Technical Data Sheet
LOCTITE
®
FREKOTE FMS™
Known as FMS™
August-2014
PRODUCT DESCRIPTION
LOCTITE
®
FREKOTE FMS™ provides the following product
characteristics:
Technology Mold Release
Appearance Clear, colorless
LMS
Chemical Type Solvent Based Polymer
Odor Hydrocarbon
Cure Room temperature cure
Application Mold Sealer
Application
Temperature
13 to 35 °C
Specific Benefit High gloss finish
Easy application
Fast curing
Eliminates
Porosity/Microporosity
Seals "green" molds and
repaired areas
LOCTITE
®
FREKOTE FMS™ is formulated specifically as a
sealer for fiberglass reinforced polyester, epoxy and other
composite molds commonly used in the fiberglass molding
industry. LOCTITE
®
FREKOTE FMS™ must be used when
using green, or new, molds with microporosity and other slight
surface imperfections.
TYPICAL PROPERTIES OF UNCURED MATERIAL
Specific Gravity @ 25 °C 0.757 to 0.771
LMS
Flash Point - See SDS
GENERAL INFORMATION
This product is not recommended for use in pure oxygen
and/or oxygen rich systems and should not be selected as
a sealant for chlorine or other strong oxidizing materials.
For safe handling information on this product, consult the
Safety Data Sheet (SDS).
Mold Preparation
Cleaning:
Mold surfaces must be thoroughly cleaned and dried. All traces
of prior release must be removed. This may be accomplished
by using Frekote
®
PMC or other suitable cleaner. Frekote
®
915WB™ or light abrasives can be used for heavy build-up.
Full curing of green/new molds is highly recommended to
ensure optimal performance of the sealer.
Directions for use:
1.
Apply LOCTITE
®
FREKOTE FMS™ with a clean, lint free,
cotton wiping cloth. Wet the cloth with LOCTITE
®
FREKOTE FMS™ until it is damp but not dripping.
2.
Wipe a smooth, wet film over the entire mold surface. For
larger molds, apply LOCTITE
®
FREKOTE FMS™ to the
surface one section at a time starting at one end and
working towards the other. Using a clean cloth, wipe off
the area that was just treated to obtain a smooth thin wet
layer.
3. Allow a minimum of 15 minutes before applying next coat.
New molds require 1 to 2 coats of sealer.
4. NOTE: Changes in temperature will affect solvent dry
time. At temperatures below 18°C, waiting time between
wiping on and drying off can be slightly longer than 20
seconds. At higher then normal temperatures (greater
then 35°C) the wait time is significantly reduced and can
be as quick as 1 to 2 seconds. In these conditions it is
also advisable to reduce your wipe area to eliminate
streaking due to the increased solvent evaporation and
polymer cure times. A general guideline is to wait until the
edges of the wiped area begins to creep inwards
indicating the evaporation has just begun. Wipe from the
outside and slowly work your way towards the center.
Light hand pressure is all that is needed. No hard rubbing
required. change cloth frequently to ensure proper drying
of the mold. On small molds, allow up to 15 minutes
between coats. If one coat takes more than 15 minutes,
simply go back to starting point and begin to apply next
coat. .
5. Allow the final coat to cure for 20 minutes at 20°C.
Loctite Material Specification
LMS
LMS dated February-07, 2007. Test reports for each batch
are available for the indicated properties. LMS test reports
include selected QC test parameters considered appropriate to
specifications for customer use. Additionally, comprehensive
controls are in place to assure product quality and
consistency. Special customer specification requirements may
be coordinated through Henkel Quality.
TDS LOCTITE
®
FREKOTE FMS™, August-2014
Storage
The product is classified as flammable and must be stored in
an appropriate manner in compliance with relevant
regulations. Do not store near oxidizing agents or combustible
materials. Store product in the unopened container in a dry
location. Storage information may also be indicated on the
product container labelling.
Optimal Storage: 8 °C to 21 °C. Storage below 8 °C or
greater than 28 °C can adversely affect product properties.
