For more Information
please call
1-800-Belden1
General Description:
14 AWG solid bare copper-covered steel conductor, gas-injected foam polyethylene insulation, Duobond®
IV quad shield (100% coverage), PVC Jacket.
Usage (Overall)
Suitable Applications: RG-11/U Type
Physical Characteristics (Overall)
Conductor
AWG:
# Coax AWG Stranding Conductor Material Dia. (mm)
1 14 Solid BCCS - Bare Copper Covered Steel 1.6256
Total Number of Conductors: 1
Insulation
Insulation Material:
Insulation Material Dia. (mm)
Gas-injected FPE - Foam Polyethylene 7.112
Outer Shield
Outer Shield Material:
Layer # Outer Shield Trade Name Type Outer Shield Material Coverage (%)
1 Duofoil® Tape Bonded Aluminum Foil-Polyester Tape-Aluminum Foil 100
2 Braid AL - Aluminum 60
3 Duofoil® Tape Aluminum Foil-Polyester Tape-Aluminum Foil 100
4 Braid AL - Aluminum 40
Outer Jacket
Outer Jacket Material:
Outer Jacket Material
PVC - Polyvinyl Chloride
Overall Cable
Overall Nominal Diameter: 10.338 mm
Mechanical Characteristics (Overall)
Operating Temperature Range: -30°C To +80°C
Bulk Cable Weight: 87.804 Kg/Km
Max. Recommended Pulling Tension: 1370.046 N
Min. Bend Radius/Minor Axis: 114.300 mm
Applicable Specifications and Agency Compliance (Overall)
Applicable Standards & Environmental Programs
NEC/(UL) Specification: CL2R, CMR
CEC/C(UL) Specification: CMG
EU Directive 2011/65/EU (ROHS II): Yes
EU Directive 2000/53/EC (ELV): Yes