Installation and Maintenance Instructions
COMMON SPECIFICATIONS FOR ALL UNIITS:
Calibration Reference Conditions:
Ambient Temperature: -40 TO 176°F (-40 to 80°C)
Relative Humidity: 40 to 60%
Barometric Pressure: 29.92 in. Hg.
Performance Characteristics:
Accuracy (L,H&R): ± 0.25% FSO at 75°F (BFSL of L/H/R effects at 75°F)
±0.1% FSO at 75°F (Optional)
±0.5% for Vacuum only [-23] typical
Long Term Stability: Will repeat within ± 0.2% FSO of original
calibration curve for 3 year
Proof Pressure: 2X range for up to 7500 psi models;
1.5X range for 7500 30000 psi models.
Vibration: 2000 Hz at 15 g’s peak, MIL-STD 202,
METHOD 204, COND. B
Shock: 50 g’s, 11 ms, MIL-STD 202, METHOD 213, Cond. G.
Wetted Material: 316L Stainless Steel (up to 10k psi)
17-4 PH Stainless Steel (>15k psi)
Pressure Cavity Volume: 0.08 inches³ maximum approx.
CALIBRATION:
All models are tested to meet or exceed the published specifications. The
calibration and testing were done using instrumentation and standards traceable
to the National Institute of Standards and Technology (NIST). Also tested in
accordance with MIL-STD-45662A.
Approvals:
North America:
UL and c-UL Listed Pressure Transmitter
For use in Hazardous Locations
Class I, Div. I, Groups A, B, C & D
Class II, Div. I, Groups E, F & G.
450X Series
Barksdale Intelligent Transmitter
Model Series: H455X(4 20 mA), 455X (4-20mA) & 452X (1-5 VDC):
Excitation Voltage: 9 to 30 VDC Or 11/14-30 VDC
Analog Output: 4 to 20 mA (H455X & 455X)
1 5 VDC (452X)
Zero Balance: ±1% FSO at 75°F (24°C)
Protection: Reverse polarity protected
Loop Resistance: See loop resistance chart on back page
Temperature Range: Compensated: 0 to +165°F (-18 to +74°C)
Operating: -40 to +176°F (-40 to +80°C)
Media: -40 to +176°F (-40 to +80°C)
Temperature Error: ±1% per 100°F
Weight: 16 Oz (453 grams)
Wiring: Red = +Excitation
Black = -Excitation
Green (Drain) = Case/Earth Ground
White = Voltage Output only
Span Adjustment (Turn Down): 10:1 (With HART option only)
Span Accuracy: ±1% FS AT 75°F (24°C).
Consult Sales Drawing & EN/IEC 61000-4 for appropriate
Electromagnetic Compatibility (EMC) requirements.
II 2 G D
Ex db IIC T5 Gb
Ex tb IIIC T81°C Db IP66 & IP67
-40°C < Tamb < +80°C
DEMKO 18 ATEX 2084
IECEx UL 18.0090
For Canadian installations, a second conduit seal is not required for all pressure ranges up to 10,000 PSI which are Single Seal compliant to ANSI / ISA 12.27.01
2011 Standard. Other higher pressure range models require an appropriate Ex Type Flameproof (“d” protection) approved conduit seal and/or stopping box
with minimum temperature rating of -4to +80 °C. All system design considerations and installation guidelines must be in accordance with the national and
local electrical safety codes per CEC 22.1 / NFPA 70 Standards.
W
A
R N I N G ! READ BEFORE INSTALLATION
Fluid hammer and surges can destroy any pressure transmitter and must always be avoided. A pressure snubber should be installed to eliminate the
damaging hammer effects. Fluid hammer occurs when a liquid flow is suddenly stopped, as with quick closing solenoid valves. Surges occur when flow is
suddenly begun, as when a pump is turned on at full power or a valve is quickly opened.
Barksdale pressure transmitters having a pressure range 500 psi and higher have a built in pressure surge protection in the input port. The design is such that an
orifice is made an integral part of the pressure port. Designed with the upstream side of the orifice as a sharp corner, it acts as a very effective protection. Other
orifice devices can be installed upstream of the pressure transmitter in the piping system for extra protection where the system engineer requires it.
Liquid surges are particularly damaging to pressure transmitters if the pipe is originally empty. To avoid damaging surges, fluid lines should remain full (if
possible), pumps should be brought up to power slowly, and valves opened slowly. To avoid damage from both fluid hammer and surges, a surge chamber
should be installed, and a pressure snubber should be installed on every transmitter.
Symptoms of fluid hammer and surges damaging effects:
1. Pressure transmitter exhibits an output at zero pressure (large zero offset). If zero offset is less than 10% FS, user can usually re-zero meter,
install proper snubber and c o ntin u e monitoring pressures.
2. Pressure transmitter output remains constant regardless of pressure.
3. In severe cases, there will be no output.
TORQUE REQUIREMENTS:
Apply pipe compound sparingly to male pipe threads only. Avoid pipe strain on Transmitter housing by properly supporting and aligning piping. Apply
wrench to the flats of fittings only, then tighten the connection. Adequate support of piping and proper mounting of the pressure transmitter should be
made to avoid excessive shock and vibration.
TORQUE TO 125 - 150 pound inches.
CAUTION: For steam service, install a condensate loop (pigtail or steam siphon tube) between the steam line and the pressure transmitter.
Barksdale, Inc. 3211 Fruitland Avenue, Los Angeles, CA 90058-0843 (323) 589-6181, www.barksdale.com Bulletin No. 272439B 11
-01-2018
E146589
0081
Code Code Thread type
BLANK 1/4" NPT, Male - P11 G 1/2, Washer seal, Male
- P6 1/4” NPT, Female - P13 G 1/2, Washer seal, Female
- P4 1/2" NPT, Male - P3 7/16-20, with 37° Flared, Male
- P5 1/2” NPT, Female - P1 7/16-20, with 37° Flared, Female
- P10 G 1/4, washer seal, Male - P2 7/16-20, SAE #4, ORB, Male
- P12 G 1/4, Washer seal, Female - P14 7/16-20, SAE #4, ORB, Female
- P15
TYPE OF THREADS FOR PROCESS CONNECTIONS
HF4 Autoclave, 1/4” Tube, Female (9/16-18 UNF-28 THD)
Thread type
TYPE 4X
DIMENSIONS
WIRING
Current Output (4-20mA):
Voltage Output (1 5 VDC / Optional available):
Configuration with HART Device:
1. Point to Point:
2. Multi Drop:
Typical Schematic for 450X Transmitter:
Load Resistance Chart:
RETURN REQUESTS / INQUIRIES
Direct all warranty and repair requests/inquiries to Barksdale, Inc. Customer Service
Department.
Call 323-589-6181, FAX: 323-589-3463
BEFORE RETURNING ANY PRODUCT(S) TO BARKSDALE, YOU MUST OBTAIN A
RETURNED MERCHANDISE AUTHORIZATION FROM OUR CUSTOMER SERVICE
DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS).
FOR WARRANTY RETURNS, please have the following information available BEFORE
contacting Barksdale:
1. P.O. number under which the product was PURCHASED.
2. Model number of the product under warranty.
3. Repair instructions and/or specific problems you are having with the product.
4. Application information. Copyright 2018 Barksdale, Inc.
Bulletin No. 272439B 11-01-2018
PRESSURE RANGES 10k TO 30k PSI