3933 US Route 11
Cortland, NY 13045
Telephone: (607) 753-6711
Facsimile: (607) 758-3659
www.intertek.com
Page 1 of 2
This report is for the exclusive use of Intertek’s Client and is provided pursuant to the agreement between Intertek and its Client. Intertek’s responsibility and liability are
limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, ot her than to the Client in accordance with the agreement, for any loss,
expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of
the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations
and test results in this report are relevant only the sample tested. This report by itself does not imply that the material, product or service is or has ever been under an
Intertek certification program.
Intertek Testing Services NA, Inc.
July 24, 2015 Test report number 102193693CRT-001d
Project number 102193693-311
Nexans Cabling Solutions
Alsembergsesteenweg 2, b3
B-1501 Buizingen
BELGIUM
3179412CRT-001b
TEST:
Electrical performance testing of a cabling configuration to the standard requirements of ISO/IEC 11801 for
Class E permanent link.
STANDARD USED:
ISO/IEC 11801 Information Technology - Generic cabling for customer premises, Edition 2.2, dated June
2011.
SECTIONS USED:
Annex A, Balanced permanent link and CP link performance of ISO/IEC 11801
AUTHORIZATION:
The project was authorized by Ms. Nancy Declerck, representing the client, Nexans Cabling Solutions, with
signed quotation number 500602455.
SAMPLE DESCRIPTION:
The client supplied a 3-connector permanent link as illustrated below. The samples were received on July 1,
2015 and were production samples in undamaged condition.
Component Id
Manufacturer Description Part number
1, 3 Nexans LANmark-6 Evo Snap-In Connector
Cat 6 Unscreened
N420.660
2 Nexans LANmark-6 U/UTP 23 AWG Cat 6
350 MHz LSZH
N100.607
4 Nexans LANmark-6 Patch Cord Cat 6
Unscreened LSZH
N116.P1A100OK
5 Nexans LANmark-6 Evo Snap-In Connector
Cat 6 Unscreened Stranded Wire
N420.661
Nexans Cabling Solutions Test report number 102193693CRT-001d
July 24, 2015
Page 2 of 2
Intertek Testing Services NA, Inc.
EQUIPMENT LIST:
The following equipment was employed in conducting the tests.
Equipment used
Model
number
Control
number
Calibration
date
Calibration
due date
Fluke Networks Cable Analyzer DTX-1800 N1134 12/31/2014 12/31/2015
Temperature humidity meter OM-EL-USB-2-LCD H243 1/22/2015 1/22/2016
DATE OF TEST:
July 6, 2015
TEST REPORT REVISION HISTORY:
First Issue: July 24, 2015 Original document
RESULTS: See appendix A for the test results.
CONCLUSION:
The 3-connector permanent link, as previously described and supplied by the client, was tested in
accordance with the standard referred to on page 1, and did comply with the indicated applicable
transmission requirements. The testing was performed at Intertek located in Cortland, New York.
The procedures and requirements were taken from the standard referred to on page 1.
Reviewed and Approved By:
Antoine Pelletier
Project Engineer
Global Cabling Products Testing
John Cash
Associate Engineer
Global Cabling Products Testing