Instruction manual
Rack Mount Adapter KRA1-PWX HALF SINGLE / KRA1-PWX HALF PAIR
This product is a rack mount adapter for attaching one or two Kikusui PWX Series Regulated DC Power Supplies to a rack.
• KRA1-PWX HALF SINGLE (1 unit): This can be used with JIS millimeter racks and EIA inch racks.
• KRA1-PWX HALF PAIR (2 units): This can be used with JIS millimeter racks and EIA inch racks.
Components
Check that all parts are included and that they are not damaged. If any of the parts are damaged or missing, contact your Kikusu i
agent or distributor.
Assembly
Carry out the procedure below to attach the adapter to the PWX Series and mount it on the rack.
1 Remove the rubber feet for the bottom of the PWX Series.
2 Attach the parts using the included screws of the PWX Series.
■ When attaching one power supply to a rack
Use #10-32 screws to attach the blank panel to the power supply. Use M4 screws to attach the handles and the rack mount
brackets to the power supply.
No. Parts Code Description
Quantity
SINGLE PAIR
1 B9-000-168 Blank panel PWX 1U 1
─
2 B9-000-167 Support board
─
1
3 B9-000-170 Rack mount bracket (R) KRB1-PWX (R) 1
4 B9-000-171 Rack mount bracket (L) KRB1-PWX (L) 1
5 E6-000-027 Handle 2
6 M2-101-008 Support board screw (M3x6)
─
4
7 M2-101-015 Handle and Rack mount bracket screw (M4x8) 8
8 M3-112-043 Rack mount screw (M5x14) 4
9 M2-110-006 Blank panel screw (#10-32x3/ 8) 3
─
10 M5-100-005 Blank panel washer (M5) 3
─
11 M5-101-005 Blank panel spring washer (M5) 3
─
Rubber foot (4 locations)
Screw (M3)
(4 locations)
Loosen the screws to remove the
rubber feet (in four locations).
M4 screw (4 locations)
M4 screw (4 locations)
Rack mount bracket (L)
Rack mount bracket (R)
M5 spring washer (3 locations)
#10-32 screw (3 locations)
M5 washer (3 locations)
Blank panel
Handle (2 locations)