Rev. A, October 2020
Description
Features
Package
TO-247-4L
Typical applications
750V-58mW SiC FET
w Low gate charge: Q
G
= 37.8nC
w PV inverters
w EV charging
w Switch mode power supplies
The UJ4C075060K4S is a 750V, 58mW G4 SiC FET. It is based on a
unique ‘cascodecircuit configuration, in which a normally-on SiC JFET
is co-packaged with a Si MOSFET to produce a normally-off SiC FET
device. The device’s standard gate-drive characteristics allows for a
true drop-in replacement” to Si IGBTs, Si FETs, SiC MOSFETs or Si
superjunction devices. Available in the TO-247-4L package, this
device exhibits ultra-low gate charge and exceptional reverse
recovery characteristics, making it ideal for switching inductive loads
and any application requiring standard gate drive.
w On-resistance R
DS(on)
: 58mW (typ)
w Operating temperature: 175°C (max)
w Excellent reverse recovery: Q
rr
= 52nC
w Low body diode V
FSD
: 1.31V
Part Number
w Low intrinsic capacitance
w Threshold voltage V
G(th)
: 4.8V (typ) allowing 0 to 15V drive
Marking
UJ4C075060K4S
UJ4C075060K4S
w ESD protected, HBM class 2
w TO-247-4L package for faster switching, clean gate waveforms
w Power factor correction modules
w Motor drives
w Induction heating
DATASHEET
UJ4C075060K4S
CASE
D (1)
S (2)
G (4)
KS (3)
3
CASE
1
2
4
Datasheet: UJ4C075060K4S Rev. A, October 2020 1
Maximum Ratings
Symbol Value Units
V
DS
750 V
V
GS
-20 to +20 V
28 A
20.6 A
I
DM
62 A
E
AS
24.3 mJ
P
tot
155 W
T
J,max
175 °C
T
J
, T
STG
-55 to 175 °C
T
L
250 °C
1. Limited by T
J,max
2. Pulse width t
p
limited by T
J,max
3. Starting T
J
= 25°C
Thermal Characteristics
Min Typ Max
R
qJC
0.75 0.97 °C/W
Gate-source voltage
DC
Max. lead temperature for soldering,
1/8” from case for 5 seconds
Power dissipation
T
C
= 25°C
Maximum junction temperature
Operating and storage temperature
T
C
= 25°C
Pulsed drain current
2
T
C
= 25°C
Single pulsed avalanche energy
3
L=15mH, I
AS
=1.8A
I
D
T
C
= 100°C
Continuous drain current
1
Units
Parameter
Symbol
Test Conditions
Value
Thermal resistance, junction-to-case
Parameter
Test Conditions
Drain-source voltage
Datasheet: UJ4C075060K4S Rev. A, October 2020 2