DC/DC Converter
TEQ 300WIR Series, 300 Watt
High power block with excellent thermal
convection
Operating temperature -40°C to +80°
Increased shock & vibration resistance
Ultra wide 4:1 input voltage range
EN 50155 approval for railway
applications
Excellent efficiency up to 92%
Constant current output characteristic
for battery load applications
Power sharing (up to 3 pcs in parallel)
Input filter meet EN 55022, class A
Under voltage lock-out circuit
IEC 60950-1
UL 60950-1
UL 508
The TEQ 300WIR Series is a family of isolated high performance DC/DC con-
verter modules with ultra-wide 4:1 input voltage ranges which come in a
rugged, sealed metal case.
These converters are suitable for a wide range of applications, but the product
is designed particularly also for industrial applications where often no PCB
mounting is possible but the module has to be mounted on a chassis. A very
high efficiency and the overall heatsink construction allows an operating tem-
perature up to +55°C with natural convection cooling without power derating
and up to +80°C with power derating. Further features include output voltage
trimming, Remote On/Off and under voltage lockout. The ultra wide input volt-
age range and reverse input voltage protection make these converters also an
interesting solution for battery operated systems.
Models
Order Code
Output Voltage
nom.
Output Current
max.
Efficiency
typ.
TEQ 300-4812WIR
12 VDC
25'000 mA
89 %
TEQ 300-4815WIR
24 VDC
12'500 mA
92 %
TEQ 300-4816WIR
28 VDC
10'800 mA
91 %
TEQ 300-4818WIR
48 VDC
6'300 mA
92 %
TEQ 300-7212WIR
12 VDC
25'000 mA
89 %
TEQ 300-7215WIR
24 VDC
12'500 mA
91 %
TEQ 300-7216WIR
28 VDC
10'800 mA
91 %
TEQ 300-7218WIR
48 VDC
6'300 mA
92 %
Options
TEQ-MK2
- Optional DIN-Rail Clip: www.tracopower.com/products/teq-mk2.pdf
Current Splitter
- Current Line Splitter (2 incl. in every 48 Vin module): www.tracopower.com/products/current-splitter.pdf
Note
- Max. Power up to 400 W (depending on temperature and duty cycle)
www.tracopower.com
August 5, 2019
Page 1 / 4
Input Current
- At no load
48 Vin models:
30 mA typ.
110 Vin models:
20 mA typ.
Surge Voltage
48 Vin models:
100 VDC max. (1 s max.)
110 Vin models:
185 VDC max. (1 s max.)
Under Voltage Lockout
48 Vin models:
15.6 VDC min. / 16 VDC typ. / 16.8 VDC max.
110 Vin models:
33 VDC min. / 34.5 VDC typ. / 36 VDC max.
Recommended Input Fuse
48 Vin models:
25'000 mA (fast acting)
110 Vin models:
12'000 mA (fast acting)
Input Filter
Internal Common Mode Choke + Pi-Type
Input Specifications
Output Voltage Adjustment
±20% (By trim potentiometer)
Output power must not exceed rated power!
Voltage Set Accuracy
±1% max.
Regulation
- Input Variation (Vmin - Vmax)
0.2% max.
- Load Variation (0 - 100%)
0.5% max.
Ripple and Noise
(20 MHz Bandwidth)
12 Vout models:
125 mVp-p max.
24 Vout models:
250 mVp-p max.
28 Vout models:
250 mVp-p max.
48 Vout models:
350 mVp-p max.
12 Vout models:
100 mVp-p typ.
24 Vout models:
200 mVp-p typ.
28 Vout models:
200 mVp-p typ.
48 Vout models:
300 mVp-p typ.
Capacitive Load
Infinite
Minimum Load
Not required
Temperature Coefficient
±0.02 %/K max.
Start-up Time
140 ms typ.
Short Circuit Protection
Automatic recovery
Overload Protection
Constant Current Mode
Output Current Limitation
105 - 115% of Iout max.
Overvoltage Protection
125 - 140% of Vout nom.
Transient Response
- Response Time
250 µs typ. (25% Load Step)
Load Share Function
- Refer to application note
www.tracopower.com/overview/teq300wir
Load Share Accuracy
10%
Output Specifications
Safety Standards
- IT / Multimedia Equipment
IEC 60950-1
EN 60950-1
UL 60950-1
- Industrial Control Equipment
UL 508
- Railway Applications
EN 50155
- Certification Documents
www.tracopower.com/overview/teq300wir
Pollution Degree
PD 2
Over Voltage Category
OVC II
Safety Specifications
EMI Emissions
EN 50121-4 (Railway Application Signalling)
- Conducted Emissions
EN 55011 class A (internal filter)
EN 55032 class A (internal filter)
- Radiated Emissions
EN 55011 class A (internal filter)
EN 55032 class A (internal filter)
EMC Specifications
TEQ 300WIR Series, 300 Watt
All specifications valid at nominal voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
August 5, 2019
Page 2 / 4