cui.com
date 05/13/2021
page
1 of 6
SERIES: VOF-180 DESCRIPTION: AC-DC POWER SUPPLY
MODEL
output
voltage
output
current
output
power
1,2
ripple
and noise
3,4
eciency
(Vdc)
max
(A)
max
(W)
max
(mVp-p)
typ
(%)
VOF-180-12 12 15 180 240 88
VOF-180-15 15 12 180 300 88
VOF-180-24 24 7.5 180 240 90
VOF-180-30 30 6 180 300 90
VOF-180-48 48 3.75 180 480 92
VOF-180-58 58 3.10 180 580 92
Notes: 1. Maximum output power of 180 W with 13 CFM forced air cooling, and 120 W with natural convection cooling at 100 to 264 Vac.
2. Combined output power of main output and fan supply shall not exceed the max power rating.
3. Ripple is peak to peak with 20 MHz bandwidth and 10 µF tantalum capacitor in parallel with a 0.1 µF capacitor at rated line voltage and load ranges.
4. Output ripple can be more than 10% of the output voltage at -40°C.
5. All specications are measured at Ta=25°C, nominal input voltage, and rated output load unless otherwise specied.
FEATURES
• up to 180 W continuous power
• -40°C to 70°C operating temperature
• industry standard foot print 2” x 4”
• low profile 0.75”
• power factor correction
• 12 V/0.5 A fan output
• standby power <0.5 W
• efficiency up to 92%
• long life electrolytic capacitors
PART NUMBER KEY
Base Number
VOF-180 - XX - X
Output Voltage
Output Connections:
“blank” = screw type
1 = header type
Additional Resources: Product Page | 3D Model
cui.com
date 05/13/2021 page 2 of 6CUI Inc SERIES: VOF-180 DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 80 264 Vac
frequency 47 63 Hz
current
at 115 Vac, full load
at 230 Vac, full load
2.2
1.1
A
A
inrush current at 230 Vac, cold start 45 A
leakage current at 230 Vac 0.3 mA
power factor at full load 0.95
no load power consumption 0.5 W
input fuse 3.15 A/250 V time delay fuse (included)
OUTPUT
parameter conditions/description min typ max units
initial set point accuracy ±1 %
line regulation ±0.5 %
load regulation from 100% to 10% load ±1 %
start-up delay time 2 s
rise time at 115/230 Vac 55 ms
hold-up time at 115/230 Vac 10 ms
adjustability
1
built in trim pot ±3 %
switching frequency 50 300 kHz
transient response
25% step load change, at 0.1 A/µS slew rate, 50%
duty cycle, 50/60 Hz, max excursion 4%, recovery
time 5 ms
temperature coecient at 0~50°C ±0.05 %/°C
fan output
2
12 Vdc / 500 mA
Notes: 1. Adjustment potentiometer is located on the SMT side of the PCB.
2. Fan supply output voltage tolerance including set point accuracy, line and load regulation is ±10% and ripple and noise is less than 10%.
PROTECTIONS
parameter conditions/description min typ max units
over voltage protection hiccup, auto recovery 110 140 %
over current protection hiccup, auto recovery 110 %
short circuit protection hiccup, auto recovery
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage
input to output
input to ground
3,000
1,500
Vac
Vac
safety approvals
EN 60950-1, IEC 60950-1 (ed.2), UL 60950
(ed.2), CSA C22.2 No. 60950-1 (ed.2), Class 1
SELV complies with LVD directive
safety class class I
conducted emissions EN 55032 Class B
radiated emissions
EN 55032 Class B (to be controlled in end system with external
core (King core K5B RC 25 x 12 x 15-M in input cable (5 turns))
input current harmonics EN 61000-3-2, class D
voltage uctuation and icker EN 61000-3-3, pass
ESD immunity EN 61000-4-2, level 3, criterion A
Notes: 3. The power supply is considered a component which will be installed into nal equipment. The nal equipment still must be tested to meet the necessary EMC directives.
Additional Resources: Product Page | 3D Model