© 2021 TELEDYNE RELAYS (800) 284-7007 • www.teledynedefenseelectronics.com Page 1
Series GRF121A/GRF121AR
SPDT Magnetic-Latching
DC-18GHz RF Relay
40Gbps
GRF121A\GRF121AR\062021
SERIES RELAY TYPE
GRF121A RF Magnetic-Latching, SPDT, Common Coil Negative, ungrounded contacts, Surface Mount Relay
GRF121AR RF Magnetic-Latching, SPDT, Common Coil Positive, ungrounded contacts, Surface Mount Relay
SURFACE MOUNT
HIGH REPEATABILITY
SPDT, BROADBAND 18 GHZ
40GBPS
MAGNETIC-LATCHING RF RELAY
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
Storage –55��C to +125°C
Operating –55°C to +85°C
Vibration
(Note 3)
10 g’s, 10 to 3000 Hz
Shock
(Note 3)
30 g’s,
6ms half sine
Enclosure Hermetically sealed
DESCRIPTION
The ultraminiature GRF121A /GRF121AR relay is a
Bidirectional, Open Contact SPDT Relay, designed
to provide a practical surface-mount switching solu-
tion with RF performance and repeatability to 16GHz.
The GRF121A/GRF121AR improves on Teledyne
Relays’ heritage of miniature RF relays by incorpo-
rating a precision transmission line structure in the
internal construction of the contact system. GRF121A
/GRF121AR relays feature a unique ground shield to
facilitate surface mounting and to extend the frequency
range when compared to through-hole solutions.
These relays are designed for use in RF attenuators,
RF switch matrices, high frequency spread
spectrum radios, ATE, and other applications that
require dependable high frequency signal delity
and performance. The magnetic-latching GRF121A /
GRF121AR is suitable for applications where power
budget is restricted. The relays can be operated with a
short duration pulse. After the contacts have trans-
ferred, no external holding power is required.
The GRF121A /GRF121AR features:
High Repeatability
Wide Bandwidth Performance
Metal Enclosure for EMI Shielding
High Isolation Between Control and Signal Paths
High Resistance to ESD
The unique construction features and manufacturing
techniques provide excellent robustness for
environmental extremes and overall reliability:
Minimum mass components and welded
construction provide maximum resistance to shock
and vibration
Advanced cleaning techniques provide maximum
assurance of internal cleanliness
Gold-plated precious metal alloy contacts ensure
reliable switching
Hermetic Seal
RoHS Compliant
Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2021 TELEDYNE RELAYS
Series GRF121A/GRF121AR
SPDT Magnetic-Latching
DC-18GHz RF Relay
40Gbps
GRF121A\GRF121AR\062021
GENERAL ELECTRICAL SPECIFICATIONS (@ 25°C)
Contact Arrangement 1 Form C (SPDT)
Rated Duty Continuous
Contact Load Rating Resistive: 0.25A @ 28Vdc
Contact Life Rating 3,000,000 cycles typical at low level
Coil Operating Power
GRF121-5: 410mW typical @ nominal rated voltage
GRF121-12: 290mW typical @ nominal rated voltage
Switching Time 7.0 msec. max. (2 msec operate time, 5 msec bounce time)
Minimum Operate Pulse 6.0 msec width at rated voltage
Insulation Resistance 1,000MΩ min. between mutually isolated terminals
Dielectric Strength 350 Vrms (60Hz) @ Atmospheric Pressure
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
BASE PART NUMBERS
GRF121/GRF121AR-5 GRF121/GRF121AR-12
Coil Voltage, Nominal (Vdc)
5.0 12.0
Coil Resistance (Ohms ±20%) 61 500
Pick-up Voltage, Max (Vdc) (General Note 5) 4.3 10.4
NOTES
1. Characteristics shown as “typical” are based on available data and are best estimates. No ongoing verification tests are performed.
2. Unless otherwise specified, parameters are initial values.
3. Relay contacts will exhibit no chatter in excess of 10 µsec or transfer in excess of 1 µsec.
4. Relay leads are gold plated with a typical thickness of 25-40 µin. Ground shield is gold plated with a typical thickness of 10-30µin.
5. Operate voltage at less than the specified minimum may result in unreliable operation.
6. Relay temperature during soldering shall not exceed 250°C, and reflow temperature shall not exceed 250°C, 3 passes, 1 minute each.
GRF121A - 12
Relay Series
Part Numbering System (Note 4)
Coil Voltage
5 = 5Vdc
12 = 12Vdc
GRF121A
GRF121AR