Test Report No.: DGC141029016AE01 Date: November 03, 2014 Page
1
of
19
This document cannot be reproduced except in full, without prior written approval of ATC. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
Accurate Technology Co., Ltd.
Address: No.345, Baima Block, Guantai Road, Nancheng District, Dongguan, Guangdong, China
Tel: (+86-769) 23301666 Fax: (+86-769) 23301600 Email: dgcs@atc-lab.com Http://www.dgatc-lab.com
Applicant: DONGGUAN BETTER ELECTRONICS TECHNOLOGY CO., LTD.
Address: Room 601 of 16 Block, No.1 Headquarters Valley, Hisinchu Road, Songshan Lake
High-tech Industrial Development Zone, Dongguan City, Guangdong Province
Manufacturer: FoShan Wholesome Electronics Co., Ltd
Address: NO.17, WuFeng Industrial District, Zhangcha of FOSHAN City, GUANGDONG Province
Sample Name: Thermostat
Model No.: KST series, ATM series, KSD series
Date of Sample Received: October 29, 2014
Test period: October 29, 2014 to November 03, 2014
Test requested: As specified by client, In accordance with REACH Directive EC No 1907/2006,
determine the one hundred and fifty-five (155) Substances of Very High
Concern (SVHC) which were published by European Chemicals Agency
(ECHA)content on submitted sample.
Test method: Please refer to next page.
Test result: Please refer to next page.
Conclusion: According to the specified scope and analytical technique, the concentration of one
hundred and fifty-five (155) Substances of Very High Concern (SVHC) are all lower
than 0.1%(W/W) on submitted sample.
Written by:
Checked by:
Approved by:
Test Report No.: DGC141029016AE01 Date: November 03, 2014 Page
2
of
19
This document cannot be reproduced except in full, without prior written approval of ATC. Any unauthorized alteration, forgery or falsification of the content or
appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the results shown in this test report
refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
Accurate Technology Co., Ltd.
Address: No.345, Baima Block, Guantai Road, Nancheng District, Dongguan, Guangdong, China
Tel: (+86-769) 23301666 Fax: (+86-769) 23301600 Email: dgcs@atc-lab.com Http://www.dgatc-lab.com
Test Results (Unit: %):
1. The first batch of SVHC:
Test Items EC No. CAS No.
Pretreatment
Method
Measuring
Instrument
MDL
Results
No.1
Anthracene 204-371-1 120-12-7 ZEK 01.4-08, GC-MS 0.0002 N.D.
4,4’-
Diaminodiphenylmethan
e
202-974-4 101-77-9
EN
14362-1:2003
GC-MS 0.003 N.D.
Dibutyl phthalate
(DBP)
201-557-4 84-74-2
US EPA
3540C:1996
GC-MS 0.003 N.D.
Benzyl butyl phthalate
(BBP)
201-622-7 85-68-7
US EPA
3540C:1996
GC-MS 0.003 N.D.
Bis
(2-ethyl(hexyl)phthalate)
(DEHP)
204-211-0 117-81-7
US EPA
3540C:1996
GC-MS 0.003 N.D.
5-tert-butyl-2,4,6-trinitro-
m-xylen
201-329-4 81-15-2
US EPA
3540C:1996
GC-MS 0.005 N.D.
Hexabromocyclododeca
ne
(HBCDD) and all major
diastereoisomers
identified
247-148-4
25637-99-4
3194-55-6
(134237-50-6
134237-51-7
134237-52-8)
US EPA
3540C:1996
GC-MS 0.005 N.D.
Short Chain Chlorinated
Paraffins
287-476-5 85535-84-8
US EPA
3540C:1996
GC-MS 0.01 N.D.
Bis(tributyltin)oxide ** 200-268-0 56-35-9
ISO17353:20
05
GC-MS 0.005 N.D.
Cobalt dichloride ** 231-589-4 7646-79-9
US EPA
3052:1996
BS EN
14582:2007
ICP-OES&IC 0.001 N.D.
Diarsenic pentaoxide ** 215-116-9 1303-28-2
US EPA
3052:1996
ICP-OES 0.001 N.D.
Diarsenic trioxide ** 215-481-4 1327-53-3
US EPA
3052:1996
ICP-OES 0.001 N.D.
Lead hydrogen arsenate
**
232-064-2 7784-40-9
US EPA
3052:1996
ICP-OES 0.001 N.D.
Triethyl arsenate ** 427-700-2 15606-95-8
US EPA
3052:1996
ICP-OES 0.001 N.D.
Sodium dichromate ** 234-190-3
7789-12-0&
10588-01-9
US EPA
3060A:1996
UV-Vis 0.0002 N.D.