Page 1
www.sensata.com
Copyright © 2018 Sensata Technologies, Inc.
EL SERIES | AC OUTPUT
PANEL MOUNT SOLID STATE RELAYS
PRODUCT SELECTION
Features
Ratings of 5A, 10A, 20A and 30A @ 24-280 VAC
UL Recognized, TUV, CE and RoHS Compliant.
5, 12 and 24 VDC control input options
Zero voltage or instantaneous turn-on outputs
LED input status indicator
Thermal Pad Included
Control Voltage 5 A 10 A 20 A 30 A
4-8 VDC
EL240A5-05 EL240A10-05 EL240A20-05 EL240A30-05
10-14 VDC
EL240A5-12 EL240A10-12 EL240A20-12 EL240A30-12
21-27 VDC
EL240A5-24 EL240A10-24 EL240A20-24 EL240A30-24
Page 2
www.sensata.com
Copyright © 2018 Sensata Technologies, Inc.
Input
(3)
Description EL240Axx-05 EL240Axx-12 EL240Axx-24
Control Voltage Range
4-8 VDC 10-14 VDC 21-27 VDC
Minimum Turn-On Voltage
4 VDC 10 VDC 21 VDC
Must Turn-Off Voltage
1 VDC 1 VDC 1 VDC
Minimum Input Current
6 mA 10 mA 8 mA
Maximum Input Current
21 mA 17.50 mA 19 mA
Maximum Turn-On Time [msec]
(5)
1/2 Cycle 1/2 Cycle 1/2 Cycle
Maximum Turn-Off Time [msec]
1/2 Cycle 1/2 Cycle 1/2 Cycle
General
(2)
Description Parameters
Dielectric Strength, Input to Output (50/60Hz)
3750 Vrms
Dielectric Strength, Output to Baseplate (50/60Hz)
2500 Vrms
Maximum Capacitance, Input/Output
8 pF
Ambient Operating Temperature Range
-30 to 80°C
Ambient Storage Temperature Range
-30 to 125 °C
Weight (typical)
0.5 oz (14.4 g)
Terminals
3/16”x 0.032” input, 1/4”x 0.032” output QC
SSR Mounting Screw Torque Range
9.0-10.0 lb-in (1.0-1.13 Nm)
LED Input Status Indicator
Green
Humidity per IEC60068-2-78
93% non-condensing
Output
(3)
Description 5 A 10 A 20 A 30 A
Operating Voltage (47-63Hz) [Vrms]
24-280 24-280 24-280 24-280
Maximum Load Current [Adc]
(4)
5 10 20 30
Minimum Load Current [mArms]
150 150 250 250
Transient Overvoltage [Vpk]
(2)
600 600 600 600
Maximum Surge Current (50/60Hz, 1 Cycle) [Apk]
115/120 145/150 240/250 260/280
Maximum I²t for Fusing (50/60Hz 1/2 cycle) [A² sec]
65/60 100/95 285/260 338/326
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/μsec]
500 500 500 500
Maximum Off-State Leakage Current @ Rated Voltage [mArms]
0.1 0.1 0.1 0.1
Thermal Resistance Junction to Case (Rjc) [°C/W]
5.5 3.0 1.7 0.9
Maximum On-State Voltage Drop @ Rated Current [Volts]
1.3 1.3 1.3 1.3
Minimum Power Factor (with Maximum Load)
(1)
0.7 0.7 0.7 0.7
SPECIFICATIONS