Page 1
www.sensata.com
Copyright © 2018 Sensata Technologies, Inc.
| SMALL FRAME PD SERIES (PDA, PDM)
2 TO 40 AMP PRECISION THERMAL CIRCUIT BREAKER
SPECIFICATIONS
The KLIXON® PD series thermal breakers are designed to protect wiring and meet the harshest environmental requirements. The PD series are weatherproof
sealed for protection against moisture, dust, grease, fuel vapors and other harsh environments. The PD series breakers are compact, lightweight and
designed to interrupt short circuits or overloads, and combine trip-free protection with fast response time.
Typical applications are protection of wire and cable of accessory circuits, equipment and battery protection in construction and off-road equipment, marine,
recreational vehicles (RV’s), mining, agricultural equipment and electric (hybrid) vehicles.
Features
Introduction
30VDC or 120VAC, 2 to 40 Amps
Sealed assemblies, available in manual and automatic reset options
Ignition protected
UL Recognized E36869
Calibration : 200% rated current, 77°F
(25°C)
2 to 10 amps : 20 to 150 seconds
12.5 to 40 amps : 8 to 50 seconds
Ultimate Trip At 77°F (25°C)
) Must hold 110%, must trip 138%
Endurance
Per SAE J553
Interrupt Current Capacity
Per SAE J553 and ABYC E-11
Vibration
10G MIL-STD-202 Method 204, Condition A
Mechanical Shock
MIL-STD-202 Method 213, Condition C, 100G
Salt Spray
MIL-STD-202 Method 101D
Dielectric Strength
MIL-STD-202 Method 301, 1500VAC min
Insulation Resistance
MIL-STD-202 Method 302, Condition B,100 MΩ min
Weight (with mounting nuts)
PDM : 48 grams max
PDA : 41 grams max
Page 2
www.sensata.com
Copyright © 2018 Sensata Technologies, Inc.
TRIP CURVE
DIMENSIONS
All dimensions are in inches [mm]
Approximate Time, Current Characteristics At 77°F (25°C)