Measuring input type : DC current / DC voltage
More output typeAnalog output / Relay / RS-485
Extraction of square root(Input : voltage, current)
Option RS-485 communication function can do 10-point linear calibration function
Signal isolation, preventing noise, filtering function : Provide safe and stable measuring
Power supply : AC 85 .. 253 V, 50 ... 60 HzAuxiliary supply output(DC 18 ... 26 V / 50 mA ) : Use for 2-wire &
3-wire transmitter
User-friendly, interactive operation interface
Panel installation, high light red LED display panel, 14.1 mm height of character, 5 digits, -9.9.9.9 ... +9.9.9.9.9,
7-segment display
Programmable, high safety & stability, fire-proof case, moisture-proof cover
Plug-in installation design for easy maintenance
Industry / Agriculture / Pottery & glass / Chemical Industry / Transportation / Technology / Energy / Eco-friendly /
Oil & gas / Water circulation system / Marine / Factory automation / Metal & steel / Cement / Pulp & paper /
Pharmaceuticals / Food & beverage
DPM02
Multifunction Signal Display Monitor
Application
Features
Signal / Meter
www.eyc-tech.com
Display
Display readout
Decimal point
Display
Accuracy
Sampling time
Response time adjustment range
Parameter setting mode
5 digits(-9.9.9.9 ... +9.9.9.9.9)
0 ... 4 place, button
Highlight red LED(Brightness can be
adjusted), digit height 14.1 mm
0.1%F.S.±1 digital
4 cycle/sec
0.5 ... 60 sec
Button
Environment
Operating environment
Storage environment
-10 ... +60°C
0 ... 95%RH(Non-condensing)
-25 ... +60°C
Electrical
Power supply / Voltage
Auxiliary power / Output
Insulation voltage endurance
Parameter memory type
Dissipated power
AC 85 ... 253 V / 50 ... 60 Hz
DC 18 ... 26 V / 50 mA
2 K Vac/1 min
FLASH
5 W
Protect
IP rating
Electric protection
IP65(Front panel)
■ Polarity protection ■ Over-voltage
Material
Case
Dimensions(HxWxD)
Cut out dimensions
Weight
ABS fire-proof class(UL94V-0)
48x96x94.45 mm
42.5x90.5 mm(+1 mm)
About 230 g
Input
Input Current0 ... 20 mA / 4 ... 20 mA
Voltage0 ... 10 V / 2 ... 10 V / 0 ... 1 V /
0.2 ... 1 V / 1 ... 5 V
Output
Analog
Relays
Communication
Analog output
Load resistance
Analog output resolution
Signal error detection
Alarm hysteresis
ON and OFF delay
Output signal error detection
Relay actuation direction
Relay capacity
Communication methods & protocol
RS-485 baud rate
Current0 ... 20 mA / 4 ... 20 mA /
20 ... 0 mA / 20 ... 4 mA
Voltage0 ... 1 V / 0.2 ... 1 V / 0 ... 5 V / 1 ... 5 V /
0 ... 10 V / 2 ... 10 V / 1 ... 0 V / 1 ... 0.2 V /
5 ... 0 V / 5 ... 1 V / 10 ... 0 V / 10 ... 2 V
CurrentRL< 500 ΩVoltage≧10 KΩ
12 bit
Yes
Display value or 0 ... 100%
0 ... 3600 sec
Yes
Upper limitHI / ALLower limitLO / AL
Max current6 A
Max voltageAC 277 V / DC 30 V
Max power1500 VA / 180 W
RS-485 Modbus RTU, master or slave
9600192003840057600115200 bps
Isolation
Power supply / Analog input / Analog output / RS-485
Certification
CE Certification
Emission EN 61326-12013
CISPR112009+A12010 Group 1 Class B
EN 61000-3-22014
EN 61000-3-32013
Immunity EN 61326-12013
 IEC 61000-4-52014
IEC 61000-4-22008  IEC 61000-4-62013
IEC 61000-4-32006+A12007+A22010
 IEC 61000-4-82009
IEC 61000-4-42012
 IEC 61000-4-112004
90.5 mm
42.5 mm
96.0 mm
48.0 mm
5.5 mm 72.0 mm 16.95 mm
94.45 mm
Specification
Dimension Installation Dimension
Signal / Meter
www.eyc-tech.com