For more Information
please call
1-800-Belden1
General Description:
14 AWG solid bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond®
IV quad shield (100% coverage), PVC Jacket.
Usage (Overall)
Suitable Applications: RG-11/U Type
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1 14 Solid BCCS - Bare Copper Covered Steel 1.6256
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
Gas-injected FPE - Foam Polyethylene 7.112
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid AL - Aluminum 60
3 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 10.338 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +80°C
Bulk Cable Weight: 87.804 Kg/Km
Max. Recommended Pulling Tension: 1370.046 N
Min. Bend Radius/Minor Axis: 114.300 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL2R, CMR
CEC/C(UL) Specification: CMG
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2000/53/EC (ELV): Yes
Page 1 of 3 01-30-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3094A Coax - ControlBus™ Quad Shielded Coax
EU Directive 2000/53/EC (ELV): Yes
EU Directive 2002/95/EC (RoHS): Yes
EU RoHS Compliance Date (mm/dd/yyyy): 01/01/2004
EU Directive 2002/96/EC (WEEE): Yes
EU Directive 2003/11/EC (BFR): Yes
CA Prop 65 (CJ for Wire & Cable): Yes
MII Order #39 (China RoHS): Yes
RG Type: 11/U
Flame Test
UL Flame Test: UL1666 Riser
CSA Flame Test: FT4
Plenum/Non-Plenum
Plenum (Y/N): No
Plenum Number: 3095A
Surface Printing (Overall)
Surface Printing: CONTROLBUS(R) BY BELDEN - 3094A RG-11 TYPE 75C QUAD SHIELD
E108998 1C14 (UL) CL2R OR CMR OR C(UL) CMG
Electrical Characteristics (Overall)
Nom. Characteristic Impedance:
Impedance (Ohm) Tolerance (Ohms)
75 ± 3
Nom. Inductance:
Inductance (µH/m)
0.318257
Nom. Capacitance Conductor to Shield:
Capacitance (pF/m)
53.1522
Nominal Velocity of Propagation:
VP (%)
82
Nominal Delay:
Delay (ns/m)
3.9372
Nom. Conductor DC Resistance:
DCR @ 20°C (Ohm/km)
36.091
Nominal Outer Shield DC Resistance:
DCR @ 20°C (Ohm/km)
4.9215
Nom. Attenuation:
Freq. (MHz) Attenuation (dB/100m)
1 0.52496
2 0.59058
5 0.85306
10 1.24678
20 1.80455
50 2.72323
100 3.83877
200 5.2496
Page 2 of 3 01-30-2019
Detailed Specifications & Technical Data
METRIC MEASUREMENT VERSION
3094A Coax - ControlBus™ Quad Shielded Coax