JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone: +49 661 6003-0
Fax: +49 661 6003-607
Email: mail@jumo.net
Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2DY, UK
Phone: +44 1279 63 55 33
Fax: +44 1279 62 50 29
Email: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: +1 315 437 5866
Fax: +1 315 437 5860
Email: info.us@jumo.net
Internet: www.jumousa.com
Page 1/11
(1)
(3)
Data Sheet 201005
V1.01/EN/00433884
JUMO ecoLine / JUMO BlackLine
pH and redox combination electrodes
in glass or plastic shaft versions
201005 series - pH electrodes
201010 series - redox electrodes
Brief description
The electrodes of the JUMO ecoLine and JUMO BlackLine series are high-quality measurement
sensors with a good price/performance ratio.
Active pH component: The JUMO ecoLine and JUMO BlackLine electrodes are equipped with
low-resistance JUMO UW glass. This guarantees fast and safe measurement results.
Active redox component: A sturdy platinum tip provides safe measurements and makes the
sensor easy to clean.
Reference system: Acrylamide-free JUMO gel is used in the glass and PEI plastic shaft versions.
This highly viscous KCl solution is ideal for measurement in general, aqueous media. The
electrolyte can be equipped with an optional "salt reserve" to increase the service life when
measurements take place in media with fewer ions or at high flow rates. A polymerized solid KCl
electrolyte is used in the JUMO BlackLine version. The JUMO cartridge-style conduction
system has proved its worth over the years and is the reference system used here. This keeps
the electrolyte free of silver ions throughout the life of the sensor, making it less susceptible to
electrode poisons.
In the "glass shaft" (1) version, JUMO ecoLine electrodes have a ceramic diaphragm. A glass
fiber diaphragm is provided for the plastic shaft version made from transparent PEI (2). A push-
on protection basket guards the sensor when it is used with hand-held meters. The JUMO
BlackLine (3) has a high-quality ceramic diaphragm. The shaft is made from black PPO and has
an integrated protection basket.
The option is available to have the electrodes delivered in a storage container (holder). This is
recommended if sensors are only used sporadically, to refresh them after lengthy periods of
intensive use, or if they are stored for extended periods of time.
OEM versions of all sensors can be supplied to order.
Special versions are available on request.
Areas of application
Drinking water monitoring and treatment
Swimming pools
Aquariums (also marine aquariums)
Greenhouse systems
Lightly polluted service water, process water and wastewater
Rainwater, pond water and surface water
•Hand-held meters
Not recommended for:
Electroplating water treatment
Industrial process water and wastewater
•Ultra-pure water
Therapy pools
Biotechnology, sterilization processes
For other applications, refer to the data sheets
for JUMO tecLine or JUMO labLine pH and redox electrodes!
Provisional
V
(2)
(1) Glass shaft version
(2) Version with plastic shaft
and push-on protection basket
(3) JUMO BlackLine
version with plastic shaft
and fixed protection basket
20100500T10Z001K000
V1.01/EN/00433884
Page 2/11Data Sheet 201005
JUMO GmbH & Co. KG
Delivery address: Mackenrodtstraße 14
36039 Fulda, Germany
Postal address:
36035 Fulda, Germany
Phone: +49 661 6003-0
Fax: +49 661 6003-607
Email: mail@jumo.net
Internet: www.jumo.net
JUMO Instrument Co. Ltd.
JUMO House
Temple Bank, Riverway
Harlow, Essex CM 20 2DY, UK
Phone: +44 1279 63 55 33
Fax: +44 1279 62 50 29
Email: sales@jumo.co.uk
Internet: www.jumo.co.uk
JUMO Process Control, Inc.
6733 Myers Road
East Syracuse, NY 13057, USA
Phone: +1 315 437 5866
Fax: +1 315 437 5860
Email: info.us@jumo.net
Internet: www.jumousa.com
20100500T10Z001K000
Technical data
Extra codes
Further pH and redox electrodes can be found in the following data sheets:
Glass shaft version
(Figure 1, page 1/8)
Version with plastic shaft and
push-on protection basket
(Figure 2, page 1/8)
JUMO BlackLine
Version with plastic shaft and
fixed protection basket
(Figure 3, page 1/8)
Shaft material glass PEI
a
a
PEI = polyetherimide.
PPO
b
b
PPO = polyphenylene ether.
Diaphragm ceramic glass filament ceramic
Conduction system plastic cartridge
Temperature range 0 to 60 °C
Pressure range
c
c
The pressure figures relate to stable conditions at the installation location: severe pressure surges and fluctuations should be avoided.
0to6bar
Fitting length 120 mm
Electrode head plug cap
plug cap with fixed cable
Pg13.5 screw cap
Pg13.5 screw cap with fixed cable
The connecting cable of versions with a fixed cable has anti-kink protection.
Versions with a fixed cable have IP68 enclosure protection
Active pH component UW glass
(pH 0 to 12, briefly pH 14)
Active redox component platinum tip (±2000 mV)
Electrolyte gel (highly viscous KCl solution) solid electrolyte
Recommended minimum conduc-
tivity of the medium
without salt reserve:100 µS/cm without salt reserve:150 µS/cm without salt reserve:100 µS/cm
with salt reserve:50 µS/cm with salt reserve:100 µS/cm with salt reserve:50 µS/cm
KCl reservoir (holder), extra code 052 Salt reserve, extra code 837
The foot of the KCl reservoir can
also be used as a mounting
wrench for pH and redox
electrodes with a Pg13.5 thread.
The indentations in the
(detachable) foot of the reservoir
fit the hexagon flats of the
electrode head.
When storing the electrodes, the
reservoir must be filled with KCl
(not with buffer solution
or similar).
The option is available to equip the
electrode with a salt reserve, in the
form of four salt rings (see
illustration).
This is recommended when using
the electrode in media with fewer
ions or at high flow rates.
The salt reserve helps to increase
the service life of the electrode.
The rings are not a manufacturing
defect (crystallization).
Data sheet 201020 – JUMO tecLine pH/Rd combination electrodes Data sheet 201030 – JUMO laboratory pH combination electrodes
Data sheet 201050 – JUMO ISFET pH combination electrode Data sheet 201081 – JUMO glass pH electrodes
Data sheet 201082 – JUMO single/twin redox electrodes Data sheet 201083 – JUMO reference electrode
Data sheet 201085 – JUMO compensation thermometers
Salt reserve