Learn more: CarlisleIT.com/products/connectors-accessories/
» Planar design
» Machined shells
» Ferrite immobilization
» Space qualified
» Can incorporate filtering plus Transient Voltage Suppression
» Can meet DO-160 lightning requirements
CarlisleIT D-Sub & Micro-D filter connectors meet all the
requirements of Mil-PRF-24308 and Mil-PRF-83513 while
providing filtering in accordance with the attenuation curves
noted herein. Mil-PRF-24308 connectors (Standard density and
Hi-density) and Mil-PRF-83513 are manufactured in all layouts
offering maximum contact density in a minimum of space.
Both series of connectors are offered with the standard variations
in mounting hardware, standard straight or right angle contacts
and PCB, solder cup, and crimp termination.
PERFORMANCE, BENEFITS, & CERTIFICATIONINTRODUCTION
DESIGN CONSIDERATIONS
D-Sub & Micro-D Filter Connectors
Micro-D D-Sub Right AngleD-Sub
Rectangular
Mating End
Contacts
Filter Types* Electrical Environmental
Mounting
Hardware
Contact
Terminations
MIL-DTL-24308 Pin C Feed Thru Contacts Thermal Cycle Clinch Nut PC Tails
MIL-DTL-83513 Socket Pi Ground Contacts Thermal Shock Helicoil Solder Cup
C-L/L-C DWV min ____ VDC Burn-in Jack Posts Crimp
T Immersion Wire Wrap
Capacitance
Attenuation
* Maximum or Mixed Capacitance Requirement? ____pF
D-Sub & Micro-D Filter Connectors
MECHANICAL & ENVIRONMENTAL PERFORMANCE
ATTENUATION GRAPHS
Connectors are designed to meet customer specifications and the applicable MIL Specification requirements. The following are the
typical requirements for M24308 & M83513 filter connectors.
Test Description Procedure
Temperature Cycling
EIA-364-32 Condition I
Durability
500 Matings at a rate of 200 ± 100 cycles per hour
Shock
EIA-364-27, 3 Axis
Vibration
EIA-364-28 Condition IV
Fluid Immersion
EIA-364-10 Test Fluids (a) and (d)
Salt Spray
EIA-364-26 Condition B
Humidity
EIA-364-31 Method IV
Burn-in, thermal shock and thermal cycle testing available in-house
‘Pi’ Type Filter Attenuation
Frequency (MHz)
Insertion Loss (dB)Insertion Loss (dB)
11 0 100 1000
0.0
-10.0
-20.0
-30.0
-40.0
-50.0
-60.0
-70.0
PL
PM
PT
PH
PVH
‘C’ Type Filter Attenuation
Frequency (MHz)
11 0 100 1000
0.0
-10.0
-20.0
-30.0
-40.0
-50.0
-60.0
-70.0
CL
CM
CT
CH
CVH
See CarlisleIT’s line of Connectors & Accessories
products at:
CarlisleIT.com/products/connectors-accessories/
+1 (800) 458.9960