No. ES150309011CE007
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at
http://www.emtek.com.cn . Attention is drawn to the limitations of liability, indemnification and jurisdictional policies defined therein. The results shown in this test report
refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. This Test Report cannot be reproduced, except in full,
without prior written permission of the Company.
Page 1 of 27
UNI-TREND TECHNOLOGY (CHINA) LIMITED
NO. 6, GONGYEBEI 1ST ROAD, SONGSHAN LAKE NATIONAL HIGH-TECH INDUSTRIAL DEVELOPMENT
ZONE, DONGGUAN CITY,GUANGDONG PROVINCE, CHINA
(The Submitted Sample Said To Be)
Sample Name
:
UT300 series
Item/Style No.
:
UT300ABC.UT301ABC.UT302ABCD.UT303ABCD.UT305A.B.C
Sample Received Date
:
March 09, 2015
Testing Completed Date
:
March 20, 2015
Test Requested
:
1. As requested by client, to evaluate the compliance of the submitted sample with the
Directive 2011/65/EU of the European Parliament and of the Council of 8 June 2011 on
the restriction of the use of certain hazardous substances in electrical and electronic
equipment.
2. As requested by client, according to the specification from paragraph 10 of Directive
2011/65/EU, for taking into account Annexes XIV and XVII of the REACH Regulation (EC)
NO.1907/2006, to determine the contents of the regulated phthalate in the submitted
sample(DEHP,DBP,BBP).
3. As requested by client, according to the specification from paragraph 10 of Directive
2011/65/EU, for taking into account Annexes XIV and XVII of the REACH Regulation (EC)
NO.1907/2006, to determine the 1,2,5,6,9,10-Hexabromocyclododecane(HBCDD)
contents in the submitted sample.
Test Method
:
A. Review was performed for the sample and the related Bill of Material submitted by the
Applicant.
B. To refer to the standard IEC 62321:2008 Ed.1
a) Screening by XRF Spectroscopy.
b) Wet chemical test
i) Determination of Lead, Cadmium and Mercury by ICP-OES / AAS.
ii) Determination of Hexavalent Chromium by UV-VIS.
iii) Determination of PBBs and PBDEs by GC/MS.
C. To refer to the EN14372:2004(clause 6.3.2) & US EPA3540C:1996, the analysis was
performed by Gas Chromatography Mass Spectrometry (GC-MS).
Test Results
:
Please refer to next page (s).
Test Report
No. ES150309011CE007
This Test Report is issued by the Company subject to its General Conditions of Service printed overleaf or available on request and accessible at
http://www.emtek.com.cn . Attention is drawn to the limitations of liability, indemnification and jurisdictional policies defined therein. The results shown in this test report
refer only to the sample(s) tested unless otherwise stated and the sample(s) are retained for 30 days only. This Test Report cannot be reproduced, except in full,
without prior written permission of the Company.
Page 2 of 27
Conclusion:
Basing on the test results obtained from the homogenous materials, the submitted sample COMPLIES with
the requirements stated in the Annex II of RoHS Directive 2011/65/EU.
Signed for and on behalf of
Shenzhen EMTEK Co., Ltd .
-----------------------------------
Manager
March 20, 2015