Find us at www.keysight.com Page 2
Important note
When the N5194A UXG vector adapter is used with the N5193A UXG agile signal generator, the
N5193A must have options CC1 and SS4 installed.
Step 1. Select frequency range (required option; frequency range not upgradeable)
Frequency range from 10 MHz to 20 GHz
Not compatible with Option 540
Includes standard adapter 3.5mm(f) to 3.5 mm(f)
Frequency range from 10 MHz to 40 GHz
Not compatible with Option 520
Includes standard adapters 2.4mm(f) to 2.4 mm(f) and
2.4mm(f) to 2.9 mm(f)
Step 2. Choose frequency resolution
Frequency resolution 10 kHz
Frequency resolution 0.001 Hz
The FR1 option is not required for fine frequency resolution if
the N5193A is being used as a local oscillator for an N5194A.
Step 3. Choose switching speed options
N5193A: List update rate 100 µs
Update rate 1 µs; not compatible with Option SS4
Update rate 180 ns, not compatible with Option SS1
Step 4. Choose amplitude range
Amplitude range +10 to -10 dBm
Mechanical and solid-state attenuator
80 dB agile range and 120 dB overall range