www.hygroup.com.tw
Features MBR
Low forward voltage drop
Electrically isolated base -2000 Volts RoHS
COMPLIANT
Materials used carries U/L recognition
Mechanical Data
Polarity: Symbol Marked on body
Mounting position: Any
Applications
General purpose use in AC/DC bridge full wave rectification,
for power supply, industrial automation applications, etc.
Maximum Ratings and Electrical Characteristics
Rating at 25 ambient temperature unless otherwise specified.
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
MBR MBR MBR MBR MBR MBR MBR
10005 1001 1002 1004 1006 1008 1010
Maximum Repetitive Peak Reverse Voltage VRRM 50 100 200 400 600 800 1000 V
Maximum RMS Voltage VRMS 35 70 140 280 420 560 700 V
Maximum Average Forward Rectified Current @TC=55
I(AV) A
Peak Forward Surge Current, 8.3mS Single Half Sine-Wave,
Superimposed on Rated Load (JEDEC Method)
I
2
t Rating for Fusing (t<8.3mS) I
2
t A
2
s
Peak Forward Voltage per Diode at 5A DC
VF V
Maximum DC Reverse Current at Rated
DC Blocking Voltage per Diode @TJ=25
Operating Junction Temperature Range TJ
Storage Temperature Range
TSTG
MBR10*-S/B-00-00
Rev. 9, 22-Apr-2019
MBR10005 THRU MBR1010
Reverse Voltage - 50 to 1000 Volts
Forward Current - 10 Amperes
High surge forward current capability
Package Outline Dimensions in Inches (Millimeters)
Pb
Silicon Bridge Rectifiers
Characteristics
Symbol
IFSM
IR
Unit
A
μA
240
10
10
240
1.1
-55 to +150
-55 to +150
MBR10005 THRU MBR1010
Case Temperature ()
0
2
4
6
8
10
0 50 100 150
Fig. 1 - Forward Current Derating Curve
Average Forward Current (A)
0.1
1
10
0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6
TJ=25
°
C
TJ=75
°
C
TJ=100
°
C
TJ=125
°
C
Pulse Width 300uS
2%Duty Cycle
Fig. 4 - Typical Forward Characteristics
Instantaneous Forward Current (A)
Instantaneous Forward Voltage (V)
Fig. 2 - Maximum Non-Repetitive Surge Current
Number of Cycles at 60Hz
Peak Forward Surge Current (A)
0
50
100
150
200
250
300
1 10 100
8.3mS Single Half-Sine-Wave
(JEDEC METOD)
Instantaneous Reverse Current (uA)
Fig. 3 - Typical Reverse Characteristics
0.1
1
10
100
1000
20 40 60 80 100
TJ=25
°
C
TJ=75
°
C
TJ=100
°
C
TJ=125°C