Keysight Technologies U5855A TrueIR Thermal Imager
Items
U5855A
FLIR E40 Fluke Ti125 Testo 875i -1
Basic imaging system
Detector resolution/iFOV (mrad) 160 x 120 (19,200 px)/3.1 160 x 120 (19,200 px)/2.72 120 x 160 (19,200 px)/3.39 160 x 120 (19,200 px)/3.3
Fine resolution (IR)/iFOV (mrad) 320 x 240 (76,800 px)/2.1 N/A N/A 320 x 240 (76,800 px)/2.1
Range/sensitivity (NETD) @
temp (°C)
20 to 350/0.07 @ 30 20 to 650/0.07 @ 30 20 to 350/0.1 @ 30 20 to 350/0.05 @ 30
E40bx: 20 to 120/0.045 @ 30
1
TiR125: 20 to 150/0.08 @ 30
1
Focusing mechanism Manual Manual Manual Manual
Minimum focus distance 10 cm
2
20 cm 15 cm 18 cm
Visible camera 3.1 MP 3.1 MP 2 MP Included
FOV (degree)/lens system 28 x 21/xed 25 x 19/std 25°; Opt: 15° tele and 45°
wide
22.5 x 31/xed 32 x 23/Opt: 9° tele
Image modes IR, visible, PIP, Fusion/blend IR, visible, PIP, fusion, MSX IR, visible, PIP, fusion, autoblend IR, visible, visual and IR image
blending (TwinPix)
Measurement and tools
Torch/laser Torch/laser Torch/laser Torch/laser Laser
Digital zoom 4x 2x N/A N/A
Color templates/scale 5 standard 6 standard 8 standard, 3 ultra contrast 9 standard
Isotherm/color alarm Color alarm Isotherm Color alarm N/A
Measurements Center, 3 spots, 3 boxes (with statis-
tic), delta, max/min markers
3 spot, 3 box, delta Center box, 3 spots, max/min mark-
ers
2 spots, max/min markers
Annotations/tagging Note tag, + 3 photos tags Text, voice 3 photo note, voice (60 sec) None
General specications
Records Image, image logging Images, MPEG4 video Images, MPEG4 video Images
IO/wireless USB, video out (RCA) USB, video out, WiFi/Bluetooth
®
,
touch screen
USB USB
Software FREE download Included Included Included
Weight 746 gm 825 gm 726 gm 907 gm
Sample IR image
1. FLIR and Fluke have separate models for: Maintenance use (low NETD, higher range) and building diagnostics (high NETD, lower range)
2. 10 to 50 cm at half accuracy and 50 cm for full accuracy
This information is subject to change without notice.
© Keysight Technologies, 2017
Published in USA, December 1, 2017
www.keysight.com
Keysight | The U55855A TrueIR Thermal Imager – Flyer