Industry-specific Ethernet Switches
Specifications
Introduction
TN-5508/5516 Series
EN 50155 8/16-port managed Ethernet switches
The ToughNet TN-5508/5516 series M12 managed Ethernet switches
are designed for industrial applications in harsh environments.
The TN series switches use M12 and other circular connectors to
ensure tight, robust connections, and guarantee reliable operation
against environmental disturbances, such as vibration and shock.
The TN-5500-LV-MV switches provide the wide power input range of
12/24/36/48/72/96/110 VDC that allows you to the same type of power
source at different sites around the globe. In addition, the 12/24/36/48
VDC, 72/96/110 VDC, or 110/220 VDC/VAC dual, isolated redundant
power supply increases the reliability of your communications and
saves on cabling/wiring costs. The TN-5508/5516 switches provide up
to 8 or 16 Fast Ethernet M12 ports. Models with an extended operating
temperature range of -40 to 75°C are also available. The TN-5500
series Ethernet switches are compliant with the essential sections of EN
50155, covering operating temperature, power input voltage, surge, ESD
and vibration, making the switches suitable for a variety of industrial
applications.
• Three rotary switches for setting the last 3 digits of the IP address
makes maintenance even easier
• IPv6 Ready logo awarded (IPv6 Logo Committee certified)
• Leading EN50155-compliant industrial Ethernet switches for rolling
stock applications
• DHCP Option 82 for IP address assignment with different policies
• Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250
switches), and RSTP/STP for network redundancy
• IGMP snooping and GMRP for filtering multicast traffic
• Port-based VLAN, IEEE 802.1Q VLAN, and GVRP to ease network
planning
• QoS (IEEE 802.1p/1Q and TOS/DiffServ) to increase determinism
• IEEE 802.3ad, LACP for optimum bandwidth utilization
• SNMPv3, IEEE 802.1X, HTTPS, and SSH to enhance network
security
• SNMPv1/v2c/v3 for different levels of network management
• RMON for efficient network monitoring and proactive capability
• Bandwidth management prevents unpredictable network status
• Lock port allows access by only authorized MAC addresses
• Port mirroring for online debugging
• Automatic warning by exception through email, relay output
• Line-swap fast recovery
• Automatic recovery of connected device’s IP addresses
• LLDP for automatic topology discovery in network management
software
• Configurable by web browser, Telnet/serial console, and Windows
utility
• Panel mounting or DIN-Rail mounting installation capability
Features and Benefits
Wide power input range from 12 to 110 VDC (LV-MV models)
Isolated redundant power inputs with universal 12/24/36/48 VDC,
72/96/110 VDC, or 110/220 VDC/VAC power supply range
Compliant with essential sections of EN 50155
-40 to 7C operating temperature range (T models)
Turbo Ring and Turbo Chain (recovery time < 20 ms @ 250
switches), and RSTP/STP for network redundancy
Technology
Standards:
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3ab for 1000BaseT(X)
IEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q for VLAN Tagging
IEEE 802.1p for Class of Service
IEEE 802.1X for Authentication
IEEE 802.3ad for Port Trunk with LACP
Protocols: IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3, DHCP Server/
