, Ground Benign
1,087,344
---
---
Hours