Note: Due to continuous process improvement, specications are subject to change without notice. This document is cleared for public release.
Wilcoxon Sensing Technologies
8435 Progress Drive
Frederick, MD 21701
USA
Tel: +1 (301) 330-8811
Fax: +1 (301) 330-8873
info@wilcoxon.com
An Amphenol Company
buy.wilcoxon.com
www.wilcoxon.com
1
Key features
NEMA 4X, IP65 front panel
4-20 mA, ±10V, TC & RTD
eld-selectable inputs
Options for 2 relays,
isolated 4-20 mA output,
and 24 VDC transmitter
power supplies
Includes PC-based
programming and
monitoring software
External contacts for
remote button operation
Certications
PCD100 series
Process and temperature meters
The PCD100 digital panel meters are one of the most versatile on the market, and
are used in a wide variety of process and temperature applications. The PCD100
can be eld programmed to accept common process voltage (1-5V, ± 10V) and
current (0-20 mA, 4-20 mA) inputs, 100 Ω RTDs, and the four most common
thermocouples. One of the PCD100’s most useful features is its ability to provide 24
VDC to power the transmitters 4-20 mA signal. There are two power options: 85-
265 VAC or 12-36 VDC. The meter can be programmed via front panel or remotely.
99388 Rev.A 08/20
Ordering information
85-265 VAC 12-36 VDC Options installed
PCD100-265-B-N-0 PCD100-24-B-N-0 none
PCD100-265-B-N-200 24 VDC transmitter supply
PCD100-265-B-2R-0 PCD100-24-B-2R-0 2 relays
PCD100-265-B-2R-200
2 relays + 24 VDC transmitter
supply
PCD100-265-B-420-0 PCD100-24-B-420-0 4-20 mA output
PCD100-265-B-420-200
4-20 mA output + 24 VDC
transmitter supply
PCD100-265-B-420-240
4-20 mA output + dual 24 VDC
transmitter supplies
PCD100-24-B-2R420-0 2 relays + 4-20 mA output
PCD100-265-B-2R420-200
2 relays + 4-20 mA output + 24
VDC transmitter supply
The display is four full digits, meaning it can
display numbers up to 9999, an advantage
over most digital panel meters. The PCD100
can display type K thermocouples to 2300°F
and 4-20 mA signals up to 9,999.
The meter is supplied with two alarm points
that include front panel red LEDs to indicate
alarm conditions, making it particularly
useful for alarm applications that require
visual-only indication.
Front Panel NEMA 4X, IP65 Rated
PCD100 series
Note: Due to continuous process improvement, specications are subject to change without notice. This document is cleared for public release.
Wilcoxon Sensing Technologies
8435 Progress Drive
Frederick, MD 21701
USA
Tel: +1 (301) 330-8811
Fax: +1 (301) 330-8873
info@wilcoxon.com
An Amphenol Company
buy.wilcoxon.com
www.wilcoxon.com
2
PCD100 series
Process and temperature meters
SPECIFICATIONS
GENERAL
Display 1.2” (30.5 mm) height, 4 digits, red LED
Display intensity Eight levels, user-selectable
Front panel NEMA 4X, IP65 (panel gasket provided)
Programming methods Four front panel buttons, cloning with Copy feature, PC with MeterView software, Modbus registers
Power options
85-265 VAC, 50/60 Hz;
90-265 VDC, 20 W max or 12-36 VDC;
12-24 VAC, 6 W max
Required fuse UL recognized, 5 A max, slow-blow; up to 6 meters may share one fuse
Isolation
4 kV input/output-to-power line;
500 V input-to-output or output to 24 VDC supplies;
-2R420 models only: 100 V output-to-24 VDC supply
Temperature range
Operating: -40° to 65°C
Storage: -40° to 85°C
Relative humidity 0 to 90% non-condensing
Connections
Power & signal: removable screw terminal blocks accept 12 to 22 AWG
Serial: RJ11 header, standard on all meters
Enclosure 1/8 DIN, high impact plastic, 94V-0, color: gray
Weight 269 grams (9.5 oz) (including options)
DIMENSIONS
Side view
2.45”
[62.2 mm]
1.76” [44.7 mm]
0.59”
[15.0 mm]
3.20” [81.3 mm]
3.60” [91.4 mm]
Top view
2.50”
[63.5 mm]
4.68” [118.9 mm]
3.61”
[91.7 mm]
99388 Rev.A 08/20