PARAMETER UNITS
Turns Ratio 1 : 1 +
1%
Line Impedance 135
Inductance (Line Side) 200 Min mH
Leakage Inductance 10 kHz - 1VRMS 60 Max. µH
Primary DC Resistance 18.2 Typ.
Secondary DC Resistance 18.2 Typ.
Frequency Response 1.0 Typ. dB
100 Hz - 112 kHz
Insertion Loss @ 10kHz 1.25 Typ. dB
Isolation (HI-POT) 1875 V
RMS
Primary DC 0 mA
Return Loss @ 100 Hz - 100 kHz 15 Typ. dB
Longitudinal Balance 200 - 1000 Hz 40 Typ. dB
15 kHz 35 Typ. dB
Interwinding Capacitance 65 Max. pF
10 kHz - 1 VRMS
4/15/98
Physical Dimensions in inches (mm)
SCHEMATIC DIAGRAM:
T-997NC
DDS Aplications
Pulse Transformers
Designed to meet the requirements
of Bellcore TR-NWT-000499,
Synchronous Digital Data
Interface-64 Kbps and Subrates
Recomended for use with level
one LXT400 & LXT456
Custom versions of this
transformer are available.
A Surface Mount version of this
transformer is available
Compatible with Level One
transceiver ICs
1
3
5
10
8
6
SecondaryPrimary
Pin Diameter is 0.025 (0.64)
.100
(2.54)
TYP.
.210
(5.33)
TYP.
.525
(13.34)
MAX.
.550
(13.97)
MAX.
.536
(13.61)
MAX.
.400
(10.16)
TYP.
1
2
3
4
5
10 9 8
76
Bottom
View
PIN POSITION GRID 0.100 (2.54)
HOLES FOR BOBBIN PINS