Product: OCTOPUS 8TX -EEC
Unmanged IP67 Switch, 8 ports, supply voltage 24 VDC, train approvals
Product Description
Unmanaged IP 65 / IP 67 switch in accordance with IEEE 802.3, store-and-forward-switching, Fast-Ethernet (10/100 MBit/s) ports, electrical Fast-Ethernet
(10/100 MBit/s) M12-ports
Technical Drawing
Technical Specifications
Product description
Type: OCTOPUS 8TX-EEC
Description:
The OCTOPUS switches are suited for outdoor applications with rough environmental conditions. Because of the branch typical approvals they can be used in transport applications
(E1), as well as in trains (EN 50155) and ships (GL).
Part Number: 942150001
Port type and quantity: 8 ports in total uplink ports: 10/100 BASE-TX, M12 "D"-coding, 4-pole 8 x 10/100 BASE-TX TP-cable, auto-crossing, auto-negotiation, auto-polarity.
More Interfaces
Power supply/signaling
contact:
1 x M12 5-pin connector, A coding, no signaling contact
USB interface: 1 x M12 5-pin socket, A coding
Network size - length of cable
Twisted pair (TP): 0-100 m
Network size - cascadibility
Line - / star topology: any
Power requirements
Operating Voltage: 12 / 24 / 36 VDC (9,6 .. 45 VDC)
Power consumption: 4.2 W
Power output in BTU
(IT)/h:
12.3
Redundancy functions: redundant power supply
Software
Diagnostics: LEDs (power, link status, data)
Configuration:
Switch: aging time, Qos 802.1p mapping, QoS DSCP mapping. Pro Port: port state, flow control, broadcast mode, multicast mode, jumbo frames,QoS trust mode, port-based priority,
auto-negociation, data rate, duplex mode, auto-crossing, MDI state
Ambient conditions
Operating temperature: -40-+70 °C
Note: Please note that some recommended accessory parts only support a temperature range from -25 ºC to +70 ºC and might limit the possible operating conditions for the entire system.
Storage/transport
temperature:
-40-+85 °C
Relative humidity (also
condensing):
5-100 %
Mechanical construction
Dimensions (WxHxD): 60 mm x 200 mm x 31 mm
Weight: 470 g
Mounting: Wall mounting
Protection class: IP65, IP67
Mechanical stability
IEC 60068-2-6 vibration: 1 mm, 2 Hz-13.2 Hz, 90 min. 0.7 g, 13.2 Hz-100 Hz, 90 min. 3.5 mm, 3 Hz-9 Hz, 10 cycles, 1 octave/min. 1 g, 9 Hz-150 Hz, 10 cycles, 1 octave/min
IEC 60068-2-27 shock: 15 g, 11 ms duration, 18 shocks
EMC interference immunity
EN 61000-4-2
electrostatic discharge
(ESD):
6 kV contact discharge, 8 kV air discharge
EN 61000-4-3
electromagnetic field:
20 V/m (80-3000 MHz)
EN 61000-4-4 fast
transients (burst):
2 kV power line, 4 kV data line
EN 61000-4-5 surge
voltage:
power line: 2 kV (line/earth), 1 kV (line/line), 2 kV data line
EN 61000-4-6 Conducted
Immunity:
3 V (10 kHz-150 kHz), 10 V (150 kHz-80 MHz)
EMC emitted immunity
EN 55032: EN 55032 Class A
FCC CFR47 Part 15: FCC 47CFR Part 15, Class A
Approvals
Basis Standard: CE, EAC, Australian Regulatory Compliance Mark (RCM)
Safety of industrial control
equipment:
cUL61010-2-201