Client, DHCP Option 66/67/82, BootP, TFTP, SNTP, SMTP, RARP,
RMON, HTTP, HTTPS, Telnet, SSH, Syslog, SNMP Inform, LLDP, IEEE
1588 PTP, IPv6, NTP Server/Client
MIB: MIB-II, Ethernet-like MIB, P-BRIDGE MIB, Q-BRIDGE MIB, Bridge
MIB, RSTP MIB, RMON MIB Group 1, 2, 3, 9
Flow Control: IEEE802.3x flow control, back pressure flow control
Switch Properties
Priority Queues: 4
Max. Number of Available VLANs: 64
VLAN ID Range: VID 1 to 4094
IGMP Groups: 256
2
www.moxa.com
info@moxa.com
Industry-specific Ethernet Switches
Dimensions
Unit: mm (inch)
Front View
Front View
Rear View
Rear View
DIN-Rail
Mounting Kit
DIN-Rail
Mounting Kit
Top & Bottom Views
Top & Bottom Views
TN-5508 Series
TN-5516 Series
Side View (including
DIN-Rail Mounting Kit)
Side View (including
DIN-Rail Mounting Kit)
Interface
Fast Ethernet: Front cabling, M12 connector, 10/100BaseT(X) auto
negotiation speed, F/H duplex mode, and auto MDI/MDI-X connection
Console Port: M12 A-coding 5-pin male connector
System LED Indicators: PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/
TAIL
Port LED Indicators: 10/100M
Alarm Contact: 2 relay outputs in one M12 A-coding 5-pin male
connector with current carrying capacity of 3 A @ 30 VDC
Rotary Switches: For setting the last 3 digits of the IP address
Power Requirements
Input Voltage:
•LV:12/24/36/48VDC(8.4to60VDC)
•MV:72/96/110VDC(50.4to137.5VDC)
•HV:110/220VDC/VAC(88to300VDC,85to264VAC)
Note: Compliant with EN 50155 on 24/48/72/96/110 VDC
Input Current:
•TN-5508Series:
0.234 A @ 24 VDC, 0.104 A @ 72 VDC,
0.072 A @ 110 VDC, 0.18 A @ 110 VAC,
0.12 A @ 220 VAC
•TN-5516Series:
0.338 A @ 24 VDC, 0.133 A @ 72 VDC,
0.089 A @ 110 VDC, 0.270 A @ 110 VAC,
0.170 A @ 220 VAC
Overload Current Protection: Present
Connection: M23 connector
Reverse Polarity Protection: Present
Physical Characteristics
Housing: Metal, IP54 protection (optional protective caps available for
unused ports)
Dimensions:
TN-5508 Series: 185 x 175.8 x 69.8 mm (7.28 x 6.92 x 2.75 in)
TN-5516 Series: 250 x 175.8 x 69.8 mm (9.84 x 6.92 x 2.75 in)
Weight:
TN-5508 Series: 1650 g
TN-5516 Series: 2500 g
Installation: Panel mounting, DIN-Rail mounting (with optional kit)
Environmental Limits
Operating Temperature:
Standard Models: -25 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Altitude: Up to 2000 m
Note: Please contact Moxa if you require products guaranteed to function at
higher altitudes.
Standards and Certifications
Safety: UL 508 (Pending)
EMI: FCC Part 15 Subpart B Class A, EN 55022 Class A
EMS:
EN 61000-4-2 (ESD) Level 3,
EN 61000-4-3 (RS) exceeds Level 3,
EN 61000-4-4 (EFT) Level 3,
EN 61000-4-5 (Surge) Level 3,
EN 61000-4-6 (CS) Level 3,
EN 61000-4-8,
EN 61000-4-11
Rail Traffic: (for panel mounting installations)
EN 50155, EN 50121-4
Shock: IEC 61373
Freefall: IEC 60068-2-32
Vibration: IEC 61373
Note: Please check Moxa’s website for the most up-to-date certification status.
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty
8
Ø8
Ø4.50
155.0 (6.1)
170.0 (6.7)
67.7 (2.7)
53.2 (2.1)
120.0 (4.7)
120.0 (4.7)
170.0 (6.7)
185.0 (7.3)
127.0 (5.0)
37.0 (1.5) 37.0 (1.5)
69.8 (2.7) 63.2 (2.5)
175.8 (6.9)
8
Ø8
Ø4.50
235.0 (9.3)
67.7 (2.7)
69.8 (2.7)
62.7 (2.5)
52.7
(2.1)
250.0 (9.8)
177.0 (7.0)
37.0 (1.5) 37.0 (1.5)
170.0 (6.7)
175.8 (6.9)
120.0 (4.7)
120.0 (4.7)
220.0 (8.7)