Instruction manual
Terminal Unit
TU01-PWR-01
Part No. Z1-006-960, IB033911
Nov 2018
This terminal unit is used to convert the 20-pin J1 connector and 6-pin J2 connector of the
Kikusui PWR-01 Series Regulated DC Power Supply into the 26-pin J1 connector of the PAS or
PWR Series Regulated DC Power Supply.
This product makes it easy to transfer the external control of the PAS or PWR series to the
PWR-01 Series.
It cannot be used for parallel operation or series operation.
Before you use the product, thoroughly read the warnings and precautions that are written in
the series series
Regulated DC Power Supply operation manual. Connect this product only to
a PWR-01 series.
Components
Check that all parts are included and that they are not damaged. If any of the parts are
damaged or missing, contact your Kikusui agent or distributor.
PWR
800W model example
PWR-01
800W model example
PAS
350W type
800W type example
J1
J2
20 pin connector cable
(attached to the TU01-PWR-01)
6 pin connector cable
(attached to the TU01-PWR-01)
TU01-PWR-01
20 pin
J1 Connector
6 pin
J2 Connector
26 pin J1 Connector
26 pin
Connector
26 pin J1 Connector
26 pin connector cable
26 pin connector cable
Controller
Controller
Instruction manual
(This manual, 1 pc.)
TU01-PWR-01 (1 pc.)
Part Names and Functions
TU01-PWR-01 Specifications
Name Function
J1 connector MIL 26 pin connector (Controller side)
J2 connector 10 pin connector (PWR-01 series J1 side)
J3 connector 6 pin connector (PWR-01 series J2 side)
Environment Installation location Indoors, at a height of up to 2 000 m
Operating Temperature
and Humidity
0 °C to 50 °C (32 °F to 104 °F), 20 %rh to 85 %rh (no condensation)
Storage Temperature and
Humidity
-10 °C to 60 °C (14 °F to 140 °F), 90 %rh or less (no condensation)
Dimensions 66.5 mm x 66.5 mm x 28 mm (2.62 inch x 2.62 inch x 1.10 inch)
Length: Approx. 270 mm (10.63 inch
)
Weight Approx. 110 g (0.24 lb.)
J1 Connector
J2 Connector
J3 Connector
To J1 Connector
For PWR-01
To Controller
To J2 Connector
For PWR-01
Hook
Hook
Polarity Slot