MR Series
300 Watt
Regulated
High Voltage
DC Modules
Models from
0-1 kV DC
through
0-5 kV DC
Fully compliant with the European
harmonized EMI directive, EN50082-2,
and with the low voltage (safety)
directive, 73/23/EEC.
Features:
Air Insulated. Single printed circuit
board construction for easy access.
Air insulation for serviceability and
light weight.
Constant Voltage/Constant Current/
Current Trip Operation. Automatic
crossover from constant voltage
regulation to current control for
protection from overloads, arcs,
and shorts. Current control is user
configured for constant current
regulation or current trip.
Low Ripple. Better than 0.02% RMS
of rated voltage at full load.
Tight Regulation. Voltage regulation
better than 0.005%, line or load; current
regulation better than 0.1% from short
circuit to rated voltage.
Fast Transient Response. Less than 2
milliseconds for a 50% load transient.
Local Control and Indicator. Ten-turn
control for either voltage or current.
Power ON indicator.
Remote Interface Connections. Voltage
or current local control, voltage and
current program and monitor terminals,
current regulation/trip, TTL high voltage
enable, safety interlock terminals, +10
volt reference source, common, and
chassis ground.
Small Size and Weight. 3.375” (85.4 mm)
H x 7.25” (184.2) W x 16.00” (406) D.
Weight less than 11 pounds (5 kg.)
Output Connector and Cable. Choice
of Alden connector with unshielded
silicone wire or SHV connector with
RG-59 shielded cable.
Warranty. Standard power supplies
are warranted for three years; OEM
and modified power supplies are
warranted for one year. A formal
warranty statement is available.
Modules from 0 to 1 kV through 0 to 5 kV, 3.38" high x 7.25" wide x 16" deep.
SHV connector version shown, Alden connector available.
The MR Series…a sophisticated, medium power, high voltage power supply designed to
meet international safety approvals…is packaged as a space-saving module that avoids
the cost of expensive panels and displays. However, no compromises in performance
and operating features have been made. The result is a power supply that offers
outstanding value for a wide range of demanding applications.
Check the specs…
and compare
Designing Solutions for High Voltage Power Supply Applications
GLASSMAN HIGH VOLTAGE INC.
124 West Main Street, PO Box 317, High Bridge, NJ 08829-0317
(908) 638-3800 • Fax (908) 638-3700 • www.glassmanhv.com
GLASSMAN EUROPE Limited (UK) GLASSMAN JAPAN High Voltage Limited
+
44 1256 883007 FAX
+
44 1256 883017 +81 45 902 9988 FAX
+
81 45 902 2268
E-mail: Glassman_europe@glassmanhv.com E-mail: Glassman_japan@glassmanhv.com
©Glassman High Voltage, Inc. Printed in the U.S.A. B 12/17/2003
Specifications
(From 5% to 100% rated voltage. All
units operate down to zero output with
very slight degradation of performance.)
Input: 103-132 V RMS, 48-63 Hz single
phase, <6 A. Connector per IEC 320
with mating line cord.
Efficiency: Typically 85% at full load.
Output: Continuous, stable adjustment,
from 0 to rated voltage or current by
panel mounted 10-turn potentiometer
with 0.05% resolution, or by external
0 to 10V signals is provided. Linearity
is <1% of rated. Voltage accuracy is
0.5% of setting, 0.2% of rated.
Repeatability is <0.1% of rated.
Stored Energy: <0.5 joules.
Voltage Regulation: <0.005% for line
variations. For load variations, add
1 mV/mA.
Ripple: <0.02% RMS of rated voltage
+ 300 mV RMS.
Current Regulation: <0.1% of rated
current from short circuit to rated
voltage at any set current.
Voltage Monitor: 0 to + 10 V DC for
zero to rated voltage. Accuracy, 0.5%
of reading + 0.2% of rated voltage.
Current Monitor: 0 to + 10 V DC for
zero to rated current. Accuracy, 1%
of reading + 0.05% of rated current.
Stability: 0.01% per hour after 1/2 hour
warm-up, 0.05% per 8 hours.
Voltage Rise/Decay Time Constant:
Typically 50 ms rise or decay time
constant using TTL on/off or remote
voltage control with a minimum of
15% resistive load.
Temperature Coefficient: 0.01%/
o
C.
Ambient Temperature: -20 to +40
o
C
operating, -40 to +85
o
C storage.
Polarity: Positive or negative with
respect to chassis ground.
Protection: User-selected automatic
current regulation or current trip
protects against all overloads,
including arcs and short circuits.
Fuses, surge-limiting resistors, and
low-energy components provide
ultimate protection.
Accessories: Detachable 8-foot HV
cable (see Models chart for choice of
output connector and cable type) and
6-foot detachable line cord provided.
Remote Connections: Common,
+10V reference, interlock, current
program, current monitor, voltage
program, voltage monitor, TTL HV
enable, current regulation/trip, and
chassis ground.
External Interlock: Open off, closed on.
HV Enable/Disable: 0-1.5 V off,
2.5-15 V on.
Designing Solutions for High Voltage Power Supply Applications
GLASSMAN HIGH VOLTAGE INC.
124 West Main Street, PO Box 317, High Bridge, NJ 08829-0317
(908) 638-3800 • Fax (908) 638-3700 • www.glassmanhv.com
Options
Symbol Description
100 100 V input, rated 90-110 V RMS, 48-63 Hz.
200 200 V input, rated 180-220 V RMS, 48-63 Hz.
220 220 V input, rated 198-264 V RMS, 48-63 Hz.
400 48-420 Hz, available on standard models and options 100, 200,
and 220.
SS Slow start ramp, up to 30 seconds. Specify time.
5VC 0-5 V voltage and current program/monitor.
Models(Alden Connector)
Positive Negative Output Output Output
Polarity Polarity Voltage Current Cable
MR1P300L MR1N300L 0-1 kV 0-300 mA
MR1.5P200L MR1.5N200L 0-1.5 kV 0-200 mA
MR2P150L MR2N150L 0-2 kV 0-150 mA RG-59
MR3P100L MR3N100L 0-3 kV 0-100 mA
MR5P60L MR5N60L 0-5 kV 0-60 mA
Positive Negative Output Output Output
Polarity Polarity Voltage Current Cable
MR1P300 MRIN300 0-1 kV 0-300 mA
MR1.5P200 MR1.5N200 0-l.5 kV 0-200 mA
MR2P150 MR2N150 0-2 kV 0-150 mA Silicone wire
MR3P100 MR3N100 0-3 kV 0-100 mA
MR5P60 MR5N60 0-5 kV 0-60 mA
Models(SHV Connector)