MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Rating 25 C ambient temperature uniess otherwies specified.
Single phase half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
TYPE NUMBER
Maximum Recurrent Peak Reverse Voltage
Maximum RMS Voltage
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
Peak Forward Surge Current, 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Maximum Instantaneous Forward Voltage at 10A
Maximum DC Reverse Current Ta=25 C
at Rated DC Blocking Voltage Ta=100 C
Typical Junction Capacitance (Note1)
10
150
0.02
2
2.5
A
A
V
mA
mA
pF
UNITS
Typical Thermal Resistance R JC (Note 2)
420
MBR1020CT MBR1045CT MBR1060CT MBR1080CT MBR10100CT MBR10150CTMBR10200CT
-65 +175
-65 +175
NOTES:
1. Measured at 1MHz and applied reverse voltage of 4.0V D.C.
2. Thermal Resistance Junction to Case.
20 to 200 Volts
CURRENT
10.0 Amperes
Operating
Storage Temperature Range TSTG
Temperature Range TJ
C
C
C
/W
at Tc=125 C
REV 1.0 2015 JAN
PAGE:1/2
REV 1.0 2015 JAN
PAGE:1/2
VOLTAGE RANGE
10.0 AMP SCHOTTKY BARRIER RECTIFIERS
THRU
MBR1020CT MBR10200CT
V
V
V
14 32 42 56 70 105 140
20 45 60 80 100 150 200
20 45 60 80 100 150 200
0.55 0.7 0.85 0.920.55 0.7 0.85 0.92
FEATURES
MECHANICAL DATA
* Low forward voltage drop
* High current capability
* High reliability
* High surge current capability
* Good for switching mode application
* Case: Molded plastic
* Epoxy: UL 94V-0 rate flame retardant
* Lead: Lead solderable per MIL-STD-202,
method 208 guranteed
* Polarity: As Marked
* Mounting position: Any
TO-220AB
Dimensions in inches and (millimeters)
.412
.248
.180
.050
.120
.158
.595
.550
.100
.051
.040
.108
(10.5)
(6.3)
(4.6)
(1.27)
(3.05)
(4.0)
(15.1)
(14.0)
(2.54)
(1.3)
(1.0)
(2.75)
MAX.
MAX.
MAX.
MIN.
MAX.
MAX.
3.8 +.2
HOLE THRU
f
+
PIN 1
PIN 3
PIN 2
CASE
Positive CT
Suffix "C"
0.1
5
RATING AND CHARACTERISTIC CURVES (MBR1020CT THRU MBR10200CT)
FIG.3-MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
FIG.4-TYPICAL JUNCTION CAPACITANCE
REVERSE VOLTAGE,(V)
JUNCTION CAPACITANCE,(pF)
1000
1200
1400
800
600
400
200
0
.01 .05 .1 .5 1 5 10 50 100
.1 .3 .5 .7 .9 1.1 1.3 1.5
.1
1.0
10
100
FIG.5 - TYPICAL REVERSE
CHARACTERISTICS
REVERSE LEAKAGE CURRENT, (mA)
0 20 40 60 80 100 120 140
.01
Tj=75 C
Tj=100 C
Tj=25 C
100
50
0
150
250
200
NUMBER OF CYCLES AT 60Hz
1 10 5
50
100
Tj=25 C
8.3ms Single Half
Sine Wave
JEDEC method
PERCENT OF RATED PEAK REVERSE VOLTAGE,(%)
PEAK FORWARD SURGE CURRENT,(A)
PAGE:2/2
REV 1.0 2015 JAN
FIG.1-TYPICAL FORWARD CURRENT DERATING CURVE
AVERAGE FORWARD CURRENT,(A)
2
4
6
8
10
12
0
0 20 40 60 80 100 120 140 160 180 200
CASE TEMPERATURE,( C)
0.1
1.0
.01
10
50
INSTANTANEOUS FORWARD CURRENT,(A)
FORWARD VOLTAGE,(V)
Pulse Width 300us
1% Duty Cycle
.1 .3 .5 .7 .9 1.1 1.3 1.5
5.0
MBR1080CT - MBR10100CT
MBR1020CT - MBR1045CT
Tj=25 C
FIG.2-TYPICAL FORWARD
CHARACTERISTICS
MBR10150CT - MBR10200CT
MBR1060CT