Release date 2017-02-28 19:20 Date of issue 2017-02-28 911107_eng.xml
PS3500-DM
1
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group USA: +1 330 486 0002 Singapore: +65 6779 9091Germany: +49 621 776 2222
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
PS3500 Diagnostic Module
Zone 2/Div. 2
Diag. Bus
(HART)
Alarm relay
-+
-+
Internal Bus
Diagnosis/Alarm
NC C NO
U
U
L
N
Earth
-
+
-
+
-
+
L
N
Earth
L
N
Slot 5
Slot 3
Slot 1
Slot 5
Slot 3
Slot 1
Earth
Secondary
(24 V DC)
Primary
(Line power)
Connection
Assembly
Real-time input and output power monitoring
Diagnostics and fault indication
Modular and hot swappable
Configurable alarms
R/S 485 HART communication
Asset management integration - EDDL/DTM
ATEX, IECEx, and cULus approvals for Div 2/Zone 2
Function
Having an advanced warning of a potential power failure could
eliminate long hours of downtime and lost revenue. The
diagnostic module continuously monitors the health of the
PS3500 power supplies.
As part of the PS3500 power supply system, the diagnostic
module monitors the input, internal, and output parameters.
The diagnostic module displays values of various
measurement points along with warning and alarm messages
for out-of-tolerance values.
Features
Release date 2017-02-28 19:20 Date of issue 2017-02-28 911107_eng.xml
Technical data PS3500-DM
2
Refer to "General Notes Relating to Pepperl+Fuchs Product Information".
Pepperl+Fuchs Group USA: +1 330 486 0002 Singapore: +65 6779 9091Germany: +49 621 776 2222
www.pepperl-fuchs.com pa-info@us.pepperl-fuchs.com pa-info@de.pepperl-fuchs.com pa-info@sg.pepperl-fuchs.com
Interface
Type diagnostic bus: RS 485
Output
Rated voltage U
n
90...250 V AC, 44 ... 66 Hz; 90 ... 300 V DC
Rated current I
n
100 mA max
Fault signal Form C Relay
50 V DC @ 0.6 A
30 V DC @ 2 A
Galvanic isolation
Input/Output 4.25 kV DC
Field circuit/control circuit Primay to Diagnostic Module Isolation: 4.25 kVDC
External RS485 to primary isolation: 4.25 kVDC
Internal RS485 to primary isolation: 4.25 kVDC
Secondary to Diagnostic Module: 2.12 kVDC
External RS485 to secondary isolation: 2.12 kVDC
Internal RS485 to secondary isolation: 2.12 kVDC
Indicators/settings
Display elements LCD Status Screen
Diagnostic Module LED
Primary (AC Input) Monitors LED
Secondary (DC Output) Monitors LED
Power Supply Module LED
Directive conformity
Electromagnetic compatibility Refer to DoC for all directives and standards met.
Conformity
Electromagnetic compatibility NE 21:2006
Degree of protection IEC 60529
Shock resistance EN 60068-2-27
Vibration resistance EN 60068-2-6
Ambient conditions
Ambient temperature -20 ... 60 °C (-4 ... 140 °F)
Storage temperature -40 ... 85 °C (-40 ... 185 °F)
Relative humidity < 95 % , non-condensing
Shock resistance 15 g , 11 ms
Vibration resistance 1 g , 58 ... 150 Hz
Mechanical specifications
Connection type motherboard specific
Housing material Powder Coated, 1010 Cold Rolled Steel
Degree of protection IP20
Mass approx. 1.16 kg (2.56 lbs)
Dimensions 134 x 33 x 268 mm (5.3 x 1.3 x 10.6 inch)
Data for application in connection
with hazardous areas
Certificate DEMKO 12 ATEX 1103387X
Marking ¬ II 3G Ex ic nA nC IIC T4 Gc
International approvals
UL approval cULus Listed
E230669
E350173
Approved for Class I/Div 2, ABCD
Class I, Zone 2, Grp IIC T4
IECEx approval IECEx UL 13.0082X
Ex nA nC IIC T4 Gc
General information