PREMO (P/N) Description
SEA series catalogue
H
-
Field Magnetic Strength SEA series catalogue
References Date Edition Page
SEA-B-0345J/ SEA-B-0500J/SEA-B-0734J 27/11/2019 1.0
1
/
© PREMO S.L.U. All rights reserved. Reproduction or distribution of contents not allowed without prior written authorization.
https://www.grupopremo.com
H-Field Magnetic Strength
SEA series catalogue
PREMO (P/N) Description
SEA series catalogue
H
-
Field Magnetic Strength SEA series catalogue
References Date Edition Page
SEA-B-0345J/ SEA-B-0500J/SEA-B-0734J 27/11/2019 1.0
2
/
3
© PREMO S.L.U. All rights reserved. Reproduction or distribution of contents not allowed without prior written authorization.
https://www.grupopremo.com
1.
H-Field Magnetic Strength:
1.1
Procedure
Magnetic field probe measures in load Ipp to different distances (meters)
Receiving the signal from the probe field with the spectrum analyzer.
1.2 Setup
7.3 Orientation loop-antenna Vs Premo Antenna
The sample (antenna under test), the current flowing through it and the EM-field at X meters measured with a loop
antenna
(60cm) are obtained at resonant frequency. Note: Ipp is the current peak to peak measured with the oscilloscope.