This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at https://www.sgs.com.tw/terms-of-service
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com.tw/terms-of-service. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of clients instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested.
No. 61, Kai-Fa Road, Nanzih Export Processing Zone , Kaohsiung, Taiwan
/
高雄楠梓工出區開發路61
Member of the SGS Group
Page: 1 of 18
:
:
:
:
:
============================================================================================
(1)
(2)
(1)
No. : KA/2020/80072 Date : 2020/08/18
Test Report
2020/08/03 to 2020/08/18
2020/08/03
29 PANDAN CRESCENT, SINGAPORE 128473
TANAKA ELECTRONICS SINGAPORE PTE LTD.
Sample Description
Color
Au ALLOY BONDING WIRE
GOLD
The following sample(s) was/were submitted and identified by/on behalf of the client as :
Please refer to next page(s).
Test Result(s)
TANAKA ELECTRONICS SINGAPORE PTE LTD.
Sample Receiving Date
Testing Period
Sample Submitted By
Conclusion
Test Requested
As specified by client, with reference to RoHS 2011/65/EU Annex II and amending
Directive (EU) 2015/863 to determine Cadmium, Lead, Mercury, Cr(VI), PBBs, PBDEs,
DBP, BBP, DEHP, DIBP contents in the submitted sample(s).
Please refer to next pages for the other item(s).
PIN CODE: D5E4041E
Based on the performed tests on submitted sample(s), the test results of Cadmium,
Lead, Mercury, Cr(VI), PBBs, PBDEs, DBP, BBP, DEHP, DIBP comply with the limits
as set by RoHS Directive (EU) 2015/863 amending Annex II to Directive 2011/65/EU.
For Question Please
Contact with SGS
www.sgs.com.tw
Signature Not Verified
This document is issued by the Company subject to its General Conditions of Service printed overleaf, available on request or accessible at https://www.sgs.com.tw/terms-of-service
and, for electronic format documents, subject to Terms and Conditions for Electronic Documents at https://www.sgs.com.tw/terms-of-service. Attention is drawn to the limitation of
liability, indemnification and jurisdiction issues defined therein. Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its
intervention only and within the limits of clients instruction, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from
exercising all their rights and obligations under the transaction documents. This document cannot be reproduced, except in full, without prior written approval of the Company. Any
unauthorized alteration, forgery or falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested.
No. 61, Kai-Fa Road, Nanzih Export Processing Zone , Kaohsiung, Taiwan
/
高雄楠梓工出區開發路61
Member of the SGS Group
Page: 2 of 18
No. : KA/2020/80072 Date : 2020/08/18
Test Report
29 PANDAN CRESCENT, SINGAPORE 128473
TANAKA ELECTRONICS SINGAPORE PTE LTD.
:
Result
No.1
mg/kg With reference to IEC 62321-5: 2013
and performed by ICP-OES.
2 n.d. 100
mg/kg With reference to IEC 62321-5: 2013
and performed by ICP-OES.
2 n.d. 1000
mg/kg With reference to IEC 62321-4:2013+
AMD1:2017 and performed by ICP-
OES.
2 n.d. 1000
µg/cm² With reference to IEC 62321-7-1:2015
and performed by UV-VIS.
0.10 n.d. -
mg/kg - n.d. 1000
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg - n.d. 1000
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
mg/kg 5 n.d. -
LimitMDLMethod
Decabromodiphenyl ether
Tetrabromodiphenyl ether
Pentabromodiphenyl ether
With reference to IEC 62321-6:2015
and performed by GC/MS.
PART NAME NO.1 Au ALLOY BONDING WIRE
Test Result(s)
Hexabromodiphenyl ether
Heptabromodiphenyl ether
Octabromodiphenyl ether
Nonabromodiphenyl ether
Sum of PBDEs
Monobromodiphenyl ether
Dibromodiphenyl ether
Tribromodiphenyl ether
UnitTest Item (s)
Cadmium (Cd)
Lead (Pb)
Mercury (Hg)
Hexavalent Chromium Cr(VI)(#2)
Sum of PBBs
Monobromobiphenyl
Dibromobiphenyl
Tribromobiphenyl
Tetrabromobiphenyl
Pentabromobiphenyl
Hexabromobiphenyl
Heptabromobiphenyl
Octabromobiphenyl
Nonabromobiphenyl
Decabromobiphenyl