2-31-160 / Ind us trial audib le & vis ual s ignals2-31-160 / Ind us trial audib le & vis ual s ignals
AB105STR Alarm Sounder &
Xenon Strobe
The AB105STR combines a compact high output 112dB(A) alarm sounder with
a powerful 5J Xenon strobe warning beacon.
The beaco n and sounder can be o perated from the same po wer s o urce o r co ntrolled individually.
The AB105STR Xenon beacon component features an auto matically synchro nised flash rate o f
1Hz (60 flashes per minute) as standard. The DC voltage versio ns also have us er selectable 1.5Hz
(90 flashes per minute) and do uble-strike flas h rates . The double strike flash rate can be remo tely
activated via a third wire (as can alternative alarm tones o n the horn sounder) enabling a audible
and vis ual co mmunication o f a two s tage alarm conditio n.
Features
Automatic synchronisation on multi-sounder system.
Continuously rated.
Stainless steel fixings.
Unit can be mounted using external lugs or internal BESA
compatible fixing positions.
Duplicate cable terminations (in & out for daisy-chain
installations).
Synchronised flash.
Available with multi-frequency function.
Tropicalisation available on request.
Available with custom tone configurations and frequencies.
Stage Programmable 4 stage/channel version available:
45 alarm tones
4 remotely selectable stages
Any tone can be assigned to any stage
User configurable continuous frequency tone
Ap p ro vals
Alarm sounder (A105N): EN54-3 (CPD 89/106/EEC).
Sp ecif icat io n
Sou n d e r :Sou n d e r :
Maximum output: 112dB(A)1m [103dB(A)10ft/3m]
Nominal output: 105dB(A)1m +/-3dB Tone 2 {96dB(A)10ft/3m]
No. of tones: 32 (UKOOA / PFEER compliant)
No. of stages: Alarm horn:3, Xenon Beacon (DC only):2
Double strike pattern can be remotely switched
Volume control: Max. 105dB(A); Min. 96dB(A) – Tone 2
Effective range: 60m/197ft @ 1KHz
Stage switching: Negative (Reverse polarity switching on DC units)
Beacon :Beacon :
Energy: 5 Joules (5Ws)
Flash rate: 1Hz (60 fpm)
DC units: Optionally 1.5Hz & double strike
Synchronisation: 1Hz flash rate automatically synchronised
Peak Candela: 500,000 cd – calculated from energy (J)
Eff. Intensity cd: 250 cd – calculated from energy (J)
Peak Candela: 49,788 cd* – measured ref. to I.E.S.
Eff. Intensity cd: 125 cd* – measured ref. to I.E.S.
Tube life: 70% emissions after 8 million flashes
Gen e r al :Gen e r al :
Voltages DC: 24V dc (10-30V dc); 48V dc (35-60V dc)
[DC units can use 24V ac for single stage
applications.]
Voltages AC: 24V ac; 115V ac; 230V ac
Ingress protection: IP65
Enclosure
material:
High impact UL94 V0 & 5VA FR ABS
Lens material: UV stable PC UL94 V0 FR
Bayonet lens fixing , Anti-tamper locking screw.
Cable entries: 2 x M20 clearance gland entries in side & back
Terminals: 0.5 to 1.5mm² cables.
Operating temp: -25 to +5C [-13° to +131°F]
Storage temp: -40 to +70°C [-40° to +158°F]
Relative humidity: 90% at 20° [68°F]
Weight: DC: 1.00kg/2.2Ibs AC:1.25kg/2.75Ibs
Ca nd e la m e a s ure m e nt s re p re s e nt a t iv e o fCa nd e la m e a s ure m e nt s re p re s e nt a t iv e o f
p e rf o rm a nc e wi t h c l e a r l e ns a t o p t im um vo lt a g e .p e rf o rm a nc e wi t h c l e a r l e ns a t o p t im um vo lt a g e .
SPL data +/-3dB(A). Measured at optimum voltage.
Part Co d es
Ver si on :Ver si on : Par t cod e :Par t cod e :
12V dc AB105STRDC12[x]/[y]
24V dc AB105STRDC24[x]/[y]
48V dc AB105STRDC48[x]/[y]
24V ac AB105STRAC24[x]/[y]
115V ac AB105STRAC115[x]/[y]
230V ac AB105STRAC230[x]/[y]
[x] = Enclosure
colour:
G: Grey R: Red
[y] = Lens colour: A: Amber B: Blue C: Clear
G: Green R: Red Y: Yellow
Suffix part number with ‘-P’ for stage programmable, 4 stage, 45 tone version.
Alarm So under
Ver si on :Ver si on : Vol t age:Vol tage: Cu r r e n t:Cu r r en t :
12V dc 10-14V dc 25mA*
24V dc 20-28V dc 25mA*
48V dc 42-54V dc 50mA*
115V ac 50/60Hz +/-10% 20mA
230V ac 50/60Hz +/-10% 15mA
24V ac 50/60Hz +/-10% 40mA
* current at nominal voltage on Tone 2
Xeno n Beaco n
Ver si on :Ver si on : Vol t age:Vol tage: Cu r r e n t:Cu r r en t :
12V dc 10-14V dc 500mA
24V dc 20-28V dc 250mA
48V dc 42-54V dc 175mA
115V ac 50/60Hz +/-10% 70mA
230V ac 50/60Hz +/-10% 35mA
24V ac 50/60Hz +/-10% 300mA