Material removed from containers may be contaminated during
use. Do not return product to the original container. Henkel
cannot assume responsibility for product which has been
contaminated or stored under conditions other than those
previously indicated. If additional information is required,
please contact your local Technical Service Center or
Customer Service Representive.
Conversions
(°C x 1.8) + 32 = °F
kV/mm x 25.4 = V/mil
mm / 25.4 = inches
µm / 25.4 = mil
N x 0.225 = lb
N/mm x 5.71 = lb/in
N/mm² x 145 = psi
MPa x 145 = psi
N·m x 8.851 = lb·in
N·m x 0.738 = lb·ft
N·mm x 0.142 = oz·in
mPa·s = cP
Note:
The information provided in this Technical Data Sheet (TDS) including
the recommendations for use and application of the product are based
on our knowledge and experience of the product as at the date of this
TDS. The product can have a variety of different applications as well as
differing application and working conditions in your environment that
are beyond our control. Henkel is, therefore, not liable for the suitability
of our product for the production processes and conditions in respect
of which you use them, as well as the intended applications and
results. We strongly recommend that you carry out your own prior trials
to confirm such suitability of our product.
Any liability in respect of the information in the Technical Data Sheet or
any other written or oral recommendation(s) regarding the concerned
product is excluded, except if otherwise explicitly agreed and except in
relation to death or personal injury caused by our negligence and any
liability under any applicable mandatory product liability law.
In case products are delivered by Henkel Belgium NV, Henkel
Electronic Materials NV, Henkel Nederland BV, Henkel
Technologies France SAS and Henkel France SA please
additionally note the following:
In case Henkel would be nevertheless held liable, on whatever legal
ground, Henkel’s liability will in no event exceed the amount of the
concerned delivery.
In case products are delivered by Henkel Colombiana, S.A.S. the
following disclaimer is applicable:
The information provided in this Technical Data Sheet (TDS) including
the recommendations for use and application of the product are based
on our knowledge and experience of the product as at the date of this
TDS. Henkel is, therefore, not liable for the suitability of our product for
the production processes and conditions in respect of which you use
them, as well as the intended applications and results. We strongly
recommend that you carry out your own prior trials to confirm such
suitability of our product.
Any liability in respect of the information in the Technical Data Sheet or
any other written or oral recommendation(s) regarding the concerned
product is excluded, except if otherwise explicitly agreed and except in
relation to death or personal injury caused by our negligence and any
liability under any applicable mandatory product liability law.
In case products are delivered by Henkel Corporation, Resin
Technology Group, Inc., or Henkel Canada Corporation, the
following disclaimer is applicable:
The data contained herein are furnished for information only and are
believed to be reliable. We cannot assume responsibility for the results
obtained by others over whose methods we have no control. It is the
user's responsibility to determine suitability for the user's purpose of
any production methods mentioned herein and to adopt such
precautions as may be advisable for the protection of property and of
persons against any hazards that may be involved in the handling and
use thereof. In light of the foregoing, Henkel Corporation specifically
disclaims all warranties expressed or implied, including
warranties of merchantability or fitness for a particular purpose,
arising from sale or use of Henkel Corporation’s products. Henkel
Corporation specifically disclaims any liability for consequential
or incidental damages of any kind, including lost profits. The
discussion herein of various processes or compositions is not to be
interpreted as representation that they are free from domination of
patents owned by others or as a license under any Henkel Corporation
patents that may cover such processes or compositions. We
recommend that each prospective user test his proposed application
before repetitive use, using this data as a guide. This product may be
covered by one or more United States or foreign patents or patent
applications.
Trademark usage
Except as otherwise noted, all trademarks in this document are
trademarks of Henkel Corporation in the U.S. and elsewhere.
®
denotes a trademark registered in the U.S. Patent and Trademark
Office.
Reference 0.1
Americas
+860.571.5100
Europe
+49.89.320800.1800
Asia
+86.21.2891.8863
For the most direct access to local sales and technical support visit www.henkel.com/industrial