Test Report
No.: DGC141029016AE02 Date: November 03, 2014 Page 1 of 9
This document cannot be reproduced except in full, without prior written approval of ATC. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
Accurate Technology Co., Ltd.
Address: No.345, Baima Block, Guantai Road, Nancheng District, Dongguan, Guangdong, China
Tel: (+86-769) 23301666 Fax: (+86-769) 23301600 Email: dgcs@atc-lab.com Http://www.dgatc-lab.com
Applicant: DONGGUAN BETTER ELECTRONICS TECHNOLOGY CO., LTD.
Address: Room 601 of 16 Block, No.1 Headquarters Valley, Hisinchu Road, Songshan Lake High-tech
Industrial Development Zone, Dongguan City, Guangdong Province
Manufacturer: FoShan Wholesome Electronics Co., Ltd
Address: NO.17, WuFeng Industrial District, Zhangcha of FOSHAN City, GUANGDONG Province
Sample Name: Thermostat
Model No.: KST series, ATM series, KSD series
Date of Sample Received: October 29, 2014
Test period: October 29, 2014 to November 03, 2014
Test requested: In accordance with RoHS Directive 2011/65/EU.
Test method: With reference to IEC 62321-2008 Procedures for the Determination of Levels of
Regulated Substances in Electrotechnical Products, XRF scanning first test, then using
chemical test method to confirm.
Test result: Please refer to next page.
Conclusion: Based on the test results, the submitted sample(s) comply with the RoHS Directive
2011/65/EU.
Written by:
Checked by:
Approved by:
Test Report
No.: DGC141029016AE02 Date: November 03, 2014 Page 2 of 9
This document cannot be reproduced except in full, without prior written approval of ATC. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
Accurate Technology Co., Ltd.
Address: No.345, Baima Block, Guantai Road, Nancheng District, Dongguan, Guangdong, China
Tel: (+86-769) 23301666 Fax: (+86-769) 23301600 Email: dgcs@atc-lab.com Http://www.dgatc-lab.com
Test method:
Testing Item Pretreatment Method Measuring Instrument MDL
Lead (Pb) IEC 62321: section 8/9/10 ICP-OES 2mg/kg
Cadmium (Cd) IEC 62321: section 8/9/10 ICP-OES 2mg/kg
Mercury (Hg) IEC 62321: section 7 ICP-OES 2mg/kg
Chromium (Cr
6+
)
IEC 62321: Annex C
UV-Vis
2mg/kg
IEC 62321: Annex B ---
PBBs/PBDEs IEC 62321: Annex A GC-MS 5mg/kg